  • Page 1

    Garage door opener model 3595rgds 3/4 hp for residential use install on sectional doors only this operator is intended for use only with i-beam rails. Owner’s manual ■ please read this manual and the enclosed safety materials carefully! ■ fasten the manual near the garage door after installation. ■ ...

  • Page 2

    2 introduction 2-5 safety symbol and signal word review ....................... 2 preparing your garage door ....................................... 3 tools needed .............................................................. 3 planning .................................................................

  • Page 3

    3 to prevent damage to garage door and opener: • always disable locks before installing and operating the opener. • only operate garage door opener at 120v, 60 hz to avoid malfunction and damage. To prevent possible serious injury or death: • always call a trained door systems technician if garage d...

  • Page 4

    4 sectional door installation planning identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may find it helpful to refer back to this page and the accompanying illustratio...

  • Page 5

    5 up ceiling mount onl y chassis support bracket chain spreader extension bracket (2) rail chain pulley bracket chain straight door arm section curved door arm section safety labels and literature 2 conductor bell wire white & white/red trolley header bracket the protector system ® (2) safety revers...

  • Page 6

    Washered bolt 5/16"-18x1/2" lock nut 6 assembly step 1 attach the rail to the motor unit to avoid installation difficulties, do not run the garage door opener until instructed to do so. • remove the bolt and lock nut from the top of the motor unit. • place rail onto the bolt mounted on the motor uni...

  • Page 7: Warning

    7 assembly step 4 tighten the chain • spin the inner nut and lock washer down the threaded shaft, away from the trolley. • to tighten the chain, turn outer nut in the direction shown. As you turn the nut, keep the chain from twisting. • when the chain is approximately 1/2" (13 mm) above the base of ...

  • Page 8

    8 installation step 1 determine the header bracket location sectional door only 1. Close the door and mark the inside vertical centerline of the garage door. 2. Extend the line onto the header wall above the door. You can fasten the header bracket within 4 feet (1.22 m) of the left or right of the d...

  • Page 9

    9 installation step 2 install the header bracket you can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements. Do not install the header bracket over drywall. If installing into masonry, u...

  • Page 10

    10 clevis pin 5/16"x2-3/4" ring fastener installation step 3 attach the rail to the header bracket • position the opener on the garage floor below the header bracket. Use packing material as a protective base. Note: if the door spring is in the way you’ll need help. Have someone hold the opener secu...

  • Page 11

    11 installation step 5 hang the opener three representative installations are shown. Yours may be different. Hanging brackets should be angled (figure 1) to provide rigid support. On finished ceilings (figure 2 and figure 3), attach a sturdy metal bracket to structural supports before installing the...

  • Page 12

    12 installation step 6 install the smart control panel ® locate door control within sight of door, at a minimum height of 5 feet (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors provided. Fo...

  • Page 13

    Trolley notice overhand knot emergency release handle rope trolley release arm 13 installation step 7 install the light • press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens. • install up to a 1...

  • Page 14

    14 installation step 9 electrical requirements to avoid installation difficulties, do not run the opener at this time. To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet. If the plug...

  • Page 15

    15 installation step 10 install the protector system ® the safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. Important information about the safety reversing sensor when properly connected and aligned, the sensor will detec...

  • Page 16

    16 floor mount (right side) wall mount (right side) door track mount (right side) indicator light lens lip sensor bracket door track sensor bracket extension bracket lens indicator light lag screw 1/4x1-1/2" inside garage wall indicator light sensor bracket lens extension bracket inside garage wall ...

  • Page 17

    Invisible light beam protection area safety reversing sensor safety reversing sensor connect wire to opener quick-connect terminals bell wire bell wire finished ceiling quick-connect terminals 3. To release or insert wire, push in tab with screwdriver tip 1. Strip wire 7/16" (11 mm) 2. Twist like co...

  • Page 18

    18 fiberglass, aluminum or lightweight steel garage doors will require reinforcement before installation of door bracket. Contact your door manufacturer for reinforcement kit. Installation step 11 fasten the door bracket follow instructions which apply to your door type as illustrated below or on th...

  • Page 19

    19 installation step 12 connect door arm to trolley sectional doors only • make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley. Slide the outer trolley back (away from the door) about 2" (5 cm) as shown in figures 1, 2 and 3...

