Rain Bird TI-DM200 Troubleshooting Manual - - 10 -

Other manuals for TI-DM200: Operating Instructions
Manual is about: Digital Multimeter

Summary of TI-DM200

  • Page 1

    Ti-dm200 digital multimeter troubleshooting guide rb.Dm200.Tguide.Mech 2/3/03 10:18 am page 1.

  • Page 2: - 2 -

    - 2 - table of contents troubleshooting guide . . . . . . . . . . . . . . . . .3 1. Troubleshooting at the controller voltage check of 120v input . . . . . . . . . . . . . . .5 voltage check of transformer: . . . . . . . . . . . . . .6 resistance check of fuse: . . . . . . . . . . . . . . . . .7 vol...

  • Page 3: Troubleshooting Guide

    Troubleshooting guide for zone irrigation systems this troubleshooting guide will assist you in the location of fault in an irrigation control system related to power supply or valve control wires. There are corresponding instructions on how to use the test tool to accomplish steps that require thei...

  • Page 4: Step 5

    Step 5 (continued from previous page) use the instructions provided to test any valves (or solenoids or wires) on the stations with faulty resistance measurements (page 10 of this guide). A rain bird tone and probe kit (model ti-tpk) or a rain bird wire sorter (model ti-ws6) can be helpful in locati...

  • Page 5: Voltage Check Of 120V Input

    Voltage check of 120v input for standard outlets: 1) insert probes into outlet one at a time. 2) observe voltage reading on ti-dm200 display. 3) remove probes from outlet for hard wired controllers: 1) turn power off at main circuit breaker. 2) disconnect the wire nuts inside of the controller where...

  • Page 6: - 6 -

    - 6 - voltage check of transformer 1) hold one probe to each of the power lines that run into the terminal strip from the transformer. Be careful not to touch the probes together. 2) check the reading on your multimeter. Acceptable range: 24-28v (ac) set meter to 200v (ac) probe connections black co...

  • Page 7: - 7 -

    - 7 - resistance check at fuse 1) remove cover of controller. 2) remove each fuse to test it. 3) touch one probe to each side of the fuse. 4) check the reading on your multimeter. Acceptable range: very low or zero (ohms): ok. A high value or over-range indication (ol) indicates a bad fuse. Set mete...

  • Page 8: Voltage Check At Battery

    Voltage check at battery 1) remove cover from the controller and remove the dc battery. 2) insert black and red test leads into com and the proper v terminal (1.5vdc and 9vdc depending on the type of battery). 3) place selector switch into the 1.5v or 9v battery test position. 4) touch one probe to ...

  • Page 9: - 9 -

    Voltage check of station output 1) check to see if a rain sensor or other shut-off device is connected to the controller. If so, disable or disconnect the sensor before performing further troubleshooting. 2) remove cover of controller to expose terminal strip. 3) turn controller to manual mode and a...

  • Page 10: - 10 -

    Resistance check of each station caution: turn controller off remove cover of controller to expose terminal strip. 1) touch (insert) one probe to the terminal labeled com (for common). 2) touch the other probe to the terminal of the station (or mv) to be checked. 3) check the reading on your multime...

  • Page 11: Voltage Check of Each Valve

    Voltage check of each valve 1) at the controller, turn on the station of the valve to be tested. 2) touch each probe to an exposed part of each of the two splice wires leading into the solenoid. If it is easier, disconnect the solenoid and just check the voltage drop across the two wires coming from...

  • Page 12: Voltage Check of Pump Relay

    Voltage check of pump relay 1) at the controller, turn on the station or master valve (mv) that controls the pump relay to be tested. 2) at the pump relay, expose a part of each of the two wires coming out of the relay. 3) touch a probe to each of the exposed wires. 4) check the reading on your mult...