Note: Start times are displayed in chronological
order. If a start time is deleted from the order by
setting it to OFF, all later start times are automati-
cally moved down one start time number. When
a start time is added to any start time number,
the controller automatically reorganizes the times
so that times appear in chronological order. This
reorganizing only occurs after the dial has been
moved off the WATERING START TIMES posi-
tion.
6.
If you want to set additional start times, press
MAN START/ADV to toggle back to the left
side of the display and the next available
start time number. Set the next start time in
the same fashion as the first.
7.
Return the dial to AUTO. The controller re-
turns to the time of day.
Step five:
Setting programs to stack or overlap
You can set a program to stack (run one at a
time) or overlap (run simultaneously). The ESP-
MC can run up to nine valves simultaneously.
The default setting is to stack all programs. To
set programs to stack or overlap:
1.
Rotate the dial to PROGRAM OVERLAP.
The display shows the program, and STACK
or OVERLAP.
2.
If the program you want is not displayed,
press PGM until it is.
3.
Use the arrow keys to set the program to ei-
ther STACK or OVERLAP.
4.
Return the dial to AUTO. The controller re-
turns to the time of day display.
Step six: Setting the MV/PUMP start
The ESP-MC has two master valve terminals on
its circuit board. MV2 (master valve 2) is enabled
when any station operates. MV1 (master valve 1)
can be enabled or disabled for each individual
station.
PGM