Salus VS10BRF User Manual

Other manuals for VS10BRF: Installer's/user's Manual
Manual is about: 4 in 1 Digital Thermostat RF

Summary of VS10BRF

  • Page 1

    4 in 1 digital thermostat rf models:vs20wrf and vs20brf vs10wrf and vs10brf i n s ta l l e r / u s e r m a n u a l it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:35 stron.

  • Page 2

    02 vs20wrf and vs20brf installer manual contents 1 x installer / user manual vs10wrf 4x aaa batteries vs20brf fixing screws contents box contents introduction product compliance system options overview installation parameter settings error codes user guide installers notes warranty box contents icon...

  • Page 3

    Product compliance & safety information introduction thank you for purchasing the salus 4 in 1 room thermostat it must be used with the co10rf zigbee coordinator. The zigbee coordinator allows communication with other devices in the it600 rf system range. Other zigbee devices include wiring centre, ...

  • Page 4: 230V Ac

    Product compliance & safety information sources of danger the thermostat must be disconnected from mains supply before removing the cover. Emergency switch off the voltage to the individual thermostat wring centre or complete system. Installer parameter settings the salus vs10 and vs20 are equipped ...

  • Page 5: Ufh Manifold

    Vs20wrf and vs20brf installer manual 05 system overview - configuration options programmable room thermostat (prt) the unit can be configured to either one of the following * grouping and timer option only available when used with wiring centre. 1 ufh manifold wiring centre radiator boiler hot water...

  • Page 6

    System overview - configuration options 06 vs20wrf and vs20brf installer manual programmable room thermostat (prt) when configured for prt (see page 32) it mainly works by itself and allows the user to have separate time and temperature control of each zone on the wiring centre, radiator valve or sy...

  • Page 7

    System overview - zigbee coordinator vs20wrf and vs20brf installer manual 07 zigbee coordinator required for communication between these devices. Kl10rf vs10 / vs20rf trv10rf rx10rf co10rf sy stem overvie w it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:36 stron.

  • Page 8

    08 vs20wrf and vs20brf installer manual system overview - it600 system the thermostat can communicate with all these it600 devices system receiver configured to boiler receiver. Refer to system receiver manual rx10rf. System receiver configured to one room receiver rx2. Refer to system receiver rx10...

  • Page 9

    System overview - hot water option when the unit is configured as a hot water timer (see page 32) there are two methods of connecting the cylinder thermostat. Unit configured to hot water timer. Cylinder thermostat options 1 connected direct to wc (default) 2 connected direct to vs10/20rf (requires ...

  • Page 10

    System overview - hot water option 1 connected direct to wc (default) for convenience there is a unique built in option allowing the cylinder thermostat to be connected to either the hw timer or wiring centre. Please refer to note 1 on wiring centre guide and pages 15 and 20 for more information. 10...

  • Page 11

    Vs20wrf and vs20brf installer manual 11 installation – thermostat mounting not to be positioned on an exterior wall. Mounting position and installation to ensure trouble free operation and efficient control, the unit is best positioned in a draft free area and at 130cm from the floor. Do not positio...

  • Page 12

    12 vs20wrf and vs20brf installer manual carefully remove the front housing. Installation – thermostat mounting vs20wrf 1 3 2 60mm it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:36 stron.

  • Page 13

    Installation – terminal connections vs20wrf understanding your terminal connections rear of unit sensor terminals can be used for external air, floor sensor when configured as thermostat. Can also be used for cylinder thermostat when configured for hw. See page 57. 1 1 vs20wrf and vs20brf installer ...

  • Page 14

    Installation – thermostat external sensor vs20wrf note: if you are using an external sensor, the unit has to be configured for external air sensor or floor protection sensor please see device parameter setting page 57. Salus external sensor (sold separately) 14 vs20wrf and vs20brf installer manual i...

  • Page 15

    Installation – hot water timer cylinder thermostat vs20wrf note: the unit can be configured for cylinder thermostat or connected to the hot water timer. Please see device parameters page 57. For additional wiring centre information refer to note 1 on wiring centre guide. Hw timer connected cylinder ...

  • Page 16

    Installation – thermostat mounting vs20wrf 1 2 3 4 once you have connected your choice of external sensor (if applicable) insert batteries note: please proceed to page 23 16 vs20wrf and vs20brf installer manual it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:36 stron.

  • Page 17

    Carefully remove the front housing. Installation – thermostat mounting vs10wrf 1 3 2 60mm vs20wrf and vs20brf installer manual 17 inst alla tion it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:36 stron.

