Salcom Protocol
Salcom protocol takes the basic form: PPXXXXXXXsLsMMMMMM
P
is either CA (512 baud alpha), CN (512 baud numeric), ca (1200 baud alpha), or cn
(1200 baud numeric).
X
is a 7 digit RIC code.
S
is a space.
L
is a digit (1 to 4 beep level)
M
is the message payload (up to 240 characters).
CA ________________________________________________________________
Usage:
CA
Description: Call alphanumeric pager
Example:
CA1119358 1 Please return to reception
Response:
CA11193581
CN ________________________________________________________________
Usage:
CN
Description: Call numeric pager
Example:
CN1119358 1 777
Response:
CN11193581
RES ________________________________________________________________
Usage:
RES
Description: Reset 12-38 microcontroller
Example:
RES
Response:
SALCOM 12-38-0000 VX.XX