Salicru SPS.ONE User Manual

Other manuals for SPS.ONE: User Manual

Summary of SPS.ONE

  • Page 1

    Sps.One uninterruptible power supply (ups) user's manual.

  • Page 2

    2 salicru.

  • Page 3

    3 general index 1. Introduction. 1.1. Acknowledgement letter. 2. Information for safety. 2.1. Using this manual. 2.1.1. Conventions and used symbols. 3. Quality and standard guarantee. 3.1. Declaration of the management. 3.2. Standard. 3.3. Environment. 4. Presentation. 4.1. Views. 4.1.1. Equipment ...

  • Page 4

    4 salicru salicru 1. Introduction. 1.1. Acknowledgement letter. We would like to thank you in advance for the trust you have placed in us by purchasing this product. Read this instruction manual carefully in order to be familiar with its contents, be- cause as much you understand and know the equipm...

  • Page 5

    5 2. Information for safety. 2.1. Using this manual. The user's manual of the equipment is available in our website for the customers, being able to be on-line readed or down- loaded as appropiate. Together with the own document, it is needed to have access to the ek266*08 document as regards to «sa...

  • Page 6

    6 salicru 3. Quality and standard guarantee. 3.1. Declaration of the management. Our target is the client’s satisfaction, therefore this manage- ment has decided to establish a quality and environmental policy, by means of installation a quality and environmental management system that becomes us ca...

  • Page 7

    7 4. Presentation. 4.1. Views. 4.1.1. Equipment views. Figures 1 and 5 show the illustrations of the equipments ac- cording to the model. Nevertheless and as the product is in constant evolution, some discrepancies or small contradictions can arise. So, if any questions, the labels in the own equipm...

  • Page 8

    8 salicru 4 5 6 3 1 3 1 8 2 7 5 6 3 4 3 sps.500.One, sps.700.One and sps.900.One sps.1100.One sps.1500.One and sps.2000.One fig. 3. Rear views with uk outlets. 4 5 6 3 1 7 3 1 8 7 5 6 3 2 7 4 3 sps.500.One, sps.700.One and sps.900.One sps.1100.One sps.1500.One and sps.2000.One fig. 4. Rear views wit...

  • Page 9

    9 4.1.2. Legend corresponding to the equipment views. 1. Input power cord with power plug in its end. 2. Iec inlet to supply the equipment (models with no power cord 1 only). 3. Outlets. 4. Usb communication port. 5. Rj input connector, to protect the overvoltages in the modem or telephone lines. 6....

  • Page 10

    10 salicru 5. Installation . • read and respect the safety information, described in section 2 of this document. To obviate some of the indications stated in it, can cause a serious or very se- rious injuries to persons in direct contact or in the vicinity, as well as breakdowns in the equipment and...

  • Page 11

    11 • with the monitoring software installed in the pc, the ups start up / shutdown can be set, as well as to follow up its status. Follow the next steps before downloading and installing the monitoring software: 5.6. Download and installation of the software. • the monitoring software downloading is...

  • Page 12

    12 salicru 6. Troubleshooting guide. Use the following table to solve the minor problems that can be found: problem possible cause solutions no led is on in the front panel. Low battery. Charge the ups for 6 hours at least. Battery fault. Replace the battery by another of the same type. Ups is not o...

  • Page 13

    13 7. General technical specifications. Model 500 700 900 1100 1500 2000 power(va) 500 700 900 1100 1500 2000 power (w) 250 360 480 600 900 1200 technology line-interactive input voltage 220 / 230 / 240 v ac. Range 162-290 v ac. Nominal frequency 50 / 60 hz. Frequency autosensing yes. Stabilization ...

  • Page 14

    14 salicru : ............................................................................................................................................................................................................. ....................................................................................

  • Page 15

    15 : ............................................................................................................................................................................................................. ............................................................................................

  • Page 16

    Avda. De la serra 100 08460 palautordera barcelona tel. +34 93 848 24 00 902 48 24 00 fax +34 93 848 11 51 salicru@salicru.Com salicru.Com www.Linkedin.Com/company/salicru @salicru_sa branches and technical support & services (t.S.S.) barcelona bilbao gijÓn la coruÑa las palmas de g. Canaria madrid ...