  • Page 18

    Installation – terminal connections vs10wrf understanding your terminal connections rear of unit power terminals 230 vac used for supplying power to the unit. 230v supply can be sourced from the wiring centre or any convenient source. Sensor terminals can be used for external air, floor sensor when ...

  • Page 19

    Installation – thermostat external sensor vs10wrf note: if you are using an external sensor, the unit has to be configured for external air sensor or floor protection sensor please see device parameter setting page 57. Vs20wrf and vs20brf installer manual 19 salus external sensor (sold separately) i...

  • Page 20

    Installation – hot water timer cylinder thermostat vs10wrf note: the unit can be configured for cylinder thermostat or connected to the hot water timer. Please see device parameters page 57. For additional wiring centre information refer to note 1 on wiring centre guide. Hw timer connected cylinder ...

  • Page 21

    Installation – thermostat mounting vs10rf check that the wiring is completed for: 1 2 please use the screws provided ensure the orientation arrow is pointing upwards. Power terminals sensor terminals (if applicable) you are ready to secure the rear housing to the wall box vs20wrf and vs20brf install...

  • Page 22

    Installation – thermostat mounting 1 fit the front housing to the rear housing align the front housing at the bottom edge. 2 lightly press until you hear a positive click. Ensure the pin connections are aligned 22 vs20wrf and vs20brf installer manual it600 vs20w - installer - user manual 011_layout ...

  • Page 23

    Installation – lcd graphics icon function box means to select the mode e.G. Means the current setpoint is hi temp, means the hi temp is not selected. Sunny: hi comfortable temperature. Cloudy: middle comfortable temperature. Moon: low comfortable temperature. Programmable thermostat program mode ind...

  • Page 24

    Installation – lcd graphics icon function heat indicator: indicates heat is required. Cool mode indicator: indicates cooling is required (if applicable) temperature indicator: display the room temperature. Display the set-temp. Also used to show the other information. Temporary manual override indic...

  • Page 25

    Installation – lcd graphics icon function hot water (hw) indicator: unit has been configured for hw timer. Hot water (hw) indicator: indicates that there is hot water demand. Hw program mode indicator: indicates program is running. Hw mode indicator: mode for 1 period of hw a day, from program 1 on ...

  • Page 26

    Installation – lcd graphics icon function floor sensor probe indicator show only when air + floor sensor is connected. Low battery indicator: batteries need to be replaced. Setting indicator: indicate the unit is in setting mode when program setting. Indicate the manual mode. Keylock indicator: show...

  • Page 27

    Installation – user interface key function 1. Increase or decrease setpoint temperature. 2. Increase or decrease day, clock, timer, party, holiday and boost. 3. Select installer parameter value. 1. Mode selection. 2. Long press to return to home display without saving. 3. Short press to return to th...

  • Page 28

    Installation - graphics key 28 vs20wrf and vs20brf installer manual press once press x amount of times hold for five seconds flashing xx short press to save and long press to save and exit short press to back up it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:36 stron.

  • Page 29

    Installation – first power up vs20wrf and vs20brf installer manual 29 inst alla tion it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:36 stron.

  • Page 30: System Setup Checklist

    Installation - system setup system setup checklist 1 the zigbee coordinator must be in pairing mode. Before starting the pairing, make sure the light is flashing on the coordinator by holding the button for 5 seconds. For more information refer to the coordinator instruction manual. 2 the device tha...

  • Page 31

    Installation – system parameters sx function system setting definition default so1 system unit 0 programmable stat (prt) type 1 digital thermostat 0 2 hw timer s02 what does unit 0* it600 wiring centre* communicate 1 it600 radiator valve 0 within the it600 2 system receiver set for rx2 system 3** sy...

  • Page 32: Selecting What Type of Unit

    Installation - system setup 32 vs20wrf and vs20brf installer manual selecting what type of unit selecting what unit to pair with use or to select the type of unit. After selection has been made, press to confirm. Use or to select the type of unit to pair with. Programmable stat (prt) digital thermos...

  • Page 33: Checklist

    Installation - pairing with wiring centre wiring centre checklist 1 the zigbee coordinator must be in pairing mode. 2 ensure the wiring centre and optional system receiver (configured to rx1) for remote boiler switch are powered up. Note: the wiring centre and system receivers will automatically joi...

  • Page 34

    Installation - pairing with wiring centre 34 vs20wrf and vs20brf installer manual use to select the wiring centre number to pair with. If you are using groups, use to select group number of each group required. If unit is stand alone then please select -- group 1 group 1 it600 vs20w - installer - us...

  • Page 35

    Installation - pairing with wiring centre long press to exit to home screen or continue to change device settings. Refer to page 57. Vs20wrf and vs20brf installer manual 35 use or to select the wiring centre zone number 1 to 8. Pairing with w c it600 vs20w - installer - user manual 011_layout 1 07.0...

