S&W Production & Post Production HD1012 Installation Manual

Summary of HD1012

  • Page 1

    Installation manual.

  • Page 2

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production ii hd1012 installation manual for v3 software issue 1, revision 1, september 2003 © 1998-2003 snell & wilcox post production division the business and technology centre shire hill saffron walden...

  • Page 3: Safety

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page iii safety explanation of safety symbols this symbol refers the user to important information contained in the accompanying literature. Refer to users manual. This symbol indicates that hazardou...

  • Page 4

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production iv power cable supplied for the usa the equipment is shipped with a power cord with a standard iec molded free socket on one end and a standard 3-pin plug on the other. If you are required to re...

  • Page 5

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page v maintenance & repair there are no user serviceable parts within either the mainframe or the control panel. In the unlikely event of an equipment failure contact the snell & wilcox post product...

  • Page 6

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production vi emc standards this unit conforms to the following standards: bs en 55103-1 : 1997 electromagnetic compatibility, product family standard for audio, video, audio-visual and entertainment light...

  • Page 7

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page vii contents section a - installation ........................................................................................... 1 introduction ....................................................

  • Page 8

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production viii list of diagrams wiring of iec mains inlet connectors ................................................................... 4 control panel - rear view...........................................

  • Page 9: Installation

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 1 section a installation.

  • Page 10

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 2 introduction these installation instructions provide a guide to the installation of the hd1012 high-definition switchers. On delivery of the system the equipment is supplied in dedicated packa...

  • Page 11

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 3 location and environment environmental considerations the ambient temperature for all the supplied equipment should not exceed the limits of 5 and 35 degrees c. At a relative humidity of 10 to...

  • Page 12

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 4 location and environment - continued power supplies the switcher mainframe and/or control panel may be fitted with dual power supplies. In each case the unit will work happily with a single po...

  • Page 13

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 5 system interconnection introduction your system has been set up and tested before shipment. Installation normally consists of siting and interconnecting the system components, connecting video...

  • Page 14

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 6 system interconnection - continued button bus multi control button bus multi control is a facility which allows one switcher control panel to control two switcher mainframes simultaneously, so...

  • Page 15

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 7 system interconnection - continued display 2 display 1 vga mainframe 10 base t rs232 model no. Serial no. Made in saffro n walden, essex, uk. Snell & wilcox 115/230 v 60/50 hz 1.0/0.5 a t 250v...

  • Page 16

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 8 system interconnection - continued cp1512 dimensions in mm 819 824.

  • Page 17

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 9 system interconnection - continued hd1000 switcher mainframe - rear panel & connectors.

  • Page 18

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 10 system interconnection - continued inputs connect up to 12 hd-sdi inputs to the 12 serial inputs of the switcher mainframe. Sources can be either video or key. Outputs connect the program, cl...

  • Page 19

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 11 system interconnection - continued multiple monitor mode multiple monitor mode is a set-up that allows monitoring of m/e program and preview as well as p/p program and preview. Four manitors ...

  • Page 20

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 12 system timings referencing the switcher can be genlocked to any of its 12 hd-sdi inputs or to tri-level sync. On the ref analogue in loop-through connectors, selectable from the configure-sys...

  • Page 21

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 13 system timings - continued referencing - system delays the total delay through the system depends partly on the current standard but mainly on which cards are fitted to the hd1000 mainframe. ...

  • Page 22

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 14 control ports and protocols ports the switcher mainframe has ethernet, serial and tally & gpi i/o ports. The ethernet ports are used for connection between the mainframe and the control panel...

  • Page 23

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 15 control ports and protocols - continued gvg 4000 this protocol allows an editor capable of controlling a gvg 3000 or 4000 switcher to drive the p/p bus of the switcher. Learn and recall of dm...

  • Page 24

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 16 control ports and protocols - continued there are three variants of the gvg-3000/4000 protocol. They are identical except for the way that aux and preview busses are assigned. The bus name in...

  • Page 25

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 17 control ports and protocols - continued sony dvs crosspoint allocation is shown in the table below. When a source can be accessed via two or more different values, the value returned on a sta...

  • Page 26

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 18 control ports and protocols - continued using a sony bve-9100 editor there is a fairly common problem when using the bve-9100 editor and s & w switchers whereby the switcher appears to be act...

  • Page 27

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 19 control ports and protocols - continued to adjust this setting on the bve-9100 step-by-step: 1. Press shift-setup. 2. Press f3 idc. 3. Cursor down to the sw/mon entry in the idc list 4. Press...

  • Page 28

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 20 control ports and protocols - continued vtr using the sony vtr (p2) protocol, the switcher emulates, specifically, a sony bvh-2000. The timeline is treated as length of videotape in a virtual...

  • Page 29

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 21 control ports and protocols - continued s & w tally this protocol transmits detailed tally information every field for use by external intelligent tally systems. The protocol used is specific...

  • Page 30

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 22 control ports and protocols - continued general purpose inputs & outputs overview standard system the switcher mainframe has eight general purpose inputs and 32 outputs. The action of each of...

  • Page 31

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 23 control ports and protocols - continued the outputs there are thirty-two general purpose outputs, located on the three tally connectors (25 way d-type) on the rear of the switcher mainframe. ...

