Samlexpower 100S-12A Instructions Manual - 9 Rectifying Faults
Rectifying faults Sine Wave lnverter
9 Rectifying faults
- P19 -
Fault
Cause
Remedy
No output voltage, LED not
Illuminated
Bad connection between
battery and inverter.
Internal fuses defect.
Check the cables and contact
In this case send the unit
back to supplier.
No output voltage, OVER-
TEMP LED illuminates
The inverter has been over-
heated.
Switch off the inverter and the
power consuming units.
Wait for approx. 5 - 10 min-
Utes and switch on the
inverter only.
Reduce the loading and
ensure a better ventilation for the
inverter.
Then switch back on the
consuming unit.
Overload LED illuminates
Current consumption of the
consuming unit is too high.
Possibly, there is a short cir-
cuit in the consuming unit.
Switch off the inverter and
disconnect the consuming
units.
Switch back on the inverter
only. If the OVERLOAD LED
is off, there is a short circuit at
the consuming unit or the
total load was higher than the
performance specified within
the technical data table.
Check the connecting cable
of the consuming unit for
mechanical damages.
Acoustic signal in case of
loading
Battery voltage too low. In
case of loading battery voltage
falls below 10.7 V resp.
21.4 V.