Level 2 PROGRAMMING (OPTIONAL SETTINGS)
CAUTION: DO NOT CHANGE LEVEL 2 SETTINGS WITHOUT CONSULTING RAINFRESH TECHNICIAN
(1-800-667 8072). Wrongly changing the settings can result in malfunction of the unit.
NOTE : Under normal use there is no need to change the settings under level 2 programming. You can, however,
change the default settings if required.
When the Level 2 Master Programming Mode is entered, all available option setting displays may be viewed and set
as needed. Depending on current option settings, some parameters cannot be viewed or set.
To change any setting under level 2 programming
-
press the “” key and the value flashes
-
press the “ or ” keys to change the value
-
press the “” key again to accept value
-
press the “ ” key to advance to the next value
The following chart indicates choices and default settings. Note: Default settings are indicated in bold letters
Use same programming method as you used in level 1 to advance and/or change values.
Bold letters indicate default settings
Parameter
Option 1
Option 2
Option 3
Option 4
Comments
1
SYSTEM
LANGUAGE
English (√)
Spanish
French
Set to French if desired. Spanish
not enabled
2
VALVE
OPERATION
Softener
Filter
Iron
Filter (√)
Leave at default setting
3
REGENERATION
MODE
Meter
Delayed
Meter
Override
Calendar
Clock (√)
Meter
Immediate
Leave at default setting
4
REGENERATION
TIME
12:00 AM
(√)
The unit is factory set to regeneration at 12:00 AM on the day of
regeneration. You can change to another time if desired.
5
CAPACITY
CALCULATION
Manual
(√)
Automatic
Leave at default setting
6 REGENERATION
DAYS
3 Days (√)
Leave at default setting. Before changing this value, contact Rainfresh
7
BACKWASH
15 (√)
Leave at default setting
8
BRINE/RINSE
45 (√)
Leave at default setting
9
RAPID RINSE
00 (√)
Leave at default setting (zero)
10 REFILL
00 (√)
Leave at default setting (zero)
11
RESTORE DEFAULT
NO (√)
Leave at default. Change only if you want to re-start programming from start
Press “ ” (MENU) for 3
seconds to unlock screen.
JAN/21/2015
05:27 PM
The display will read “Press MENU
Key for 3 sec to unlock”.
After 3 seconds, the display will
beep confirming unlock
PRESS MENU KEY
3 SEC TO UNLOCK
SYSTEM LANGUAGE
ENGLISH
Press and hold “
” together
for three seconds to enter Level
Two Master Programming.