English rais manual for rais qtee 1 instructions for installation, use and maintenance rais qtee important information on first lighting the stove you must be careful not to touch the painted surfaces and it is most important that the door is kept slightly ‘ajar’ in order for the door seal and s...
English rais manual for rais qtee 2.
English rais manual for rais qtee 3 revision : date : 2011 introduction ………………………………………………………….. 4 warranty …………………………………………………….………….. 4 specifications ………………………………………………………….. 5 convection ………………………………………………………………. 6 installation instructions ………………………………….……… 7 chimney …………………………………………………….………...
English rais manual for rais qtee 4 a rais wood burning stove is more than just a heat source: it also shows that you care about design and quality in your home. To make the most of your wood burning stove it is important that you read the manual thoroughly before installing and using it. In the ...
English rais manual for rais qtee 5 q t ee 57 no m in al o u tp u t ( kw) : 4.7 m in . / m ax . O u tp u t ( kw) : 4 5 heat in g a rea ( m 2 ): ca. 3 0 90 s ize, wi d th /d e p th /h ei g h t ( m m ): 42 5 / 3 7 2 / 5 70 co m b u st io n c h ambe r wi d th /d ep th /h eig h t (m m ). 31 7 / 2...
English rais manual for rais qtee 6 convection rais stoves are convection stoves. This means that the stove’s back and side panels are not overheated. Convection means that there is a circulation of air, which ensures that the heat is distributed more evenly throughout the entire room. The cold ...
English rais manual for rais qtee 7 please note that it is a legal requirement under england and wales building regulations that the installation of the stove is either carried out under local authority building control approval or is installed by a competent person registered with a government a...
English rais manual for rais qtee 8 stove performance in the uk the stove has been approved by hetas ltd as an intermittent operating appliance for burning wood logs only. Preparatory work and safety checks important warning this stove must not be installed into a chimney that serves any other he...
English rais manual for rais qtee 9 a single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney. The chimney and connecting fluepipe must have a minimum diameter of 125 mm and its dimension should be not less than the siz...
English rais manual for rais qtee 10 combustion air supply in order for the stove to perform efficiently and safely there should be an adequate air supply into the room in which the stove is installed to provide combustion air. This is particularly necessary if the room is doubleglazed or a flue...
English rais manual for rais qtee 11 installation it is prohibited to carry out unauthorised alterations to the stove. There must be plenty of fresh air in the room where the stove is being installed, in order to ensure proper combustion. Note that any mechanical exhaust ventilation e.G. An ext...
English rais manual for rais qtee 12.
English rais manual for rais qtee 13 remove the casing knockout. Remove the protective cover / seal and place over the hole in the top make sure that the seal is positioned properly. Tighten the assembly using the three m6 nuts. The flue outlet spigot, which can be found in the stove in a bag,...
English rais manual for rais qtee 14 installation distance to combustible wall to find out whether the wall next to where the stove is going to be installed is flammable, you should contact your building contractor or the local building authorities. The hearth should be able to accommodate the we...
English rais manual for rais qtee 15 normal setup corner setting uninsulated flue insulated flue a. Distance to furniture 650 mm 650 mm distance to flammable materials: b. in front (floor) 300 mm 300 mm c. to the side (floor) 150 mm 150 mm d. to the rear (floor) 350 mm 275 mm e. to th...
English rais manual for rais qtee 16 corner setting 45° fixed socket un insulated flue insulated flue a. Distance to furniture 650 mm 650 mm distance to flammable materials: b. in front (floor) 300 mm 300 mm c. to the side (floor) 150 mm 150 mm d. to the rear (wall) 225 mm 175 mm e. to th...
English rais manual for rais qtee 17 installation distance in case of noncombustible wall we recommend a minimum distance to noncombustible material of 50 mm (f) for cleaning considerations. Using uninsulated flue pipe, the minimum distance to a combustible wall must be 450mm or 225mm if the w...
English rais manual for rais qtee 18 warning note properly installed, operated and maintained this stove will not emit fumes into the dwelling. Occasional fumes from de‑ashing and re‑fuelling may occur. However, persistent fume emission is potentially dangerous and must not be tolerated. In the e...
