- DL manuals
- RAIS
- Wood stove
- JUNO
- Instructions For Installation, Use And Maintenance Manual
RAIS JUNO Instructions For Installation, Use And Maintenance Manual
ENGLISH RAIS - manual for Rais Rina, Rais Viva & Rais Juno
1
INSTRUCTIONS FOR INSTALLATION,
USE AND MAINTENANCE
RAIS RINA, RAIS VIVA & RAIS JUNO
IMPORTANT INFORMATION
On first lighting the stove you must be careful not to touch the painted
surfaces and it is MOST IMPORTANT that the door is kept slightly ‘ajar’ in
order for the door seal and sealant to cure.
This will prevent the door seal sticking to the painted body and becoming
damaged.
Summary of JUNO
Page 1
English rais - manual for rais rina, rais viva & rais juno 1 instructions for installation, use and maintenance rais rina, rais viva & rais juno important information on first lighting the stove you must be careful not to touch the painted surfaces and it is most important that the door is kept slig...
Page 2
English rais - manual for rais rina, rais viva & rais juno 2 date : 2012 sept manufacturers plate……………………………………………….. 3 - 4 introduction ………………………………………………………….. 5 warranty …………………………………………………….………….. 5 specifications ………………………………………………………….. 6 hetas ………………………………………………………………………. 7 - 14 installation ...
Page 3
English rais - manual for rais rina, rais viva & rais juno 3.
Page 4
English rais - manual for rais rina, rais viva & rais juno 4.
Page 5
English rais - manual for rais rina, rais viva & rais juno 5 a rais wood burning stove is more than just a heat source: it also shows that you care about design and quality in your home. To make the most of your wood burning stove it is important that you read the manual thoroughly before installing...
Page 6
English rais - manual for rais rina, rais viva & rais juno 6 r in a 9 0 n o m in a l o u tp u t (k w ): 4 .6 h e a ti n g a re a ( m 2 ): c a . 3 0 -9 0 s iz e , w id th /d e p th /h e ig h t (m m ): 4 6 1 / 4 1 0 / 9 0 0 c o m b u s ti o n c h a m b e r w id th /d e p th /h e ig h t (m m ). 2 9 5 /...
Page 7
English rais - manual for rais rina, rais viva & rais juno 7 please note that it is a legal requirement under england and wales building regulations that the installation of the stove is either carried out under local authority building control approval or is installed by a competent person register...
Page 8
English rais - manual for rais rina, rais viva & rais juno 8 stove performance in the uk the stove has been approved by hetas ltd as an intermittent operating appliance for burning wood logs only. It should be noted that it is an offence to burn wood logs in this stove if it is installed within a sm...
Page 9
English rais - manual for rais rina, rais viva & rais juno 9 a single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney. The chimney and connecting fluepipe must have a minimum diameter of 150 mm and its dimension should be...
Page 10
English rais - manual for rais rina, rais viva & rais juno 10 combustion air supply in order for the stove to perform efficiently and safely there should be an adequate air supply into the room in which the stove is installed to provide combustion air. This is particularly necessary if the room is d...
Page 11
English rais - manual for rais rina, rais viva & rais juno 11 installation it is prohibited to carry out unauthorised alterations to the stove. There must be plenty of fresh air in the room where the stove is being installed, in order to ensure proper combustion. Note that any mechanical exhaust ven...
Page 12
English rais - manual for rais rina, rais viva & rais juno 12 warning note properly installed, operated and maintained this stove will not emit fumes into the dwelling. Occasional fumes from de‑ashing and re‑fuelling may occur. However, persistent fume emission is potentially dangerous and must not ...
Page 13
English rais - manual for rais rina, rais viva & rais juno 13 if the stove is fitted in place of an open fire then the chimney will require sweeping after a month of continuous operation. This is a precaution to ensure that any “softer” deposits left from the open fire usage have not been loosened b...