  • Page 36

    36 vs20wrf and vs20brf installer manual installation - testing the pairing with the rf wc use to increase temperature to 30ºc and then press use to decrease temperature to 10ºc and then press if you are using the optional system receiver configured to rx1 please check that the green light goes on wh...

  • Page 37: Checklist

    Vs20wrf and vs20brf installer manual 37 installation - pairing the radiator valve(s) radiator valves checklist 1 the zigbee coordinator must be in pairing mode. 2 ensure that the radiator valves are in pairing mode (refer to trv10rf manual). A maximum of 3 radiator valves can be used with 1 thermost...

  • Page 38

    38 vs20wrf and vs20brf installer manual installation - pairing with radiator valve press to start the pairing process. It600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:37 stron.

  • Page 39

    Long press to exit to home screen or continue to change device settings. Refer to page 57. Vs20wrf and vs20brf installer manual 39 installation - pairing with the radiator valve once all trv’s have paired press the pre fix number on the trv will change as the trv(s) pair. Pairing with trv it600 vs20...

  • Page 40

    40 vs20wrf and vs20brf installer manual installation - testing rf pairing use to increase temperature to 30ºc and then press use to decrease temperature to 10ºc and then press if you are using the optional system receiver configured to rx1 please check that the green light goes on when the temperatu...

  • Page 41: Checklist

    Vs20wrf and vs20brf installer manual 41 installation - pairing with system receiver rx2 system receiver configured to rx2 single room receiver. Checklist 1 the coordinator must be in pairing mode. 2 the system receiver (rx2) is powered up and the red led is steady. Refer to rx10rf manual. 3 if you a...

  • Page 42

    Installation - pairing with system receiver rx2 42 vs20wrf and vs20brf installer manual it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:37 stron.

  • Page 43

    Installation - testing pairing with system receiver rx2 long press to exit to home screen or continue to change device settings. Refer to page 40. Vs20wrf and vs20brf installer manual 43 use to increase temperature to 30ºc and then press green led on green led off use to decrease temperature to 10ºc...

  • Page 44: Checklist

    Installation - pairing with system receiver rx1 only checklist 1 the coordinator must be in pairing mode. 2 the system receiver (configured to rx1) is powered up and the red led is steady. The system receiver will auto join the zigbee network on power up when the zigbee coordinator is in pairing mod...

  • Page 45

    Installation - pairing with system receiver rx1 only vs20wrf and vs20brf installer manual 45 pairing with r x1 it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:37 stron.

  • Page 46

    46 vs20wrf and vs20brf installer manual installation - testing pairing with system receiver rx1 only long press to exit to home screen or continue to change device settings. Refer to page 57. Use to increase temperature to 30ºc and then press use to decrease temperature to 10ºc and then press green ...

  • Page 47

    Installation - modifying system parameters if you have made an error or need to change your system parameters please follow steps below. This should only be done by your installer. Vs20wrf and vs20brf installer manual 47 inst alla tion press all three buttons simultaneously it600 vs20w - installer -...

  • Page 48

    Unit will follow power up sequence on page 29. You are now ready to enter or change your system parameters. Refer to page 31. 48 vs20wrf and vs20brf installer manual installation - modifying system parameters it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:37 stron.

  • Page 49

    Press again for 1 second to cancel identify. Identify mode will time out after 10 minutes. To check that the complete system is communicating and has been configured correctly, you can use identify mode. Using identify from the coordinator will show all products that are connected to your system. In...

  • Page 50

    Installation - checking system configuration prt prt press tick to cancel identify. Identify mode will time out after 10 minutes. System has no grouping to check that the relevant system is communicating and has been configured correctly, you can use identify mode. Prt prt prt prt prt please follow ...

  • Page 51

    Group control thermostat system has grouping prt please follow step 1 on page 47. When in identify mode all receivers, group thermostats and the coordinator will flash. Group control thermostat group thermostat group thermostat group thermostat press tick to cancel identify. Identify mode will time ...

  • Page 52

    Group thermostat system has grouping prt please follow step 1 on page 47. When in identify mode all receivers, control group thermostat and the coordinator will flash. Group control thermostat group thermostat group thermostat group thermostat press tick to cancel identify. Identify mode will time o...

  • Page 53

    Press again for 1 second to cancel identify. Identify mode will time out after 10 minutes. To check that the complete system is communicating and has been configured correctly, you can use identify mode. Using identify from the wiring centre will show all products that are connected to your wiring c...

