Ravelli o-ring User Manual

Summary of o-ring

  • Page 1

    En user manual o-ring.

  • Page 3

    Introduction safety information general information what are wood pellets how is a stove made combustion stove installation advice for installation approved installations system compatibility check air vent fume duct and fittings flue flue dataplate chimney cap (uni 7129/08) testing and commissionin...

  • Page 4

    Alarms (reference table) maintenance cleaning should be provided by the user clean the surfaces grate cleaning should be carried out before each switch-on cleaning the ash pan cleaning glass warranty warranty certificate warranty conditions info and problems wiring diagram 27 28 28 28 28 29 29 30 30...

  • Page 5

    Introduction warning we recommend you carefully read this booklet, which describes all the necessary phases for perfect functioning of your stove. Note: the standards relevant to the installation and functioning contained in this manual can differ based on local standards in force. In this case, alw...

  • Page 6

    Safety information the stove must be installed and inspected by specialist staff trained by head office. Please carefully read this user and maintenance manual before installing and operating the stove. If you require further clarification, contact your nearest ravelli srl dealer. The stove must be ...

  • Page 7

    Spare parts exclusively use original spare parts. Do not wait for the components to deterio- rate before replacing them. Replace a worn component before it is completely broken to prevent any ac- cidents due to sudden breakage of the components. Carry out periodic mainte- nance controls as described...

  • Page 8

    How is a stove made? Combustion combustion is nothing more than a chemical reaction in which two agents, called the fuel and the oxidizing agent, combine to produce a new substance. A considerable amount of heat is also produced from this reaction (concept of pellet stove functioning). To facilitate...

  • Page 9

    (from 0 to +5); if not sufficient, also reduce the per- centage of falling pellets (from 0 to -5) to arrive to the condition in figure 3. If the changes made to the settings do not bring the stove to the right combustion conditions in figure 3, contact the technical support centre. Correct combustio...

  • Page 10

    Rooms (only watertight installation) or studios (unless installed in a hermetically sealed combustion chamber). Excerpt of standard uni/en 1443 system compatibility check compatibility check of the system should be carried out before any installation or commissioning intervention. The adjacent, side...

  • Page 12

    Safe distances for proper installation of chimney terminal: symbol description clearance area [mm] c distance measured at 90° from roof surface 1300 a height above roof ridge 500 la release quota deve trovarsi al di fuori della zona di reflusso calcolata secondo il diagramma e la tabella sopra ripor...

  • Page 13

    Symbol description distanze da rispettare [mm] a 2 height above the virtual stratum between the build- ing roof or obstacles or adjacent thermal compart- ments in the absence of openings/windows 500 b *) height above flat roofs or close parapets 1000 *) if the terrace or flat roof is walkable, the c...

  • Page 14

    Declaration of conformity of the state-of-the-art system as per para.I of art. 7 of ministerial decree 37 of january 22, 2008 no. 20 the undersigned owner or legal representative of the company operating in the handcraft sector with premises in municipality prov. ( ) phone vat no £ registered in the...

  • Page 15

    £ installed parts and materials suitable for the place of installation (art.5 and 6) £ inspected the system for safety purposes and the functionality with positive out- come, having carried out the checks required by the standards and the provisions of the law. Mandatory annexes: £ designed accordin...

  • Page 16

    Reference key of system declaration of conformity 1. Like in the case of gas plants, by “other” we may mean the replacement of a device installed in a fixed manner. 2. Indicate: name, surname, qualification and (when there is an obligation as per art.5, paragraph 2) registration data to the relative...

  • Page 17: No!

    Examples of installation of a pellet stove this type of installation (see fig.1 ) requires the chimney to be insulated despite the fact that the entire duct is installed inside the building. Moreover, the struc- ture should be inserted into a properly ventilated skylight well. At the bottom of the c...

  • Page 18

    This type of installation (see fig. 4 ) requires insulated chimney since the entire smoke duct was assembled inside the house. The lower part of the flue has an assembled “t” joint with an inspection plug. It is not recommended to install a 90° curve as the first initial piece, since the ash could q...

