RAIS 2:1 Instructions For Installation, Use And Maintenance Manual

Other manuals for 2:1: User Manual
Manual is about: wood burning stove

Summary of 2:1

  • Page 1

    English rais - manual for rais 2:1 1 april 2014 instructions for installation, use and maintenance rais 2:1 important information on first lighting the stove you must be careful not to touch the painted surfaces and it is most important that the door is kept slightly ‘ajar’ in order for the door sea...

  • Page 2

    English rais - manual for rais 2:1 2 april 2014.

  • Page 3

    English rais - manual for rais 2:1 3 april 2014 revision : date : 2011 introduction ………………………………………………………….. 4 warranty …………………………………………………….………….. 4 specifications ………………………………………………………….. 5 convection ………………………………………………………………. 6 installation instructions ………………………………….……… 7 chimney ………………………………………...

  • Page 4

    English rais - manual for rais 2:1 4 april 2014 a rais wood burning stove is more than just a heat source: it also shows that you care about design and quality in your home. To make the most of your wood burning stove it is important that you read the manual thoroughly before installing and using it...

  • Page 5

    English rais - manual for rais 2:1 5 april 2014 2:1 nominal output (kw): 6 min. / max. Output (kw): 3-9 heating area (m 2 ): ca. 60-135 size, width/depth/height (mm): 807 / 474 / 909 without socket combustion chamber width/depth/height (mm). 500 / 244 / 374 recommended amount of wood when fuelling (...

  • Page 6

    English rais - manual for rais 2:1 6 april 2014 convection rais stoves are convection stoves. This means that the stove’s back and side panels are not over-heated. Convection means that there is a circulation of air, which ensures that the heat is distributed more evenly throughout the entire room. ...

  • Page 7

    English rais - manual for rais 2:1 7 april 2014 installation instructions the following pages give instructions for the safe and proper installation of this heating appliance in the uk. These instructions cover the basic principles of installation, although some details may need slight modification ...

  • Page 8

    English rais - manual for rais 2:1 8 april 2014 chimney the chimney is the driving force which makes the stove function. In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure the correct draught of 14 to 18 pa, so as to clear the products of combustion and ...

  • Page 9

    English rais - manual for rais 2:1 9 april 2014 if it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternatively a draught stabiliser should be fitted. The adjustable flue damper should not close off the flue entirely, but should in its closed posi...

  • Page 10

    English rais - manual for rais 2:1 10 april 2014 installation it is prohibited to carry out unauthorised alterations to the stove. There must be plenty of fresh air in the room where the stove is being installed, in order to ensure proper combustion. Note that any mechanical exhaust ventilation - e....

  • Page 11

    English rais - manual for rais 2:1 11 april 2014 installation of stove: note ! A decision must be made concerning the positioning of the inlets and outlets of the convection system. Discolouration of the wall above the doors and the convection air outlets may occur due to convected hot air. Rais can...

  • Page 12

    English rais - manual for rais 2:1 12 april 2014.

  • Page 13

    English rais - manual for rais 2:1 13 april 2014.

  • Page 14

    English rais - manual for rais 2:1 14 april 2014 insulation ability such as aqua panel ( coefficient of thermal conductivity 0.36 w/mk ) or better. Please use metal stud..

  • Page 15

    English rais - manual for rais 2:1 15 april 2014.

  • Page 16

    English rais - manual for rais 2:1 16 april 2014 t h e t w o r o w s o f b ri c k s b e n e a th t h e s to v e i s l im it e d to a m a x d e p th o f 7 5 m m.

  • Page 17

    English rais - manual for rais 2:1 17 april 2014.

  • Page 18

    English rais - manual for rais 2:1 18 april 2014 installation distances for non combustible wall we recommend a minimum distance to non combustible material of 50mm ( f ) for cleaning considerations. Using uninsulated flue pipe, the minimum distance to a combustible wall must be 450mm or 225mm if th...