  • Page 32

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 24 control ports and protocols - continued programming the inputs the gpi functions are programmed in the gpi menu found under the configure - user menu. The left screen shows the, standard, eig...

  • Page 33

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 25 control ports and protocols - continued programming the outputs the gpo functions are programmed in the gpo menu which is accessed from the gpi menu by f1r. The rotary controls are used to se...

  • Page 34

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 26 control ports and protocols - continued multiple conditions the gpo active state may be conditional on more than one occurrence. The rightside buttons f1r to f4r set-up the conditions and the...

  • Page 35

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 27 control ports and protocols - continued list of gpo occurrences the following is a complete list of the system occurrences which may be assigned to a gpo. Note this list includes the occuranc...

  • Page 36

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 28 other installation procedures setting the real-time clock it is recommended that you set the real-time clock at installation time. To do this, press the config button near the bottom-left of ...

  • Page 37

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 29 other installation procedures – continued remote allocation of aux sources the switcher auxiliary outputs may have their sources allocated from one or more remote panels rather than from the ...

  • Page 38

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 30 other installation procedures – continued quartz panels the quartz electronics cp3201 - s7 remote panel may be used to switch signal sources to the switcher auxiliary outputs from a location ...

  • Page 39

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 31 other installation procedures – continued 1. All aux o/ps controlled from one panel. The quartz and pro-bel remote panels have buttons which select the required aux output. The panels are con...

  • Page 40

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 32 other installation procedures – continued diode buffer 9 pin “d”- type female connector (to extender) wiring of pins between connectors 9 pin “d”- type male connector (to control panel) descr...

  • Page 41

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 33 other installation procedures – continued interconnection & set-up the diode buffers connect directly to the computer port of the quartz panel or the loop port of the pro-bel panel. A standar...

  • Page 42

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 34 connector pinouts mainframe rs-422 connector pinout 9-way female d-type function 1 frame ground 2 transmit a (tx-) 3 receive b (rx+) 4 receive common 5 6 transmit common 7 transmit b (tx+) 8 ...

  • Page 43

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 35 connector pinouts - continued switcher gpis / gpos 25 way d-type connectors - switcher mainframe rear panel tally 1-12 tally 13-24 tally 25-32 & gpi 1-8 pin signal pin signal pin signal 1 gpo...

  • Page 44

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 36 cable wirings control panel to lcd touch screen 15-way cable control panel 15-way sub-d-type male cable colour lcd touch screen 15-way sub-d-type male lcd_lcds0– lcd_lvds1– pin 1 pin 2 pair 1...

  • Page 45

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 37 cable wirings - continued control panel to lcd touch screen 44-way cable control panel 44-way sub-d-type male cable colour lcd touch screen 44-way sub-d-type male gnd pin 1 white-blue pin 1 g...

  • Page 46

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 38 system with integrated router an integrated router may by used with the hd1012 system to increase the number of available sources. This router may be the snell & wilcox hd1132 or a supported ...

  • Page 47

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 39 router / mainframe connections diagram 1 2 3 4 5 6 7 8 9 10 11 59 60 61 62 63 64 ref loop source source source source 1 2 59 60 rs422 aux 5 aux 6 aux 7 aux 8 12 1 2 1 2 3 4 5 6 7 8 9 10 11 12...

  • Page 48

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 40 deliberately blank.

  • Page 49: Specifications

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 41 section b specifications.

  • Page 50

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 42 the following specifications cover the hd1000 switcher mainframe and cp1512 control panel. Television standards television standards multi-standard, including, but not necessarily limited to,...

  • Page 51

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 43 inputs number of video inputs 12 x high definition serial digital interface (hd-sdi) each on 1 x bnc reference input on-line switchable between: from any (hd-sdi) video input. Analogue hd syn...

  • Page 52

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 44 outputs program outputs 2-off hd-sdi each on 1 x bnc, on-line switchable between 8 & 10 bits. Clean program outputs 2-off hd-sdi each on 1 x bnc, on-line switchable between 8 & 10 bits. Previ...

  • Page 53

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 45 control interfaces - mainframe control panel 10 base t-x on 1 x rj45 connector. Network #1 10 base t on 1 x rj45 connector. 10 base 2 on 1 x bnc. Network #2 (optional) 10/100 base t on 1 x rj...

  • Page 54

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 46 control interfaces - control panel main chassis mainframe 10 base t on 1 x rj45 connector. Built-in display 1 x 25-way female d-type. 1 x 9-way female d-type. External keyboard pc compatible ...

  • Page 55

    Www.Snellwilcox.Com s&w production & post production hd1012 installation manual – v3, issue 1, rev 1 page 47 physical - hd1000 switcher mainframe size height width depth 8u (rack units) ~ 356 mm. 19 inches nominal ~ 485 mm including brackets. 24 inches nominal ~ 610 mm including connectors weight 48...

  • Page 56

    Www.Snellwilcox.Com page hd1012 installation manual – v3, issue 1, rev 1 s&w production & post production 48 power supply switcher mainframe two fully-independent hot-swappable psu modules, with separate mains power feeds via 2 x iec socket. Control panel two fully-independent psu modules, with sepa...

  • Page 57

    Www.Snellwilcox.Com s&w production & post production end of manual.