Samsung AE090JXYDEH User Manual

Other manuals for AE090JXYDEH: Service Manual, Technical Data Manual, Service Manual
Manual is about: ECO HEATING SYSTEM

Summary of AE090JXYDEH

  • Page 1

    Questions or comments? Country call or visit us online at uk 0330 samsung (7267864) www.Samsung.Com/uk/support eire 0818 717100 www.Samsung.Com/ie/support germany 0180 6 samsung bzw. 0180 6 7267864* (*0,20 €/anruf aus dem dt. Festnetz, aus dem mobilfunk max. 0,60 €/anruf) www.Samsung.Com/de/support ...

  • Page 2

    Mim-e03✴n air to water heat pump -mono control unit user manual imagine the possibilities thank you for purchasing this samsung product. This manual is made with 100% recycled paper. En es fr it pt de db68-05402a-00 ehs_mono- kit_ib_05402a-00_en.Indd 3 2015-03-16 오전 11:51:34.

  • Page 3: Contents

    English-2 features of your air to water heat pump running costs-reduction of up to 32.4% samsung ehs, known for its world class efficiency (12kw floor heating system with cop of 4.51), can reduce 32.4% of your running costs as compared to a gas boiler. High performance at low temperature samsung ehs...

  • Page 4: Safety Precautions

    English-3 01 prep ar ation safety precautions before using your new air to water heat pump, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance. Because the following operating instructions cover ...

  • Page 5: For Installation

    English-4 for installation warning use the power line with the power specifications of the product or higher and use the power line for this appliance only. In addition, do not use an extension line. F f extending the power line may result in electric shock or fire. F f do not use an electric transf...

  • Page 6: For Installation

    English-5 01 prep ar ation this appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line. F f failure to do so may result in electric shock, fire, an explosion, or other problems with the product. F f never plug the power cord into a socke...

  • Page 7: For Power Supply

    English-6 f f our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs. The units’components must be accessible and that can be disassembled in conditions of com...

  • Page 8: For Using

    English-7 01 prep ar ation for using warning if the appliance is flooded, please contact your nearest service center. F f failing to do so may result in electric shock or fire. If the appliance generates a strange noise, a burning smell or smoke, unplug the power plug immediately and contact your ne...

  • Page 9: While It Is Operating.

    English-8 do not touch the circuit breaker with wet hands. F f this may result in electric shock. Do not turn the air to water heat pump off with the circuit breaker while it is operating. F f turning the air to water heat pump off and then on again with the circuit breaker may cause a spark and res...

  • Page 10: Yourself.

    English-9 01 prep ar ation if any foreign substance such as water has entered the appliance, cut the power by unplugging the power plug and turning the circuit breaker off and then contact your nearest service center. F f failing to do so may result in electric shock or fire. Do not attempt to repai...

  • Page 11: Unusual Purposes.

    English-10 do not apply a strong impact to the remote controller and do not disassemble the remote controller. Do not touch the pipes connected with the product. F f this may result in burns or injury. Do not use this air to water heat pump to preserve precision equipment, food, animals, plants or c...

  • Page 12: For Cleaning

    English-11 01 prep ar ation for cleaning warning do not clean the appliance by spraying water directly onto it. Do not use benzene, thinner or alcohol to clean the appliance. F f this may result in discoloration, deformation, damage, electric shock or fire. Before cleaning or performing maintenance,...

  • Page 13: Description of Each Icon

    English-12 description of each icon display ② ① ⑪ ⑩ ⑬ ⑭ ④ ⑤ ⑥ ⑦ ③ ⑧ ⑨ ⑫ led indicator (green: normal / red: need to be checked) on/off button temperature control button • without opening the cover of your wired remote controller, you can turn control kit on or off or set the desired temperature. Not...

  • Page 14

    English-13 01 prep ar ation classification indication function control kit ① control kit operation (heat/cool/auto/outing/silent) ② system temperature (water law temp./indoor temp./ outdoor temp./discharge water temp./hot water temp.) ③ temperature (current/desired) timer ④ timer (daily/weekly/holid...