  • Page 19

    English rais - manual for rais 2:1 19 april 2014 for the installer finally before firing the stove for the first time a check should be made to ensure that the assembly and stove installation has been satisfactory and that there are no leaks in any seals in the appliance and appliance connections to...

  • Page 20

    English rais - manual for rais 2:1 20 april 2014 only use recommended fuels the following table shows the calorific value of different types of wood, which have been stored for 2 years and which have a residual moisture of 15 - 17%. Wood kg dry wood pr m 3 compared to beech/oak hornbeam 640 110% bee...

  • Page 21

    English rais - manual for rais 2:1 21 april 2014 drying and storage drying wood takes time: proper air drying takes approximately 2 years. Here are some tips: store the wood sawn, split and stacked in an airy, sunny place, which is protected against rain (the south side of the house is particularly ...

  • Page 22

    English rais - manual for rais 2:1 22 april 2014 control if the ash is white and the walls in the combustion chamber are soot free after the stove has been used, the air regulation was set correctly and the wood was sufficiently dry. Using the wood burning stove when using the rais 2:1, it is import...

  • Page 23

    English rais - manual for rais 2:1 23 april 2014 first usage a careful start pays off. Start with a small fire, so that the wood burning stove can get accustomed to the high temperature. This gives the best start and any damage is avoided. Be aware that a strange but harmless odour and smoke concoct...

  • Page 24

    English rais - manual for rais 2:1 24 april 2014 lighting and fuelling to light the stove, use alcohol briquettes or similar, as well as approximately 2kg of firewood, split into kindling sticks. Set the air damper to the fully open position. It is important that the air-kit system airtight flap, lo...

  • Page 25

    English rais - manual for rais 2:1 25 april 2014 when the flames are clear, after approximately 5-10 minutes, close the door. Damper - see adjustment of the damper. After approximately 10-20 minutes, when you have a good bed of glowing embers, add 2-3 pieces of wood. Leave the door ajar until the fi...

  • Page 26

    English rais - manual for rais 2:1 26 april 2014 cleaning and care the wood burning stove and the chimney must be serviced by a chimney sweep twice a year. During cleaning and care, the stove must be cold. If the glass is sooty: - moisten a piece of paper or newspaper, dip it in the ash, and rub the...

  • Page 27

    English rais - manual for rais 2:1 27 april 2014 the flue ways consist of a baffle plate and a smoke conductor above. Both parts are made of vermiculite. Handle these parts carefully. Lift the baffle plate a little and push towards one of the sides. Remove the baffle plate by lifting it upwards and ...

  • Page 28

    English rais - manual for rais 2:1 28 april 2014 problem solving smoke spillage around door: - could be due to too low draught in the chimney - check if the flue or chimney is blocked - check if a extraction hood is switched on; if it is, switch it off and open a window/door in the proximity of the ...

  • Page 29

    English rais - manual for rais 2:1 29 april 2014 accessories and spare parts if spare parts other than those recommended by rais are used, the warranty is voided. All replacement spare parts can be purchased from your rais distributor / stockist. See the following spare parts diagrams for the indivi...

  • Page 30

    English rais - manual for rais 2:1 30 april 2014 spare parts diagram - rais 2:1 position / ref quantity item no description 1 2 9101401sort complete front 2 2 9101090 door - left hinged 2 9101090h door - right hinged 9101090l door - left hinged - locked 9101090lh door - right hinged - locked 9101032...

  • Page 31

    English rais - manual for rais 2:1 31 april 2014.

  • Page 32

    English rais - manual for rais 2:1 32 april 2014.

  • Page 33

    English rais - manual for rais 2:1 33 april 2014.

  • Page 34

    English rais - manual for rais 2:1 34 april 2014.

  • Page 35

    English rais - manual for rais 2:1 35 april 2014.

  • Page 36

    English rais - manual for rais 2:1 36 april 2014 u k distributor. Robeys ltd. Riverside, goods road, belper, derbyshire, england. De56 1uu tel: 01773 820940 fax: 01773 820477 e mail: info@robeys.Co.Uk www.Robeys.Co.Uk april 2014.