RO-MAN Thin Film Membrane Information
Permeate Flow Rate
Minimum Salt
Stabilized Salts
Gals/Day US
Litres/Day
Rejection (%)
Rejection (%)
100
380
96
98
75
283
96
98
50
189
96
98
36
136
96
98
Dimensions
L
I
D
Inches
CM
Inch
CM
Inches
CM
11.63
295
10.0
250
1.8
46
Recommended Operation Conditions
Maximum Operating Pressure
125 PSI (0.86 MPa)
Maximum Feed Flow Rate
2 GPM
Maximum Operating Temperature
113°F (45°C)
Maximum Feed Water Turbidity
1 NTU
Maximum Feed Water Silt Density Index (15min.) 5
Chlorine Tolerance
0
Feed Water pH Range
2-11
Minimum Brine Flow to permeate Flow Ratio
4:1
Temperature Correction Factor
Performance of the reverse osmosis membrane element is affected by two key factors, temperature of the feed water and the
net driving pressure across the element. These two factors must be taken into account before comparing or evaluating the
performance of the membrane element of a reverse osmosis system.
The higher the temperature, the more the product flow and vice versa. All reverse osmosis membrane elements and systems
are rated at 77º Fahrenheit (25ºCelsius).
To find the membrane permeate rate at different temperatures follow these steps:
1) Find the Temperature Correction Factor (TFC) from the table below.
2) Divide the rated permeate flow at 77º F by the TFC.
The result is the permeate flow at the desired temperature.
Feed Water
Temperature
Correction
ºC
ºF
Factor
Feed Water
Temperature
Correction
ºC
ºF
Factor
Feed Water
Temperature
Correction
ºC
ºF
Factor
5
41.0
2.58
6
42.8
2.38
7
44.6
2.22
8
46.4
2.11
9
48.2
2.00
10
50.0
1.89
11
51.8
1.78
12
53.6
1.68
13
55.4
1.61
14
57.2
1.54
15
59.0
1.47
16
60.8
1.39
17
62.6
1.34
18
64.4
1.29
19
66.2
1.24
20
68.0
1.19
21
69.8
1.15
22
71.6
1.11
23
73.4
1.09
24
75.2
1.04
25
77.0
1.00
26
78.8
0.97
27
80.6
0.94
28
82.4
0.91
29
84.2
0.88
30
86.0
0.85