  • Page 54

    Installation - checking system configuration prt prt press tick to cancel identify. Identify mode will time out after 10 minutes. System has no grouping to check that the relevant system is communicating and has been configured correctly, you can use identify mode. Prt prt prt prt please follow step...

  • Page 55

    Installation - replacing product deleting wiring centre from the network. Press for 15 seconds to delete the wiring centre from the network. All led’s will flash momentarily and then the wiring centre will be deleted from the network. All thermostats relating to the wiring centre will need to be rec...

  • Page 56

    Installation - replacing product before replacing any device it must be removed from the zigbee network. Please ensure the zigbee coordinator is also in pairing mode. Note: if replacing a thermostat connected to the wiring centre, you can use the replacement method. Deleting thermostat from the netw...

  • Page 57

    Installation - device parameters device parameters will follow system parameters on first power up. If you need to change device parameters follow the steps below. Please note, your system parameters will be shown first but cannot be edited in this section. To change the system parameters please ref...

  • Page 58

    Installation - device parameters dx function system setting definition default d01 heating 0 pulse width modulation control 1 on-off 0.5 deg c +/- 0.25 deg c 0 2 on-off 1.0 deg c +/- 0.5 deg c d02 room -3.0 to 3.0 temperature offset from temperature deg c measured temperature to 0 deg c offset compe...

  • Page 59

    Installation - device parameters continued dx function system setting definition default d08 frost set point 5-17 deg c required temperature for frost 5 deg temperature protection and holiday mode d09 hour format 0 12 1 1 24 d10 n/a n/a n/a n/a d11 daylight saving 0 off 1 time (dst) 1 on d12 heating...

  • Page 60

    Installation - error codes error code prog non-prog hw 01 comm connection link failure comm connection link failure comm connection link failure 02 comm connection link failure comm connection link failure comm connection link failure 03 floor sensor open floor sensor open - 04 floor sensor short fl...

  • Page 61

    Installation - error codes error code prog non-prog hw 10 wc lost link with hot water timer comm connection link failure comm connection link failure (displayed on all relevant thermostats (displayed on all relevant thermostats (displayed on all relevant thermostats and also hot water timer) and als...

  • Page 62

    Installation - technical detail model vs10rf / vs20rf type electronic programmable room thermostat, digital room thermostat and hot water rf programming modes user selectable for 5/2, all and individual day options program number 1-6 selectable modes party, vacation, program and frost override perma...

  • Page 63

    User guide - setting time and date prt and group control thermostat vs20wrf and vs20brf installer manual 63 user guide it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:38 stron.

  • Page 64

    User guide - setting time and date use left to select 12 hour and right to select 24 hour. Adjust the time using the up or down arrow key. Prt and group control thermostat hour minutes 64 vs20wrf and vs20brf installer manual it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:38 stron.

  • Page 65

    User guide - setting time and date prt and group control thermostat month year day vs20wrf and vs20brf installer manual 65 user guide adjust the year/month/ day using the up or down arrow key. It600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:38 stron.

  • Page 66

    User guide - understanding temperature levels heating highest temperature typically used for early morning and early evening. Typically 21 deg c mid temperature typically used for times of day when you are active around the home typically 19 deg c lower temperature typically used for unoccupied or s...

  • Page 67

    User guide - understanding temperature levels cooling occupied temperature. Typically 22ºc unoccupied temperature typically 40ºc this avoids cooling being active when the property is unoccupied. Evening temperature typically 24ºc your thermostat comes preset for the above temperatures. These can be ...

  • Page 68

    User guide - default heating schedule 21 19 17 12.00 7.00 9.00 17.00 23.00 monday to friday 21 19 17 12.00 8.00 9.00 17.00 23.00 saturday to sunday prt and group control thermostat if using grouping, the schedule from the group control thermostat will be applied to group members. 68 vs20wrf and vs20...

  • Page 69

    User guide - default cooling schedule 22 40 24 12.00 7.00 9.00 17.00 23.00 monday to friday 22 40 24 12.00 8.00 9.00 17.00 23.00 saturday to sunday prt and group control thermostat if using grouping, the schedule from the group control thermostat will be applied to group members. Vs20wrf and vs20brf...

  • Page 70

    User guide - graphics key press once press x amount of times hold for five seconds flashing xx short press to save and long press to save and exit short press to back up 70 vs20wrf and vs20brf installer manual it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:38 stron.

  • Page 71

    User guide - setting required temp levels by setting the low temperature the program schedule will use this as the low setting. The temperature set are applicable to the individual thermostat. Prt, group control thermostat and group thermostat setting the low temperature vs20wrf and vs20brf installe...

