Maintenance of Type 3372 (120 cm²)
6 Maintenance of Type 3372
(120 cm²)
Fig. 12
If the actuator does function properly, it may
be necessary to replace parts subject to wear
Note:
We recommend the following tools
and resources for maintenance:
−
Lubricant: order no. 8152-0043
−
Thread-locking fluid: order no.
8121-3010
−
Mandrel or hook to remove seals
−
Piece of pipe to mount seals and
plain bearings
−
Torque wrench
Before performing any maintenance work,
the actuator must be removed from the valve.
Î
Detach the electrical and pneumatic con-
nections from the positioner. Remove the
external piping from the positioner to the
top of the actuator with fail-safe action
„actuator stem retracts“ (FE).
6.1 Removing the actuator
The actuator must be dismantled to replace,
for example, damaged seals or plain bear-
ings. A defective diaphragm additionally re-
quires the dismantling of the diaphragm
plate assembly. The following instructions
apply to the standard version.
Iftheactuatorisfittedwithanoptionaltravel
limit, the components for the travel limit must
befirstremovedbeforefollowingtheinstruc-
tions described in the next section. The same
appliesforanactuatorfittedwithmanual
override.
Mark both diaphragm cases (1 and 2) to en-
sure that the pneumatic connections are
mounted correctly later on reassembling the
actuator.
6.1.1 Releasing the spring
preloading
Î
Unscrew and remove the hex nuts (21)
on the short bolts (20) on the diaphragm
casing.
Î
Unthread the hex nuts on the long bolts a
few turns, alternating between them to
gradually release the spring preloading.
6.2 Removing the diaphragm
plate assembly
Î
Liftoffthetopdiaphragmcase(1).
Î
Remove all springs (10) in the actuator
with fail-safe action „actuator stem ex-
tends“ (FA).
Î
Take the diaphragm plate (5) together
with the diaphragm (4) and actuator
stem (7) out of the bottom diaphragm
case (2).
Î
Remove the springs (10) now accessible
in the actuator with fail-safe action „ac-
tuator stem retracts“ (FE).
Î
Liftandtakethediaphragmplateassem-
bly out of the bottom diaphragm case.