Samlexpower SEC-1280UL Owner's manual - Section 11 |
28 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 29
seCtIOn 11 |
specifications
PARAMeteR
Sec-1280UL
Sec-2440UL
WIRED REMOTE PANEL
(OPTIONAL)
YES (Model 900-RC)
COOLING
Load Controlled Cooling Fan
ON at 15A
±
1A
OFF at 8A
±
0.5A
Load Controlled Cooling Fan
ON at 8A
±
1A
OFF at 4A
±
0.5A
PROTECTIONS
Overload
Short Circuit
Reverse Polarity
Over Temperature
YES
YES
YES
YES
OUTPUT BANKS
2
OUTPUT CONNECTORS
Terminals with tubular holes (8 mm Dia) and set screw - M8
OPERATING TEMPERATURE
RANGE
0
˚
– 40
˚
C
FUSES - AC INPUT SIDE
(6.3 mm x 32 mm);
Slow Blow / Time Delay:
120 VAC Input
20A / 250V
FUSES, DC OUTPUT SIDE
Automotive Blade Type
e.g. Littelfuse “ATO” Series
32V , 90A
(3 pieces of 30A in parallel)
32V , 45A
(3 pieces of 15A in parallel)
DIMENSIONS: (L x W x H), mm
(L x W x H), inch
381 x 244 x 97
15 x 9.61 x 3.82
WEIGHT, KG.
LbS.
4.1
9.0
SAFETY COMPLIANCE
Intertek – ETL Listed
Conforms to ANSI / UL STD 1564
Certified to CAN / CSA STD C22.2 No. 107.2
EMI COMPLIANCE
FCC Part 15(B), Class A
*notes: The charging voltages shown are applicable at battery temperature of 77°F (25°C)