Page 14
English rais - manual for rais rina, rais viva & rais juno 14 chimney fires if the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does occur turn off the stove immediately and isolate the mains electricity supply (if applicable), and tightly clo...
Page 15
English rais - manual for rais rina, rais viva & rais juno 15.
Page 16
English rais - manual for rais rina, rais viva & rais juno 16.
Page 17
English rais - manual for rais rina, rais viva & rais juno 17.
Page 18
English rais - manual for rais rina, rais viva & rais juno 18.
Page 19
English rais - manual for rais rina, rais viva & rais juno 19 normal set-up - corner setting rina a. Distance to furniture 700 mm distance to flammable materials: b. - in front (floor) 300 mm c. - to the side (floor) 150 mm d. - to the rear (floor) 150 mm e. - to the side of the wall 350 mm.
Page 20
English rais - manual for rais rina, rais viva & rais juno 20 normal set-up - corner setting viva viva g a. Distance to furniture 700 mm 650 mm distance to flammable materials: b. - in front (floor) 300 mm 300 mm c. - to the side (floor) 150 mm 150 mm d. - to the rear (floor) 100 mm 150 mm e. - to t...
Page 21
English rais - manual for rais rina, rais viva & rais juno 21 corner setting 45° fixed socket rina a. Distance to furniture 700 mm distance to flammable materials: b. - in front (floor) 300 mm c. - to the side (floor) 150 mm d. - to the rear (wall) 150 mm e. - to the side of the wall 350 mm.
Page 22
English rais - manual for rais rina, rais viva & rais juno 22 corner setting 45° fixed socket viva viva g distance to furniture 700 mm 650 mm distance to flammable materials: b. - in front (floor) 300 mm 300 mm c. - to the side (floor) 150 mm 150 mm d. - to the rear (wall) 100 mm 200 mm e. - to the ...
Page 23
English rais - manual for rais rina, rais viva & rais juno 23 360° swivel base viva viva g distance to furniture 700 mm 650 mm distance to flammable materials: c. - to the side (floor) 300 mm 300 mm.
Page 24
English rais - manual for rais rina, rais viva & rais juno 24 installation distance in case of non-combustible wall we recommend a minimum distance to non-combustible material of 50 mm (f) for clean-ing considerations. Using uninsulated flue pipe, the minimum distance to a combustible wall must be 4...
Page 25
English rais - manual for rais rina, rais viva & rais juno 25.
Page 26
English rais - manual for rais rina, rais viva & rais juno 26.
Page 27
English rais - manual for rais rina, rais viva & rais juno 27.
Page 28
English rais - manual for rais rina, rais viva & rais juno 28 refuelling keep the firebox well filled (the fuel may be sloped up from the front firebars), but do not allow fuel to spill over the top of the front fire bars. Take care that fuel does not project over the front fire bars or damage to th...
Page 29
English rais - manual for rais rina, rais viva & rais juno 29 only use recommended fuels the following table shows the calorific value of different types of wood, which have been stored for 2 years and which have a residual moisture of 15 - 17%. Wood kg dry wood pr m 3 compared to beech/oak hornbeam...
Page 30
English rais - manual for rais rina, rais viva & rais juno 30 drying and storage drying wood takes time: proper air drying takes approximately 2 years. Here are some tips: store the wood sawn, split and stacked in an airy, sunny place, which is protected against rain (the south side of the house is ...
Page 31
English rais - manual for rais rina, rais viva & rais juno 31 lighting and fuelling "top-down" lighting start by placing 3-4 pieces wood - approx. 1 ½ - 2 kilogram - in the bottom of the burning chamber. Place approx. 1 kilogram of dry firewood, split into kindling sticks., and a couple of alcohol b...
Page 32
English rais - manual for rais rina, rais viva & rais juno 32.
Page 33
English rais - manual for rais rina, rais viva & rais juno 33.
Page 34
English rais - manual for rais rina, rais viva & rais juno 34.
