    8/26/2008 pp mnl0023 rev b (8.2008) operator’s manual this manual provides information on installation, operating, maintenance, trouble shooting & replacement parts for countertop display case 40048a 40048ssa notify carier of damage at once. It is the responsibility of the consignee to inspect the c...

  • Page 3: Table Of Contents

    Unifiedbrands.Net 3 table of contents page 3……………………..Congratulations / table of contents page 4……………………………………parts & service hotline page 4………………………………...…serial number location page 5-8……………………………….Randell limited warranty page 9…………………………………………unit specifications page 10-11....……………………………..……...U...

  • Page 4: 800-621-8560

    4 4 4 4 800-621-8560 in addition, all randell food service equipment is backed by some of the best warranties in the food service industry and by our professional staff of service technicians. Retain this manual for future reference. Notice: due to a continuous program of product improvement, randel...

  • Page 5: Warranty Policies

    Unifiedbrands.Net 5 warranty policies randell believes strongly in the products it builds and backs them with the best warranty in the industry. Standard with every unit is the peace of mind that this unit has been thoroughly engineered, properly tested and manufactured to excruciating tolerances, b...

  • Page 6

    6 6 6 6 800-621-8560 temperature adjustments are not covered under warranty, due to the wide range of ambient conditions. To inquire if the equipment is within warranty, call our field service department at: 800-621-8560. When optional 5 year compressor warranty applies 1. Provide reimbursement to a...

  • Page 7

    Unifiedbrands.Net 7 notice: food loss is not covered under warranty 3. Repairs caused by abuse such as broken glass, freight damage, or scratches and dents. 4. Electrical component failure due to water damage from cleaning procedures. Quotations verbal quotations are provided for customer convenienc...

  • Page 8

    8 8 8 8 800-621-8560 damages all crating conforms to general motor carrier specifications. To avoid concealed damage, we recommend inspection of every carton upon receipt. In the event the item shows rough handling or visible damage to minimize liability, a full inspection is necessary upon arrival....

  • Page 9: Unit Specifications

    Unifiedbrands.Net 9 unit specifications 40048a shown model l d h style storage cu. Ft. Sq. Ft. H.P. Volts amps nema ship wt. 40048a 48" 26.5" 25" dbl. Serve 7 14 1/3 115 8.1 5-15p 370 40048ssa 48" 26.5" 25" single serve 7 14 1/3 115 8.1 5-15p 370

  • Page 10: Unit Installation

    10 10 10 10 800-621-8560 unit installation selecting a location for your new unit the following conditions should be considered when selecting a location for your unit: 1. Floor and countertop load: the area on which the unit will rest must be level, free of vibration, and suitably strong enough to ...

  • Page 11

    Unifiedbrands.Net 11 electrical supply: the wiring should be done by a qualified electrician in accordance with local electrical codes. A properly wired and grounded outlet will assure proper operation. Please consult the data tag attached to the compressor to ascertain the correct electrical requir...

  • Page 12: Unit Operation

    12 12 12 12 800-621-8560 unit operation randell has preset the cold control to ensure that your unit runs at an optimum temperature, but due to varying ambient conditions, including elevation, food product as well as type of operation, you may need to alter this temperature. It is strongly recommend...

  • Page 13: Preventive Maintenance

    Unifiedbrands.Net 13 preventive maintenance randell strongly suggests a preventive maintenance program which would include the following monthly procedures: 1. Cleaning of all condenser coils. Condenser coils are a critical component in the life of the compressor and must remain clean to assure prop...

  • Page 14

    14 14 14 14 800-621-8560 preventive maintenance (cont.) door installation: 1. Locate inside door (sticker to identify door in lower corner of door) 2. Place black spring closure tab at rear top of door. 3. Pick up on door 4. Insert lower part of door in to track when door is 3” open 5. Assure door s...

  • Page 15

    Unifiedbrands.Net 15 preventive maintenance (cont.) recommended cleaners for your stainless steel include the following: job cleaning agent comments routine cleaning soap, ammonia, detergent medallion apply with a sponge or cloth fingerprints and smears arcal 20, lac-o-nu, ecoshine provides a barrie...

  • Page 16: Trouble Shooting Guide

    16 16 16 16 800-621-8560 trouble shooting guide symptom possible cause procedure unit doesn't run 1. No power to unit 1. Plug in unit 2. Temperature control turned off 2. Check temperature control 3. Temperature control faulty 3. Test temperature control 4. Compressor overheated 4. Clean condenser c...

  • Page 17: Electrical Diagram

    Unifiedbrands.Net 17 electrical diagram.

  • Page 18: Exploded View

    18 18 18 18 800-621-8560 exploded view 40048a/40048ssa countertop display case.

  • Page 19: Exploded View

    Unifiedbrands.Net 19 exploded view 40048a/40048ssa countertop display case.

  • Page 20: Replacement

    20 20 20 20 800-621-8560 replacement parts 40048a/40048ssa countertop display case item # description part # 40048a 40048ssa 1 glass retainer frame, solid glass panel only hd trk3563 x 2 glass panel, solid hd gls134 x 3 s/s top, after 11/2005 rp top4048 x x 4 evaporator fan guard rf fan010 x x 5 eva...

  • Page 21

    Unifiedbrands.Net 21 item # description part # 40048a 40048ssa 36 compressor, 1/3hp, aea4440yxa rf cmp020-134p x x 37 cond. Fan motor w/ blade & guard, after 11/2005 rf asy0101p x x 38 condensing unit, 1/3hp, aea4440yxa, after 11/2005 rf con0110 x x 39 power switch, light el swt0502 x x 40 accumulat...