  • Page 20

    20 adjustment step 1 adjust the up and down travel limits limit adjustment settings regulate the points at which the door will stop when moving up or down. To operate the opener, press the door control push bar. Run the opener through a complete travel cycle. • does the door open and close completel...

  • Page 21

    21 adjustment step 2 adjust the force force adjustment controls are located on the right side panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door. If the forces are set too light, door travel may be interrupted by nuisance reversals in ...

  • Page 22

    22 without a properly installed safety reversal system, persons (particularly small children) could be seriously injured or killed by a closing garage door. • safety reversal system must be tested every month. • if one control (force or travel limits) is adjusted, the other control may also need adj...

  • Page 23: Warning

    Operation 23 important safety instructions to reduce the risk of severe injury or death: warning 1. Read and follow all warnings and instructions. 2. Always keep remote controls out of reach of children. Never permit children to operate or play with garage door control push buttons or remote control...

  • Page 24

    24 additional feature when used with the 3-button hand-held remote to control the opener lights: in addition to operating the door, you may program the remote to operate the lights. 1. With the door closed, press and hold a small remote button that you want to control the light. 2. Press and hold th...

  • Page 25

    To open the door manually the door should be fully closed if possible. Pull down on the emergency release handle and lift the door manually. To reconnect the door to the opener, press the door control push bar. The lockout feature prevents the trolley from reconnecting automatically. Pull the emerge...

  • Page 26

    Having a problem? 1. The opener doesn't operate from either the door control or the remote control: • does the opener have electric power? Plug a lamp into the outlet. If it doesn't light, check the fuse box or the circuit breaker. (some outlets are controlled by a wall switch.) • have you disabled ...

  • Page 27

    27 having a problem? (continued) 11. The door reverses for no apparent reason and opener lights blink for 5 seconds after reversing: • check the safety reversing sensor. Remove any obstruction or align the receiving eye. See installation step 10. 12. The opener lights don’t turn on: • replace the li...

  • Page 28

    Smart control panel ® messages the following messages are contained within the smart control panel ® and may appear during the operations of the unit: meaning: this message will appear if the safety reversing sensors are out of alignment, if they are blocked or if the wiring is disconnected. To clea...

  • Page 29

    1. Press the prog button on the door control. 2. Press the prog button again to confirm learn mode. 3. Press the button on the hand-held remote* that you wish to operate your garage door. 4. When the motor unit lights blink, it has learned the code. If light bulbs are not installed, two clicks will ...

  • Page 30

    30 1. Press and release the “learn” button on motor unit. The learn indicator light will glow steadily for 30 seconds. 2. Within 30 seconds, enter a four digit personal identification number (pin) of your choice on the keypad. Then press and hold the enter button. 3. Release the button when the moto...

  • Page 31

    31 8 11 12 6 up ce ili ng mount onl y 9 7 10 13 14 1 3 4 2 5 1 3 4 5 2 installation parts repair parts rail assembly parts key part no. No. Description 1 4a1008 master link kit 2 41a2780 chain pulley bracket 3 41a3489 complete trolley assembly 4 3707ch 7' (2.1 m) rail assembly 3708ch 8' (2.4 m) rail...

  • Page 32

    Motor unit assembly parts 32 dn up brown wire (down) contact limit switch assy. Grey wire yellow wire (up) contact center limit contact drive gear 3 5 4 2 1 16 20 9 18 6 19 10 13 17 15 12 11 7 7 14 8 8 key part no. No. Description 1 41c5069 chassis support bracket assy. Kit 2 41a4208-2 chain spreade...

  • Page 33

    Closed open 33 accessories 374rgd 370lm 395lm 1702lm outside quick release: required for a garage with no access door. Enables homeowner to open garage door manually from outside by disengaging trolley. Remote light control: enables homeowner to turn on a lamp, television or other appliance from the...

  • Page 34

    Notes 34.

  • Page 35

    Notes 35.

  • Page 36: Raynor

    © 2011, the chamberlain group, inc. 114a3638b all rights reserved raynor ® garage doors service is on call our large service organization spans america installation and service information is as near as your telephone five days a week. Simply dial our toll free number: 1-800-472-9667 hours: (central...