Rasmussen RMC1E General Assembly, Installation, And Operation Instructions - page 4
4
The “EASY” Safety Valve (Figure 7B) and Remote Receiver (Figure 7C) are both adversely affected by heat and must
be placed as far forward and to the side of the burner pan as possible (bottom right). The “EASY” Safety Valve
may also be placed open face side down with heat shield up as shown in Figure 7D. Our optional Ceramic Log House
accessory (Figure 7E), offers heat protection for the Remote Receiver while being pleasing to the eye. When connecting
receiver to “EASY” Safety Valve be sure to match red and black connectors (Figure 7F, red to red and black to black).
WARNING
•
DO NOT remove Heat Shield (Figure 7A) . It is intended to prevent premature valve failure and voiding of
warranty. Replace immediately if removed for any reason.
•
The “EASY” Safety Control Valve must be protected to a maximum ambient temperature of 225° F.
Excessive heat to the valve is indicated by melted plastic or wiring on the valve body and is not warrantable.
•
Allow an adequate period of cooling after use before closing glass doors.
•
NEVER operate your gas log set with glass doors closed.
•
DC POWER FROM THE RECEIVER OPERATES THIS UNIT. DO NOT CONNECT TO A 115V AC LINE. SAFETY
CONTROLS DAMAGED BY HEAT OR AC ARE NOT COVERED BY WARRANTY.
SUGGESTED FIREBOX LAYOUT AND REQUIRED PARTS
FIGURE 7
Internally Tapped 3/8 Flared x 3/8 MIP Elbow
Burner Plug
Burner Pipe
Air Mixer For LP Gas
Burner Inlet Assembly
10” Flex Connector
Burner Pan
Pilot Thermocouple Assembly
Burners
B) “EASY” Safety Valve
Heat Shield
A)
E.
F.
D.
C) Remote
Receiver