Samlexpower PST-300-12 Owner's Manual - Section 12 |
40 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 41
seCtIOn 12 |
specifications
MoDeL no.
PSt-300-12
PSt-300-24
oUtPUt
oUTPUTVoLTAGE
120VAC±3%
120VAC±3%
MAXIMUMoUTPUTCURRENT
2.54A
2.54A
oUTPUTfREQUENCY
60Hz±1%
60Hz±1%
TYPEofoUTPUTWAVEfoRM
Pure Sine Wave
Pure Sine Wave
ToTALHARMoNICDISToRTIoNof
oUTPUTWAVEfoRM
<3%
<3%
CoNTINUoUSoUTPUTPoWER
(AtPowerfactor=1)
300 Watts
300 Watts
SURGEoUTPUTPoWER
(AtPowerfactor=1;<1sec)
500Watts
500Watts
PEAKEffICIENCY(Atfullload)
88%
88%
ACoUTPUTCoNNECTIoNS
NEMA5-20RGfCIDuplexoutlets
inPUt
NoMINALDCINPUTVoLTAGE
12V
24V
DCINPUTVoLTAGERANGE
10.5-16.5VDC
21-33VDC
MAXIMUMINPUTCURRENT
40A
20A
DCINPUTCURRENTATNoLoAD
<500mA
<400mA
DCINPUTCoNNECTIoNS
TubularTypeScrewDown
Terminals
TubularTypeScrewDown
Terminals
DiSPLAY
LED
Power,Abnormal
Power,Abnormal
PRotectionS
LoWDCINPUTVoLTAGEALARM
10.5V
21V
LoWDCINPUTVoLTAGESHUTDoWN
10V
20V
HIGHDCINPUTVoLTAGESHUTDoWN
16.5V
33V
SHoRTCIRCUITSHUTDoWN
Yes
Yes
oVERLoADSHUTDoWN
Yes
Yes
GRoUNDfAULTSHUTDoWN
Yes
Yes
oVERTEMPERATURESHUTDoWN
Yes
Yes
REVERSEPoLARITYoNDCINPUTSIDE
Yes
Yes
foRCEDAIRCooLING
TemperatureControlledfan TemperatureControlledfan
coMPLiAnce
SAfETY
Intertek-ETLListed.ConformstoANSI/ULStandard458.
EMI/EMC
fCCPart15(B),ClassB
enViRonMent
oPERATINGTEMPERATURERANGE
0to40˚C
0to40˚C
DIMENSIoNSANDWEIGHTS
(LXWXH),MM
246x146.3x65.5
246x146.3x65.5
(LXWXH),INCHES
9.69x5.76x2.58
9.69x5.76x2.58
KG
1.57
1.57
LBS
3.46
3.46
!
cAUtion! RiSK oF FiRe
Donotreplaceanyvehiclefusewitharatinghigherthanrecommendedby
thevehiclemanufacturer.Thisproductisratedtodraw40Amperesfrom12V