RadonAway RP140 Installation instructions manual - page 7
IN020 Rev T 0217
7
3 Saber Way, Ward Hill, MA 01835 | radonaway.com
Typical CFM Vs. Static Pressure “WC
0”
.25”
.5”
.75”
1.0”
1.25”
1.5”
1.75”
2.0”
RP140/140c
135
103
70
14
-
-
-
-
RP145/145c
166
146
126
104
82
61
41
21
3
RP260/260c
251
200
157
117
70
26
-
-
-
RP265/265c
334
291
247
210
176
142
116
87
52
RP380/380c
497
401
353
281
220
176
130
80
38
Model
Size
Weight
Inlet/Outlet
L.2
RP140/140c
8.5”H x 9.7” Dia.
5.5 lbs
4.5”OD (4.0” PVC Sched 40 size compatible)
25
RP145/145c
8.5”H x 9.7” Dia.
5.5 lbs
4,5” OD
15
RP260/260c
8.6”H x 11.75” Dia.
5.5 lbs
6.0” OD
48
RP265/265c
8.6”H x 11.75” Dia.
6.5 lbs
6.0” OD
30
RP380/380c
10.53”H x 13.41” Dia.
11.5 lbs
8.0” OD
57
Model
Power Consumption
120VAC, 60Hz, 1.5 Amp Maximum
Maximum Recommended Operation Pressure*
(Sea Level Operation)**
RP140/140c
15 - 21 watts
0.7” WC
RP145/145c
41 - 72 watts
1.7” WC
RP260/260c
47 - 65 watts
1.3” WC
RP265/265c
91 - 129 watts
2.2” WC
RP380/380c
95 - 152 watts
2.0” WC
L.2 = Estimated Equivalent Length of Rigid Metal Ducting resulting in .2” WC pressure loss for Duct Size listed. Longer Equivalent Lengths
can be accommodated at Flows Lower than that at .2” WC pressure loss (see CFM Vs Static Pressure “WC Table).
Recommended Ducting: RP/RPc Series Fans (excluding RP380/380c), 3” or 4” Schedule 20/40 PVC Pipe;
RP380/RP380c, 6” Schedule 20/40 PVC Pipe
PVC Pipe Mounting: If used for Ventilation, use 4”, 6” or 8” Rigid or Flexible Ducting.
Mount on the duct pipe or with optional mounting bracket.
Storage Temperature Range: 32-100 degrees F
Thermal Cutout:
Continuous Duty
Class F Insulation (RP140/RP140c Class B)
Thermally Protected Manual Reset
3000 RPM
Rated for Indoor or Outdoor Use
*Reduce by 10% for High Temperature Operation **Reduce by 4% per 1000 ft. of altitude.
The following chart shows fan preformance for the RP / RPc Series Fans:
RP140/140c
130
o
C (266
o
F)
RP145/145c
150
o
C (302
o
F)
RP260/260c
150
o
C (302
o
F)
RP265/265c
150
o
C (302
o
F)
RP380
150
o
C (302
o
F))