Samlexpower SEC-1245A Owner's Manual - page 8
DEPTH OF DISCHARGE AND BATTERY LIFE
The more deeply a battery is discharged on each cycle, the shorter the battery life. Using
more batteries than the minimum required will result in longer life for the battery bank. A
typical cycle life chart is given at Table 2 below:
Table 2. – Typical Cycle Life Chart
Depth of Discharge Cycle Life
Cycle Life
Cycle Life
% of AH Capacity Group 27 / 31
Group 8D
Group GC2
10
1000
1500
3800
50
320
480
1100
80
200
300
675
100
150
225
550
LOSS OF BATTERY CAPACITY AT LOW TEMPERATURES.
Batteries lose capacity in low temperatures. At 32 º F, a battery will deliver about 70 to
80 % of its rated capacity at 80 º F. If the air temperature near the battery bank is lower
than 80 º F, additional batteries will be needed to provide the same usable capacity. For
very cold climates, an insulated / heated battery compartment is recommended.
SERIES AND PARALLEL CONNECTION OF BATTERIES AND BATTERY
BANKS
When two or more batteries are connected in series, their voltages add up but their AH
capacity remains the same. This series connection is also called a “string”. For example,
when two 12 V, 105 AH batteries are connected in series, it becomes a 24 V, 105 AH
battery. (Positive of the first battery is the positive terminal of the series connection. The
negative of the first battery is connected to the positive of the second battery. The
negative of the second battery is the negative of the series connection)
When two or more batteries or battery “strings” are connected in parallel, their voltages
remain the same but their capacities add up. For example, if two 12 V, 105 AH batteries
are connected in parallel, their voltage remains 12 V but their capacity becomes 105 × 2
= 210 AH (Connect the positive terminal of the first battery to the positive terminal of the
second battery. These paralleled common positive terminals become the positive terminal
of the parallel combination. Connect the negative terminal of the first battery to the
negative terminal of the second battery. These paralleled common negative terminals
become the negative terminal of the parallel combination).
A “bank” of battery may be a single battery or a series / parallel combination of a group
of batteries that is used for a particular DC power system. Two or more independent DC
power systems may use two or more associated independent battery “banks”. For
example, in an RV, one “bank” of battery is used for the vehicle’s Starting , Lighting and
Ignition System. A second “bank” of Deep Cycle Auxiliary Batteries is used for running
other DC loads like inverter etc
It is recommended that the depth of discharge should be limited to 50 %