English rais manual for rais qtee 19 if the stove is fitted in place of an open fire then the chimney will require sweeping after a month of continuous operation. This is a precaution to ensure that any “softer” deposits left from the open fire usage have not been loosened by the higher flue temp...
English rais manual for rais qtee 20 chimney fires if the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does occur turn off the stove immediately and isolate the mains electricity supply (if applicable), and tightly close the doors of the st...
English rais manual for rais qtee 21 refuelling keep the firebox well filled (the fuel may be sloped up from the front firebars), but do not allow fuel to spill over the top of the front fire bars. Take care that fuel does not project over the front fire bars or damage to the glass may be caused ...
English rais manual for rais qtee 22 only use recommended fuels the following table shows the calorific value of different types of wood, which have been stored for 2 years and which have a residual moisture of 15 17%. Wood kg dry wood pr m 3 compared to beech/oak hornbeam 640 110% beech and oa...
English rais manual for rais qtee 23 drying and storage drying wood takes time: proper air drying takes approximately 2 years. Here are some tips: store the wood sawn, split and stacked in an airy, sunny place, which is protected against rain (the south side of the house is particularly suitable)...
English rais manual for rais qtee 24 control if the ash is white and the walls in the combustion chamber are soot free after the stove has been used, the air regulation was set correctly and the wood was sufficiently dry. Using the wood burning stove adjusting the air damper. The damper has 3 set...
English rais manual for rais qtee 25 first usage a careful start pays off. Start with a small fire, so that the wood burning stove can get accustomed to the high temperature. This gives the best start and any damage is avoided. Be aware that a strange but harmless odour and smoke concoction may e...
English rais manual for rais qtee 26 lighting and fuelling "topdown" lighting start by placing 34 pieces wood approx. 1 ½ 2 kilogram in the bottom of the burning chamber. Place approx. 1 kilogram of dry firewood, split into kindling sticks., and a couple of alcohol briquettes or similar (...
English rais manual for rais qtee 27.
English rais manual for rais qtee 28 cleaning and care the wood burning stove and the chimney must be serviced by a chimney sweep twice a year. During cleaning and care, the stove must be cold. If the glass is sooty: moisten a piece of paper or newspaper, dip it in the ash, and rub the sooty gl...
English rais manual for rais qtee 29 remove the smoke converter plate by tilting it to one side and turning it a little slantwise. Pull out the plate carefully. Then remove the smoke baffle by pushing it backwards, tipping it up on one side and turn slightly tilted. Carefully lift out the smoke b...
English rais manual for rais qtee 30 problem solving smoke spillage around door: could be due to too low draught in the chimney check if the flue or chimney is blocked check if a extraction hood is switched on; if it is, switch it off and open a window/door in the proximity of the stove for...
English rais manual for rais qtee 31 accessories and spare parts if spare parts other than those recommended by rais are used, the warranty is voided. All replacement spare parts can be purchased from your rais distributor / stockist. See the following spare parts diagrams for the individual prod...
English rais manual for rais qtee 32 spare parts diagram rais qtee pos./ref. Quantity part no.: description 1 1 835010390 mantle qtee 65 2 1 835010290 mantle qtee 57 3 1 8352090 steel door 4 1 8351090 glass door 5 1 835052490 cover qtee 57 6 1 835050490 cover qtee 65 7 1 8352200 fire brick...
English rais manual for rais qtee 33.
English rais manual for rais qtee 34.
English rais manual for rais qtee 35.
English rais manual for rais qtee 36.
English rais manual for rais qtee 37.
English rais manual for rais qtee 38.
English rais manual for rais qtee 39.
English rais manual for rais qtee 40
English rais manual for rais qtee 41.
English rais manual for rais qtee 42 u k distributor. Robeys ltd. Riverside, goods road, belper, derbyshire, england. De56 1uu tel: 01773 820940 fax: 01773 820477 e mail: info@robeys.Co.Uk www.Robeys.Co.Uk june 2011.