Page 35
English rais - manual for rais rina, rais viva & rais juno 35 cleaning of flue way the flue ways are consist of a smoke converter plate and a smoke chicane. Both parts are made of vermiculite. Handle these parts carefully. Remove dirt and dust, and mount the parts in reverse order. Remove the smoke ...
Page 36
English rais - manual for rais rina, rais viva & rais juno 36 problem solving smoke spillage around door: - could be due to too low draught in the chimney - check if the flue or chimney is blocked - check if a extraction hood is switched on; if it is, switch it off and open a window/door in the prox...
Page 37
English rais - manual for rais rina, rais viva & rais juno 37 accessories and spare parts if spare parts other than those recommended by rais are used, the warranty is voided. All replacement spare parts can be purchased from your rais distributor / stockist. See the following spare parts diagrams f...
Page 38
English rais - manual for rais rina, rais viva & rais juno 38 spare parts diagram - rina pos./ref. Quantity part no: description 1 1 1312090 glass door 2 1 3310404 cover for wood compartment 3 1 3310601 top plate without hole 4 1 3310602 top plate with hole 5 1 61-00 flue collar 6” 6 1 1313800 shaki...
Page 39
English rais - manual for rais rina, rais viva & rais juno 39 rina.
Page 40
English rais - manual for rais rina, rais viva & rais juno 40 spare parts diagram - viva 98 pos./ref. Quantity part no: description 1 1 1312090 glass door 2 1 2310601 top plate without hole 3 1 2310602 top plate with hole 4 1 61-00 flue collar 6” 5 1 1313800 shaking grate 6 1 1314001 ash pan 7 1 131...
Page 41
English rais - manual for rais rina, rais viva & rais juno 41 viva 98.
Page 42
English rais - manual for rais rina, rais viva & rais juno 42 spare parts diagram - viva 120 pos./ref. Quantity part no: description 1 1 1312090 glass door 2 1 2310601 top plate without hole 3 1 2310602 top plate with hole 4 1 61-00 flue collar 6” 5 1 1313800 shaking grate 6 1 1314001 ash pan 7 1 13...
Page 43
English rais - manual for rais rina, rais viva & rais juno 43 viva 120
Page 44
English rais - manual for rais rina, rais viva & rais juno 44 spare parts diagram - viva 98 g pos./ref. Quantity part no: description 1 1 1312090 glass door 5 1 2310601 top plate without hole 6 1 2310602 top plate with hole 7 1 61-00 flue collar 6” 8 1 1313800 shaking grate 9 1 1314001 ash pan 10 1 ...
Page 45
English rais - manual for rais rina, rais viva & rais juno 45 viva 98 g.
Page 46
English rais - manual for rais rina, rais viva & rais juno 46 spare parts diagram - viva 120 g pos./ref. Quantity part no: description 1 1 1312090 glass door 5 1 2310601 top plate without hole 6 1 2310602 top plate with hole 7 1 61-00 flue collar 6” 8 1 1313800 shaking grate 9 1 1314001 ash pan 10 1...
Page 47
English rais - manual for rais rina, rais viva & rais juno 47.
Page 48
English rais - manual for rais rina, rais viva & rais juno 48.
Page 49
English rais - manual for rais rina, rais viva & rais juno 49.
Page 50
English rais - manual for rais rina, rais viva & rais juno 50
Page 51
English rais - manual for rais rina, rais viva & rais juno 51.
Page 52
English rais - manual for rais rina, rais viva & rais juno 52.
Page 53
English rais - manual for rais rina, rais viva & rais juno 53.
Page 54
English rais - manual for rais rina, rais viva & rais juno 54.
Page 55
English rais - manual for rais rina, rais viva & rais juno 55.
Page 56
English rais - manual for rais rina, rais viva & rais juno 56 u k distributor. Robeys ltd. Riverside, goods road, belper, derbyshire, england. De56 1uu tel: 01773 820940 fax: 01773 820477 e mail: info@robeys.Co.Uk www.Robeys.Co.Uk october 2011.