SELECTING A LOCATION FOR YOUR NEW UNIT
The following conditions should be considered when selecting a location for your
unit:
1.
Floor and Countertop Load: The area on which the unit will rest
must be level, free of vibration, and suitably strong enough to support
the combined weights of the unit plus the maximum product load
weight.
NOTE: If there is a question pertaining to weight load limits, consult the
factory at 1-800-621-8560.
2. Clearance: There must be a combined total of at least 3” clearance on
all sides of the unit. The top of the unit must be completely clear of any
other objects or materials.
3. Ventilation: The air cooled self contained unit requires a sufficient
amount of cool clean air. Avoid surrounding your display case around
other heat generating equipment and out of direct sunlight. Also, avoid
locating in an unheated room or where the room temperature may drop
below 55° F (13°C) or rise above 86° F (32°C).
INSTALLATION CHECKLIST
After the final location has been determined, refer to the following checklist prior to
start-up:
1. Check all exposed refrigeration lines to ensure that they are not kinked,
dented, or rubbing together.
2. Check that the condenser and evaporator fans rotate freely without
striking any stationary members.
3. Unit should be properly leveled.
4. Plug in unit and turn on main on/off power switch.
5. Turn switch on for florescent lights.
6. Allow unit time to cool down to temperature. If temperature
adjustments are required, the temperature control can be accessed by
removing the louver on the left side of the display cooler. (See page 12,
Unit Operation, for more information on temperature adjustments).
7. Refer to the front of this manual for serial number location. Please
record this information in your manual on page 3 now. It will be
necessary when ordering replacement parts or requesting warranty
service.
8. Confirm that the unit is holding temperature. Set controls to desired
temperature for your particular ambient and altitude.
9. Allow your unit to operate for approximately 2 hours before putting in
food to allow interior of unit to cool down to storage temperature.
NOTE: All motors are oiled and sealed.
NOTE: FAILURE TO FOLLOW INSTALLATION GUIDELINES AND
RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT.