2.3 SYSTEM PIPING
disconnect for servicing the unit and for vibration isolation. As
the fan is typically outside of the building thermal boundary
and is venting to the outside, installation of insulation around
the fan is not required.
2.4 ELECTRICAL CONNECTION
Connect wiring with wire nuts provided, observing proper
connections (See Section 1.10). Note that the fan is not
intended for connection to rigid metal conduit.
Fan Wire
Connection
Green
Ground
Black
AC Hot
White
AC Common
2.5 VENT MUFFLER (optional)
normally installed at the end of the vent pipe.
2.6 OPERATION CHECKS & ANNUAL
SYSTEM MAINTENANCE
______ Verify all connections are tight and leak-free.
______ Ensure the RP / RPc Series Fan and all ducting are secure and vibration-free.
______ Verify system vacuum pressure with manometer. Ensure vacuum pressure is within normal
operating range and less than the maximum recommended operating pressure.
(Based on sea-level operation, at higher altitudes reduce by about 4% per 1000 feet)
(Further reduce Maximum Operating Pressure by 10% for High Temperature environments.)
______ Verify Radon levels by testing to EPA Protocol and applicable testing standards.