  • Page 72

    User guide - setting required temp levels repeat for move back to once temperature levels have been chosen. By setting the low temperature the programs will use this as the low setting. The temperature set are applicable to the individual thermostat. Prt, group control thermostat and group thermosta...

  • Page 73

    User guide – setting the temperature schedule use right and left to select the day of the programs. 5/2 7 days individual if using grouping, the schedule from the group control thermostat will be applied to group members. Vs20wrf and vs20brf installer manual 73 user guide it600 vs20w - installer - u...

  • Page 74

    User guide – setting the temperature schedule adjust the time using the up or down arrow key. Use right and left to select the hi/mid or low temp. 74 vs20wrf and vs20brf installer manual it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:39 stron.

  • Page 75

    User guide – setting the temperature schedule when you set the temperature the schedule will respond to those temperatures see page 71 on how to change repeat through to program 4. If you require a 5th or 6th program enter a time and select your temperature to remove a program out set the time to --...

  • Page 76

    User guide - temporary override use the up or down arrow key to view your program set temperature. The temporary override is applicable to the thermostat being changed only. Use the up or down arrow key to adjust the temperature to the setting you desire. Temporary override allows you to increase th...

  • Page 77

    User guide - temporary override to cancel temporary override press or see below. Prt, group control thermostat and group thermostat confirm the temporary set temperature. Vs20wrf and vs20brf installer manual 77 user guide it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:39 stron.

  • Page 78

    User guide - permanent override to cancel permanent override select see below. Permanent override in a control group thermostat will also affect the group thermostats unless they are removed from the group. See page 64. Move from to use the up or down arrow key to view your set temperature. See page...

  • Page 79

    User guide - party mode the party mode is an option that enables temperature for a period of time you select up to 9hr 50min. Use the right arrow to select the party mode. Use the up arrow to select the hr/min. Press tick to confirm and it will start to count down . Party mode set in a control group...

  • Page 80

    User guide - holiday mode use the right arrow to select the holiday mode. Use the up arrow to select how many days to be off for . Press tick to confirm and it will start the holiday count down. Holiday set in a control group thermostat will also affect group thermostats unless they are removed from...

  • Page 81

    User guide - frost protection use the right arrow to select the frost mode. Use the up arrow to select the frost protection temperature. Press tick to confirm the temperature that has been set to. Frost protection set in a control group thermostat will also affect group thermostats unless they are r...

  • Page 82

    User guide - group thermostat overview when a group thermostat is in it will follow the mode status of the group control thermostat. When a group thermostat is in and the group control thermostat is in or then the group thermostat will follow this mode. Or will be displayed. The group thermostat has...

  • Page 83

    User guide - group thermostat overview the group thermostat has now left the group and is in permanent to adjust the set temperature, please refer to page 71. The group thermostat has now left the group and is in permanent to adjust the set temperature, please refer to page 71. The group thermostat ...

  • Page 84: Mode Selection

    User guide - hot water (optional) mode selection 2 3 mode selection hot water will follow holiday mode from the group control thermostat. Will be displayed. When is selected, the hot water timer will follow the program schedule. See page 86. Hot water will be on once per day. Hot water will be conti...

  • Page 85

    User guide - hot water boost vs20wrf and vs20brf installer manual 85 user guide it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:39 stron.

  • Page 86

    User guide - default hot water schedule 12.00 6.00 8.00 18.00 22.00 on on off off off 12.00 6.00 8.00 18.00 22.00 saturday and sunday monday to friday on on off off off your hot water timer comes preset with the times below. These can be adjusted. See next page. 86 vs20wrf and vs20brf installer manu...

  • Page 87

    User guide - setting hot water times 5/2 7 days individual user guide it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:39 stron.

  • Page 88

    User guide - setting hot water times repeat these steps for programs 88 vs20wrf and vs20brf installer manual it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:39 stron.

  • Page 89

    User guide - setting hot water times vs20wrf and vs20brf installer manual 89 user guide repeat these steps for programs it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:39 stron.

  • Page 90

    Installer notes 90 vs20wrf and vs20brf installer manual it600 vs20w - installer - user manual 011_layout 1 07.07.2014 10:39 stron.

  • Page 91

    Salus controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of five years from the date of installation. Salus controls sole liability for breach of this warranty will be (at its option) to r...

  • Page 92: Salus Controls Plc

    Www.Salus-controls.Com salus controls plc salus house dodworth business park south, whinby road, dodworth, barnsley s75 3sp, uk. Sales: t: +44 (0) 1226 323961 e: sales@salus-tech.Com technical: t: +44 (0) 1226 323961 e: tech@salus-tech.Com for pdf installation guide please go to www.Salus-controls.C...