Sailor H412 User & Installation Manual - Status and Message Log
14
Status and Message Log
Status log
A status log is maintained in the Iridium SSAS Box to provide
information to the user about failed connections to the GPS and the
Iridium Transceiver. The status log stores the last 10 registered failed
connections.
The information for each registration is: Date, time and a description
e.g.:
”
19-11-2003 15:55 No contact with Iridium”.
If date and time are not available then X is shown instead e.g.:
”xx-xx
-xxxx xx:xx No contact with Iridium”.
The status log can be retrieved via the Service PC as a HTML page.
Message log
A message log is maintained in the SSAS control unit to provide
information to the user about the incoming SMSITSPollReq and
SMSAlarmReset messages.
The message log stores the last 10 registered message of each
type.
The information for each registration is: Date, time, description and
phone number e.g.:
”19-11-2003 13:09 SMSAlarmReset received from phone number
+88 10 31 01 23 45
”.
If date and time are not available then X is shown instead e.g.:
”xx-xx
-xxxx xx:xx SMSAlarmReset received from phone number
+88 10 31 01 23 45
”.
The message log can be retrieved via the LAN interface as a HTML
page.
Test Procedure
To test that the installation is successful the following procedure
must be followed.
The test is done by sending messages to an Email address.
Any Email address can be used i.e. your own or e.g. the ship owners
office.
If the ship has Email access you can use this with better result since
you can verify the message your self.
When using a remote Email address you shall have someone
helping you at the recipient end.
0424
Step 1
Connect the Ethernet LAN cable to the RJ45 connector on the
Iridium SSAS Box.
Step 2
Set up the configuration table in the Iridium SSAS Box to have only
one recipient. Type the Email address in the field “Alarm Email
address 1”
Press the button “configure SSAS”
Step 3
Press the first alert activation button for minimum 2 seconds.
Check that the light in the test button turns on or off according to the
settings.
Step 4
Press the test button for resetting the alert.
Check that the light in the test button turns on or off according to the
settings.
Step 5
Check that the Security Alert and Normal mode messages have
been received at the recipient. You can check the messages on the
ship Email client or you can call the recipient to confirm the delivery.
Check that all details in the Security Alert message are correct.
Step 6
Press the second alert activation button for min. 2 seconds.
Check that the light in the test button turns on or off according to the
settings.
Step 7
Press the test button for resetting the alert.
Check that the light in the test button turns on or off according to the
settings.
Step 8
Check that the Security Alert and Normal mode messages have
been received at the recipient. You can check the messages on the
ship Email client or you can call the recipient to confirm the delivery.
Check that all details in the Security Alert message are correct.
The system test is completed.
After the test the E-mails and phone numbers for alert recipients
shall be entered at the configuration page.
IMPORTANT:
It is the ship’s commanding officers responsibility that the system is
checked with respect to the recipients of alarm messages. Run the
test mode and check with the recipients that they have received the 2
test messages and 1 normal mode message.