  • Page 19

    This type of installation (see fig. 6 ) requires a horizontal section for connection to an existing flue. Comply with the slope indicated in the figure, to reduce de- positing ash in the horizontal tube section. In the lower part of the flue duct was installed a t fitting with inspection plug like f...

  • Page 20

    Here you can see the possibility to slide the insert; this operation can only be per- formed with the stove turned off for loading pellets or during regular checks. ( fig. 8 ) ! It is strictly forbidden to remove the stove during the work phases; the fume may disperse into the environment. Technical...

  • Page 21

    Preliminary operations wiring connect the power cord to the back of the stove and then to a wall socket. The i/o switch in the figure should be set to i to power the stove. If voltage is not supplied check the state of the fuse installed in the box below the switch (4a fuse). During the periods of i...

  • Page 22

    How to use the o-ring off state once you have checked that the i/o switch on the back of the stove is set to off and you have connected the power cord to the stove and the socket equipped with a protective earthing system, bring the switch to i. The o-ring will display a blue blinking light through ...

  • Page 23

    Pressed down until a turned off led starts rotating counter-clockwise: release the key. The stove will perform a final cleaning and the animation will remain active until complete cooling of the stove, after which it will go in off state, displaying the relative animation first infeed screw loading ...

  • Page 24

    For safe operation. Below are some examples of graphics displayed by the o- ring when fan speed is increased or decreased. -10 volt +10 volt -20 volt +20 volt -30 volt +30 volt ! Use this function carefully if the stove is running at maxi- mum power p12: do not slow down the fan too much to pre- ven...

  • Page 25

    Warning sign - hot fume one of the safety devices that controls your ravelli young stove, also checks that exhaust fume temperature does not exceed a certain threshold, which creates a hazard. There are, however, cases in which, even during normal operation, the fume temperature may rise slowly due ...

  • Page 26

    Alarm 3 - fume overheating (hot fume) this is not the same signal as the warning hot fume signal. It is triggered when fume temperature rises above the set threshold, that cannot be changed for safe- ty reasons. The o-ring will display the following error through the red leds. Alarm 4 - fume encoder...

  • Page 27

    In the case of alarm 07 thermal breaker below shows the location where to operate to reset the thermal switch with manual reset. Alarm 8 - no depressurization the “no depressurization” alarm is indicating that there are problems with fume exhaust; this condition is encountered when the exhaust flue ...

  • Page 28

    Al 07 resettable thermal breaker the manual reset thermostat connected to the hopper. Reset the thermostat by pressing the button on the back of the stove. Combustion in the brazier is not optimal due to clogging or obstructions of internal stove ducts. Switch off the stove, clean the brazier and th...

  • Page 29: •

    Clean basket basket that needs cleaning if you use another type of pellets, even of the same brand, this may lead to differences in combustion that may result in greater ash deposits inside the bra- zier. Correct cleaning, daily, enables the stove to burn in an optimal manner and provide constant he...

  • Page 30

    Warranty warranty certificate ravelli srl would like to thank you for agreeing to buy one of our pellet stoves and invites you, the customer, to: • read the instructions for installation, use and maintenance of the stove. • note the warranty conditions reported below. The warranty form attached to t...

  • Page 31

    Alimentazione 230vac neutro +5 v fase alimentazione 230vac display candeletta n dep tsp encoder fumi encoder fum i serial/ termostato ext. Term ext. Opt. Encoder fumi gnd en c sonda fumi + sonda ambiente - sonda acqua pe f c s * asdas c s f coclea vent. Scambiatore vent. Fi wiring diagram dep=vacuum...

  • Page 32

    Note.

  • Page 33

    Note user manual o-ring 33.

  • Page 34

    Note 34.

  • Page 36

    Ravelli does not assume any responsibility for any errors in this booklet and considers itself free to make any variations to the features of its products without notice. Ravelli srl via kupfer, 31 - 25036 palazzolo sull’oglio / bs - italy tel. +39.030.7402939 fax. +39.030.7301758 internet: www.Rave...