RAMSET TrakFast TF1100 Operating Instructions Manual - Troubleshooting
TROUBLESHOOTING
TROUBLESHOOTING
15
SYMPTOM
POSSIBLE PROBLEMS
SERVICE
Pre-Combustion/Combustion Stage of Operation
Power/Exhaust Stage of Operation
— Work Contacting
Element does not
depress fully—tool
does not operate .
— Tool will not cycle-fan
runs, LED is green .
— Tool operates properly,
but fasteners do not
drive fully .
— Tool operates, but no
fastener is driven .
— Tool operates erratically
or appears to be
losing power—tool
LED is green .
— Lockout Bracket is stuck
in lockout position .
— Work Contacting
Element is bent, or
build-up of debris in
track restricts operation .
— Follower is not behind
strip .
— Fan motor O-Ring
pinched .
— Fuel Cell is empty .
— Spark Wire out of spark
plug .
— Spark does not occur .
— Battery cell is
discharged .
— Fuel Cell is low .
— There may be loss of
seal in combustion
chamber .
— Fastener strip may be
binding .
— Follower not properly
engaged behind fastener .
— Jammed fastener .
— Fuel Cell is low .
— Spark Plug wire is
loose .
— Filter element is dirty,
causing tool to overheat .
— Tool Sleeve or O-Rings
are dirty .
— Check Negator Cover screw for excessive
tightness . Remove cover if necessary and
clean out build-up of debris from track .
— Remove and inspect Lower Probe . Clean
track with cloth . Repair or replace Lower
Probe as required .
— Put follower behind strip .
— Contact Authorized Ramset Distributor
Sales Representative for service .
— Replace Fuel Cell .
— Contact Authorized Ramset Distributor
Sales Representative for service .
— Contact Authorized Ramset Distributor
Sales Representative for service .
— Charge Battery Cell .
— Check Fuel Cell according to Operating
Manual and replace as required .
— Press Work Contact Element against work-
piece for one minute . Pull trigger . If fastener
does not drive, there is a leak that requires
service .
— Use only fasteners meeting Ramset
specifications .
— Locate follower behind fastener strip and
engage strip according to instructions in
Operating Manual .
— Clear jam according to Operating Manual .
— Check Fuel Cell according to Operating
Manual .
— Contact Ramset Distributor Sales
Representative for Service .
— Remove Filter element and clean according
to Operating Manual . Use safe cleaning
solution to remove stubborn debris .
— Clean tool per Cleaning Procedure .