Saeco Incanto Classic Service Manual - Esc
INCANTO S-CLASS
5. SERVICE PROGRAMME
Saeco International Group
REV.1 FEB.2005
Page 15/18
4.2. Diagnosis menu
(Incanto sirius)
The values below can be read and adjusted in the diagnosis menu as shown in the table.
Access:
Access from the standby mode (press MENU/OK) by keeping the EXPRESSO and HOT
WATER button pressed, whilst pressing briefly the ON button.
From Version:
2.00.1
Access from the standby mode (press MENU/OK) by keeping the EXPRESSO and HOT
WATER button pressed, whilst keeping the ON button pressed for an extended time.
Changing programme values:
Access appropriate item using the OK button.
Change value with ARROW buttons
Save value by using the OK button.
Programme table (diagnosis menu):
Function/Standard
Setting range
Increment
Comments
EXPRESSO LUNGO
No. of PULSES 600
50 - 1,000 Pulses
+/- 1
EXPRESSO
No. of PULSES 200
50 - 1,000 Pulses
+/- 1
COFFEE
No. of PULSES 360
50 - 1,000 Pulses
+/- 1
Number of flow meter pulses for
each saved cup fill volume, where
300 pulses correspond to approx.
100 ml.
----HEATING----
PARAMETER K1 8
1 - 50
+/- 1
Do not change!
----HEATING----
PARAMETER K2 30
1 - 50
+/- 1
Do not change!
ESC
OK
Steam + hot water button/ Left arrow
Expresso lungo button/ESC
Coffee button
Aroma selection/powder coffee/ right arrow
Menu/OK button
Expresso button