RJM Amp Gizmo User Manual - Momentary Mode
Hold down the Switch 2 button while powering up the A
MP
G
IZMO
.
Keep holding the button until the LEDs flash. You are now in Invert
Mode.
While in Invert Mode, use the front panel buttons to light the LED of
any function that is inverted. Make certain no other LED is lit.
Once you’ve selected the inverted function’s associated button(s), press
the Write button. The A
MP
G
IZMO
is now in normal operational mode,
and the inverted functions should operate correctly.
Momentary Mode
Some devices require momentary-type switching, rather than the more
common latching-type switches. (A momentary switch changes
OFF/ON state by closing its contacts for a short time and then re-
opening them. In Momentary Mode, the A
MP
G
IZMO
switches will
close for 100 milliseconds before opening again.)
To enter Momentary Mode, hold down the Switch 3 button while
powering up the A
MP
G
IZMO
. Keep holding the button until the LEDs
flash. Use the front panel buttons to light the LED of any function that
needs to be momentary. Make certain that no other LED is lit.
Once you’ve selected the buttons for the momentary functions, press
the Write button. The A
MP
G
IZMO
is now in normal operational mode
and the momentary functions should operate correctly.
Group Mode
The Group feature allows you define a group of buttons where pressing
one button of the group turns that button on and turns all other buttons
in the group off. This is typically used for switches that control which
channel is selected on an amplifier. This prevents the A
MP
G
IZMO
from
trying to activate more than one amp channel at a time.
11