3.9 Tips and tricks
In heavy rain the electric housing (rear pot with cable
connection and switch) should be covered over, e.g. with a
plastic sheet. Although this prevents the electronic equip-
ment from cooling down, the surroundings usually suffice
to ensure that there is no excess increase in temperature.
An excess temperature protection integrated into the elec-
tronics ensures protection of the luminaire and switches it
off when necessary (see 3.8 LED display).
4
Service / Troubleshooting
The device does not contain any parts which require servicing.
The following troubleshooting table is to help you locate any
possible fault:
Cause, remedy
Bulb is either defect or has been wrongly
inserted; if not applicable, contact
Customer Service;
Power source below 9V or reverse poled or
connecting cable / plug defect or not pro-
perly plugged in.
Power source too low, between 9-11V (bat-
tery discharged) or switching off of electro-
nics due to excess temperature.
Fault, symptom
No ignition spark in the bulb after
switching on:
The green LED illuminates in
switch position “TEST”.
The green LED does not illuminate
in switch position “TEST”.
The red LED flashes when in
switch position “TEST”.