    M7 gx quick start guide 1 raveon technologies corp. Rv-m7 g x u h f g p s t r a n s c e i v e r quick -s tart guide version b0 june 2008 rv-m7-uc-gx rv-m7-uc-gx-wx raveon technologies corporation 2780 la mirada drive, suite c vista, ca 92081 www.Raveontech.Com.

  • Page 2

    M7 gx quick start guide 2 raveon technologies corp. 1. Safety / warning information 1.1. Blasting caps and blasting areas to avoid possible interference with blasting operations, turn off this radio or remove the dc power when you are near electrical blasting caps or in areas posted: “ turn off two-...

  • Page 3

    M7 gx quick start guide 3 raveon technologies corp. Gps mode common usage default serial port baudrate output message description gps 1 transponder simple tracking, avl, security. 4800 gsv, gll transmit only in this mode. The receiver is off and gps is turned off between transmissions. This is the l...

  • Page 4

    M7 gx quick start guide 4 raveon technologies corp. 4. Electrical inputs and outputs the front panel of the m7 gx modem has these features: 1. Rf connector 2. Power led 3. Status led (receive data = green, tx = red) 4. 9-pin serial i/o connector 5. Dc power jack 4.1. Leds the status led visually sho...

  • Page 5

    M7 gx quick start guide 5 raveon technologies corp. 5. Rs232 serial i/o connector the rs232 9-pin serial i/o connector is a female 9-pin d- subminiature connector having the following pins configuration. It is pinned out so that it may be plugged directly into a computer or pc’s 9-pin com port. Fron...

  • Page 6

    M7 gx quick start guide 6 raveon technologies corp. This pin-out allows it to be directly plugged into a computer’s 9-pin serial port using a conventional 9-pin rs-232 serial cable. To connect it to a modem, or peripheral that has a serial port, you will need a “ null-modem ” cable. 6. Configuring t...

  • Page 7

    M7 gx quick start guide 7 raveon technologies corp. 6.4. Modem commands (short list. See technical manual for complete list) comm and command description parameters factory default atbd baud rate – sets serial com port baud rate (bps). Over-the-air (throughput) baud rate is set with atr2 command. 0 ...

  • Page 8

    M7 gx quick start guide 8 raveon technologies corp. Atpo rf power output . Set or show the rf power output setting. Value is in percent, from 0% to 100%. Use and rf wattmeter to confirm the power setting. 0-100 100 atr1 select cd pin output signal – cd may be rf carrier detect, or modem data detect....

  • Page 9

    M7 gx quick start guide 9 raveon technologies corp. 6.5. Gps additional commands the following commands are unique to the – gx version of the m7 . When you execute any of these commands, the new parameter is automatically stored in eeprom. Command command description parameters default athx singe-ho...

  • Page 10

    M7 gx quick start guide 10 raveon technologies corp. Repeats ids 0001 thru 0999). Slottime tdma slot duration. Configure the width of a tdma slot. 50ms increments. 50 - 1000 200 trigbits i/o change reporting. Which bits are used as transmission triggers. This is a hex number. Bit 0 is in0, bit 1 is ...

  • Page 11

    M7 gx quick start guide 11 raveon technologies corp. Hardware flow control.................... Off rf power output........................... 5 watts channel number selected ............. 1 position/status report interval ....... 10 seconds security key ................................. Raveon proxi...

  • Page 12

    M7 gx quick start guide 12 raveon technologies corp. Atmk the network address mask. Default is f000. This means this unit will receive all transmissions from any other unit with an id beginning with 0 (0001 thru 0999). Keyphrase enter a security key code. Use any word or phrase 1-16 characters long....

  • Page 13

    M7 gx quick start guide 13 raveon technologies corp. Txrate 10 ( configures it to report every 10 seconds whenever it is moves more than trigdx meters) 7.2. Device addressing security key the security key programmed into every m7 gx transponder ensures that only m7 gx transponders with the exact sam...

  • Page 14

    M7 gx quick start guide 14 raveon technologies corp. Each tdma time slot is 200ms long, and thus in 10 seconds, up to 50 m7 gx transponders may report position. These parameters are programmable, and may be re-configured based upon the type of system they are used in. Program the slot time with the ...

  • Page 15

    M7 gx quick start guide 15 raveon technologies corp. 9. Installation 1. Secure the m7 modem using the mounting holes on the side flanges of the unit. 2. Connect a dc power source to the dc in connection on the front of the modem. Use the supplied cable, or 18awg wire, and connect the red wire to +, ...

  • Page 16

    M7 gx quick start guide 16 raveon technologies corp. For technical assistance contact raveon at: raveon technologies corporation 2780 la mirada drive, suite c vista, ca 92081 760-727-8004 www.Raveontech.Com sales@raveontech.Com.