Samlexpower SAM-250-12 Owner's Manual - Section 7 |
18 | SAMLEX AMERICA INC.
INVERTER PARAMETER
SAM-250-12
SAM-450-12
SAM-800-12
input
BATTERy SySTEM VOLTAGE
12 VDC
NOMINAL INPUT VOLTAGE
12.5 VDC
INPUT VOLTAGE RANGE
> 10.8 VDC to < 15.4 VDC
INPUT CURRENT AT CONTINUOUS POWER
22.3A to 24.2A
41.3A to 43.3A
72A to 75A
INPUT CURRENT AT NO LOAD
0.2A to 0.3A
0.25A to 0.35A
0.25A to 0.35A
output
OUTPUT VOLTAGE WAVE FORM
Modified Sine Wave
OUTPUT VOLTAGE
115 VAC +10% / -2%
OUTPUT FREQUENCy
60 Hz ± 5%
OUTPUT POWER, CONTINUOUS (RESISTIVE LOAD)
250W
450W
800W
OUTPUT POWER, SURGE (<1 SEC., RESISTIVE LOAD)
500W
900W
1600W
PEAk EFFICIENCy (AT 50% OF CONTINUOUS POWER)
90%
USB CHARGING PORT
USB 3.0, Connector Type "A": 5 VDC, 2.1A
protectionS
LOW INPUT VOLTAGE ALARM
10.8 VDC. ± 0.3VDC
LOW INPUT VOLTAGE SHUTDOW
10.5 VDC.± 0.3VDC
HIGH INPUT VOLTAGE SHUTDOWN
15.4 VDC.± 0.2VDC
OVERLOAD AND GROUND FAULT SHUT DOWN
yes. Latches in shutdown condition. Manual reset: Switch
OFF the ON/OFF Switch, wait 3 mins & Switch ON again.
OVER TEMPERATURE SHUTDOWN
yes. Auto reset on cooling down.
COOLING FAN
Load controlled:
Switches ON at
8W to 12W
Load controlled:
Switches ON at
35W to 45W
INPUT FUSE: 32V, AUTOMOTIVE TyPE ATC
(INSIDE THE UNIT - NOT USER ACCESSIBLE)
30A
70A (2 x 35A in
parallel)
105A (3 x 35A in
parallel)
connectionS
DC INPUT
M4 Thumb Screw
AC OUTPUT - NO. OF NEMA5-15R
One NEMA5-15R
Outlet
Two NEMA5-15R
Outlets
Two NEMA5-15R
Outlets
GeneraL
OPERATING TEMPERATURE RANGE
0°C to 25°C / 32°F to 77°F at 100% loading;
26°C to 35°C / 78.8°F to 95°F at 80% loading
OPERATING HUMIDITy
< 80%; Non-condensing
NEUTRAL TO CHASSIS BONDING
No. Neutral of the NEMA5-15R AC Outlet is
isolated from the chassis
DIMENSIONS (W x D x H)
mm
DIMENSIONS (W x D x H)
inches
114.4 x 150 x 46
4.5 x 5.9 x 1.8
154 x 151 x 56.5
6.1 x 6.0 x 2.2
180 x 218 x 59
7 x 8.6 x 2.4
WEIGHT
0.42 kg
0.92 lb.
0.6 kg
1.3 lb.
1.32 kg
2.91 lb.