Raychem green leaf Installation Instruction - 8. Technical Specification
17
8. TECHNICAL SPECIFICATION
Supply voltage
230VAC, +10%, –15%, 50Hz
Power consumption (Stand-by)
3 VA
Relay output
230V, maximum 13A resistive load (max. 3000W)
Ambient temperature – operation
0 .. 40°C, 5-95% RH (non condensing)
Ambient temperature – transport
–10 .. +60°C
Temperature range, floor sensor
+5 .. +35°C
Temperature range, room sensor
+5 .. +40°C
Switching hysteresis
1°C (Factory settings adjustable between 0.5-2.0°C)
Control modes
Floor sensing
Room sensing
Room sensing with floor temperature limiter
Temperature control
Manual ON/OFF
Timer programme
Protection class
IP 20
Terminals
Max. 2,5 mm²
Floor sensor with 3 m cable
NTC, 10KΩ / 25°C
Maximum length of floor sensor Cable
100 m, 2 x 1,5 mm² (230VAC cable type)
Approvals
Type of action
1.B. (39)*
Control pollution degree
2 (49)*
Rated impulse voltage
4kV (75)*
Temperature for the ball pressure test
125°C (77)*
SELV limits realized
22 VDC (86)*
* According to the EN 60730-1 table 1
Our products satisfy the requirements
of the relevant European Directives.