SABINE Smart Spectrum SWM4000 Series Operating Manual - page 8
8
Sabine SWM4000 Smart Spectrum
®
Wireless
© 2011 Sabine
, Inc.
Changing Batteries
Expected life for an Alkaline battery is approximately 8 hours.
Change batteries when the battery bar in LCD display is empty, as shown below:
Antenna (replaceable)
Audio gain adjustment switch
IR port - Receives infrared beam to synchronize frequencies.
When using multiple systems, only one transmitter IR port should be exposed at a time.
LCD screen
Battery cover (slide both clips down to open)
TA4-F microphone input jack
On-off switch
On-off / on-mute / on-on switch (located under the case, above the battery compartment).
Use a pencil to select option. Switch is hidden to protect from accidental nudge.
Up
Down
Select
Clip the transmitter to a belt until the belt is pressed
against the base of the clip.
1. With the power on, press and hold the select button until the GROUP and CHANNEL
displays begin to alternate.
2. To change the group setting, release the select button while GROUP is flashing.
(While GROUP is flashing, pressing up or down increases/decreases the group setting by one.)
3. Press select button to switch between GROUP and CHANNEL settings.
Indicates charge remaining in transmitter batteries.
Programming the Beltpack Transmitter
Controls
B5
B1
B2
B3
B4
B6
B7
B8
B9
SW45-T Beltpack Transmitter
Wearing the Beltpack Transmitter
B1
B4
B7
B8
B2
B5
B6
B9
SW45-T
B1
B7
B2
B6
Top view
B10
B3
B10
B11
B11