Raychem QuickStat-TC Installation & Operation Manual - page 2
Installation
Important: This thermostat must be installed according to all national
and local electrical codes. The installation must be performed by
qualified personnel.
Locating the floor temperature sensor
The floor temperature sensor is installed under the floor surface. See
the QuickNet System Installation Manual (H57704), Section 6, for more
details. Perform the Sensor Resistance Test prior to terminating the floor
sensor to the thermostat. See the QuickNet System Installation Manual
(H57704), Section 7, for more details.
Wiring the thermostat
WARNING: TURN OFF THE POWER TO THE CIRCUIT AT THE MAIN
POWER PANEL TO AVOID ELECTRIC SHOCK.
WARNING: SHOCK HAZARD. TO PREVENT SHOCK, THE QUICKNET
FLOOR HEATING MAT MUST BE CONNECTED TO GROUND.
1. Remove the control module from the power base by loosening the
captive screw underneath the base.
2. Connect the floor
heating cold leads to
the load wires (two
inner wires) using the
supplied wire nuts.
3. Connect the power
supply leads to the
power base wires (two
outer wires) using the
supplied wire nuts.
4. Connect the floor
heating cold lead braid
(ground) to the supply ground in the electrical junction box.
5. Insert the floor sensor cable through one of the two openings on the
power base and connect to terminals 1 and 2 (no polarity). Position
the sensor cable such that it does not come in contact with the floor
heating wires.
6. Push the excess length of the wires back inside the electrical junction
box
7. Secure the power base to the electrical junction box using the
provided mounting screws
8. Verify the settings of the configuration switches on the back of the
control module. Default settings for the configuration switches are
highlighted below.
Important: If your system is installed underneath laminate or
engineered wood flooring, you MUST use AF mode with the default
settings. Note the factory default is AF mode.
No. Configuration
Up
Down
1
Display format
°F/12 hr
°C/24 hr
2
Early Start
1
Enable
Disable
3
Temperature control mode
2
F
AF
1
Early Start can be used in Automatic mode only. When this function is
enabled, the thermostat calculates the optimal time to start heating in
order to obtain the desired temperature by the set time. The thermostat
re-assesses the start time daily based on the previous day’s results.
Note: If you wish to use only 2 periods, set periods “1 and 4” or
periods “2 and 3”. Early Start will not work if you set periods “1 and
2” or periods “3 and 4”.
2
To select floor sensing mode, place the switch to the F position. To
select floor sensing and ambient sensing mode, place the switch to
the AF position and ensure that the remote temperature sensor is
connected to the thermostat. To select the A mode, place the switch in
the AF position and ensure that the remote temperature sensor is NOT
connected to the thermostat.
9. Install the control module onto the power base.
Control
module
Air
vents
Air
vents
Power
base
QuickStat-TC Installation & Operation Manual
2
Power
supply
Load / Floor heating mat
Supply
ground
Floor heating
cold lead
ground
Floor temperature sensor
Supply ground
Floor heating
cold lead
ground
400-115-052