1 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com table of contents do not install this gate operator system unless you are a trained, experienced gate technician warning 1. Read, understand & follow the instruction manual. 2. Never let children operate or play with gate controls. Keep the remote con...
2 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 responsibilities of installers and technicians installation • read and understand the instruction manual before attempting any installation. • use the proper operator. Take the following into consideration: സ category (swing, slide or overhead) ̶ type...
3 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com responsibilities of installers and technicians cont. • warning signs must be permanently affixed to the gate panel in a highly visible place that can be easily seen from both sides of the gate. • a separate entrance is supplied for pedestrians. The op...
4 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 prior to installation, the following must be observed: (ul 325.58.8.4) a) install the gate operator only when: 1. The operator is appropriate for the construction of the gate and the usage class of the gate, 2. All openings of a horizontal slide gate ...
5 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com model hp voltage run start r100/r1000 1/2 115vac 4.5 5.0 r5500-3/4 3/4 115vac 8.5 9.0 r5500-1 1 115vac 9.4 9.9 12ga 10ga 8ga 6ga up to 225' 226-370' 371-550' 551-925' up to 115' 116-195' 196-290' 291-495' n/a up to 175' 176-265' 266-445' class i resid...
6 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 model ram 100 ram 1000 ram 5500 3/4 hp ram 5500 1hp max. Gate travel 20 feet 45 feet 45 feet 45 feet max. Gate weight 700 lbs 1000 lbs 1500 lbs 2500 lbs cycles continuous continuous continuous continuous capacitor aerovox 65µƒ, 240 v, 50/60 hz, protec...
7 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com 24” 4” min 4” 6 1/2” 5 3/4” 5” 3” min gate wall conduit for master-slave conduit for power conduit for low voltage wires 18” x 18” x 24” concrete pad (minimum) top view gate shown open lh front installation wall gate 4” 4” min gate 6” 7 1/4” 11 3/4” b...
8 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 foot pedal release ram 100 front installation front installation gate shown closed tail on gate required tail wall 5 3/4” 4” min 10” figure 4 after proper use of the foot pedal, be sure to lightly kick the pedal towards the right side to spring the pe...
9 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com gate 6” 8 5/8” 13 3/4” base operator concrete 18” (mimimum) concrete 18” (mimimum) 24” tail 4 1/2” 2 1/2” min 4” top view gate shown closed lh front installation cl mark centers and install four 1/2-13 unc red-head anchor bolts wall top view gate show...
10 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 ram 1000/ ram 5500 types of installations rear installation gate shown fully open no tail on gate required center installation gate shown fully open no tail on gate required front installation gate shown closed tail on gate required top view front vi...
11 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com 5 outside photo eye inside photo eye back-plane photo eye figure 12 loop sensor installation reversing loops on the ground floor, prevents gate from closing when vehicle is in loop area. Exit loops on the ground floor, opens gate when vehicle crosses...
12 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 in order to prevent serious injury, bodily harm or death from a moving gate: - entrapment protection devices must be installed to cover any and all entrapment danger areas and locations during a gates opening and closing cycles. Since every installat...
13 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com entrapment and safety protection general entrapment protection provisions a vehicular gate operator shall have provisions for, or be supplied with, at least two independent entrap- ment protection means as specified in table 1. At installation, both ...
14 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 led # function status results troubleshoot 1 power on 18-24v ac/dc present check 115vac, check 3a fuse, check transformer off no input power 3-4 motor 1 & 2 on motor is running check 15a sb fuse, check 115v ac, check motor over- load button (red) off...
15 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com primary/secondary installation (rh) right hand operation requires dip switch (a4) "left/right" to be on. Dip switch “a” use 3-stranded, shielded wires (not supplied) from primary to secondary. Route low-voltage wires for primary/secondary in a condui...
16 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 dip switch “a” dip switch “b” dip switch “c” “intelligate” control board figure 17 dip switch configuration dip switch s4 - “a” dip switch “a” 4 - left/right off left-hand installation on right-hand installation. Reverses the motor and limit wires wi...
17 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com dip switch configuration c1 - full rev erd off normal operation on when closing, if the gate senses an obstruction (erd), the gate will stop and reverse all the way to the fully open limit. C2 - slow off normal operation on adds a slow start when the...
18 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 limit switches radio receiver 115vac figure 18 safety eye safety loop det. Safety edge sensor fire box exit loop phone entry keypad open only phantom loop radio receiver keypad open & close edge sensor limit switch 2 slow stop switch 115 or 230 vac 1...
19 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com terminal # 1 - common low voltage common. Terminal 2 - safety stops the gate from closing. - gate open - holds gate open. - gate closed - gate stays closed. - gate opening - gate continues to open. - gate closing - gate stops, then opens. The functio...
20 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 plug connections relay connections lights, alarms & sirens loop inputs loop wires - only used with the plug-in rld-24 detectors plug in detectors used with the rld-24 detectors only input power 18vac from the transformer 3-button common, close, stop ...
21 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com jp2 - relay connections: 1) 24 vdc. 5) relay common 2) 24 vac 6) fully closed-n.C. 3) do not use 7-8) constant warn/prewarn - n.O. 4) fully open - n.O. 9-10) erd alarm (factory wired) all relays are rated at 125vac, 1a. Used with: lights or sirens th...
22 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 parts diagram ram 100 3 16 1 13 14 28 10 36 8 11 23 24 19 15 27 31 5 32 25 21 34 40 38.
23 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com ram 1000 • ram 5500 2 28 17 18 25 31 13 14 12 15 9 20 27 26 24 23 35 30 22 21 29 4 39 33 5,6,7 parts diagram 41 37.
24 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 item part # part description ram 100 ram 1000 ram 5500-3/4 ram 5500-1 1 800-00-00 chassis - r100 1 2 800-00-01 chassis - r1000/r5500s 1 1 1 3 800-02-03 gear reducer - size 43, ratio 30:1 (c-face) 1 4 800-02-06 gear reducer - size 60, ratio 30:1 (c-fa...
25 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com bill of materials item part # part description ram 100 ram 1000 ram 5500-3/4 ram 5500-1 35 800-75-31 idler wheel assembly - r1000/r5500s 2 2 2 800-36-52 bolt, hex head - 5/8" - 11 x 3 1/2" 1 1 1 800-38-18 nut, hex head - 5/8" 2 2 2 800-40-45 washer, ...
26 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 gate entrance safety precautions 1. Read and follow all instructions 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from the gate. No one should cross the p...
27 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com important information for the homeowner • ask your technician about all the features of your new ramset gate operator. • this operator should not be installed without at least one photo eye present. • other safety devices, such as reverse loops, phan...
28 ramset www.Ramsetinc.Com troubleshooting table condition possible causes solution no lights are ‘on’. 1. Circuit breaker popped. 2. 1/2 amp. Fuse blown. 3. Power supply damaged on control board. 1. Reset circuit breaker. 2. Replace 1/2 amp. Fuse. 3. Return control board for repair. Gate moves a c...