WARNING! CHECK FOR PROPER VENTING
A properly sized, unobstructed chimney will normally vent all products of combustion. Any odor or smoke detected
inside the room is an indication that the flue is not functioning properly.
SHUT OFF THE BURNER IMMEDIATELY! THE CAUSE OF THE VENTING PROBLEM MUST BE DISCOVERED AND
CORRECTED BEFORE CONTINUED USE OF THE GAS LOG SET.
Continued use with improper venting may cause damage to your fireplace, room furnishings and could cause serious illness.
IF IMPROPER VENTING IS SUSPECTED, IMMEDIATELY HAVE BURNER AND CHIMNEY FLUE SERVICED
.
ALSO, VERIFY THAT LOG SET IS INSTALLED PER THESE INSTRUCTIONS.
C) Burner Pan
B) Approx. 0” to 2”
D)
V1 Gas Valve
Gas
Supply Pipe
Front Width
(Minimum 6” greater than log set size)
Depth
Minimum 13”
Rear Width
(Not less than log set size)
Long Valve
Key (K2)
(sold separately)
1. Place Grate inside the firebox, centered from left to right, 0” to 2” of rear wall, as depth permits (Figure 3B).
2. Place Burner Pan beneath grate with open edge facing out approximately one inch forward of front legs of grate.
(Figure 2 and 3C) Mark positions of Grate and Burner Pan on fireplace floor with pencil then remove from the firebox
(Figure 3D).
STEP TWO: POSITIONING BURNER PAN AND GRATE
FIGURE 3
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically
approved with this heater may result in property damage or personal injury.
LEAK TEST PROCEDURES
WARNING: DO NOT use an open flame to test leaks!
Create a mixture of equal parts soap and water. Apply to all the joints of the pipe fittings from the gas supply to the
burner. Turn on the gas supply valve for no longer than 3-5 seconds. If bubbles appear in the soap solution applied
to the joints, there is a leak. Turn off the gas supply valve and tighten those fittings. Repeat the procedure until
bubbles no longer appear. Remember to test all joints.
NOTE: Always perform a leak test any time the appliance has been moved or disconnected from the gas supply line.