  • Page 15: Description of Each Control

    English-14 description of each control buttons ③ ① ⑦ ⑧ ④ ② ⑮ ⑨ ⑭ ⑫ ⑬ ⑩ ⑪ ⑥ ⑤ ehs_mono- kit_ib_05402a-00_en.Indd 14 2015-03-16 오전 11:51:37.

  • Page 16

    English-15 01 prep ar ation classification button function basic operation button ① turn control kit on or off ② select operation mode (cool/heat/auto) ③ select desired temperature (discharge water/indoor/hot water) ④ outdoor unit silent operation mode ⑤ select outing mode ⑥ check current temperatur...

  • Page 17: Operating Basic Mode

    English-16 operating basic mode operate basic mode by pressing the [mode] button. Water law control kit will automatically adjust the temperature of discharge water with auto mode for indoor heating. • when “water law” is active, the target supply water temperature will be determined automatically d...

  • Page 18: Dhw Mode

    English-17 02 basic oper ation dhw mode you can adjust temperature of hot water tank by providing hot water. Press the mode button in dhw. F f select (economic), (standard), and (power), (forced) by pressing the mode button in dhw section. • to operate hot water mode, you need to set the hot water f...

  • Page 19: Outing Mode

    English-18 outing mode heating can operate at low temperature while you are out with outing mode. Select outing mode by pressing the outing button. F f will be displayed and outing mode will operate. Cancel press any button on the remote controller. • when pressing the outing button while control ki...

  • Page 20: Checking Current Temperature

    English-19 02 basic oper ation checking current temperature you can check current temperature. Check the current temperature by pressing the view button. F f current temperature can be checked in order of (indoor)  (outdoor)  (discharge water)  (hot water)by pressing the view button. F f the temp...

  • Page 21: Setting Weekly Timer

    English-20 setting weekly timer you can operate or stop a desired mode on the day and time you reserve. 1. Press the timer button. F f (timer) will be displayed and then select 'weekly' among 'daily', 'weekly', or 'holiday' by pressing the [∧]/[∨] button. 2. After pressing the [>] button, select the...

  • Page 22

    English-21 02 basic oper ation 7. After pressing the [>] button, select ’on/off’ timer. F f you can select on or off by repeatedly pressing the [∧]/[∨] button. F f when selecting ‘off’, follow 10 or 11. 8. After pressing the [>] button, select the operation mode. F f it is available only for setting...

  • Page 23

    English-22 setting a holiday with weekly timer you can set a holiday with the weekly timer. The set weekly timer will not function when holiday setting is applied. 1. Press the timer button. F f (timer) is displayed and then select 'holiday' among 'daily', 'weekly', or 'holiday' by pressing the [∧]/...

  • Page 24: Canceling A Weekly Timer

    English-23 02 basic oper ation canceling a weekly timer you can cancel weekly timer function. 1. Press the timer button. F f (timer) is displayed and (weekly) will blink. 2. After pressing the [>] button, select the 'day' you want to cancel. F f select a reserved day by pressing the [∧]/[∨] button. ...

  • Page 25: Setting Daily Timer

    English-24 setting daily timer control kit can operate or stop at the time you reserve every day. (silent mode and dhw mode can be reserved.) the reservation time for silent mode and dhw mode should be different. 1. Press the timer button. F f (timer) will be displayed and then select 'daily' among ...

  • Page 26

    English-25 02 basic oper ation 7. After pressing the [>] button, select the reservation for dhw mode or silent mode. Press the up or down button to select the dhw or silent mode. • you cannot use timer function for hot water mode(economic/standard/ power) when you select the use of hot water functio...

  • Page 27

    English-26 how to set the detailed setting (user setting mode) 1 2 3 4 main menu sub-menu seg used 1. If you want to enter the user set mode, press the user set button. F f you will enter the user set mode, and the ‘main menu’ will be displayed. 2. Refer to the wired remote controller’s user set lis...

  • Page 28

    English-27 03 adv anced oper ation user setting mode main menu sub- menu function seg number default range unit 1 1 all lock 1 0 0-unlock, 1-lock - 2 partial key lock operation on/off key lock 1 0 0-unlock, 1-lock operation selection key lock 2 0 0-unlock, 1-lock temperature setting key lock 3 0 0-u...

  • Page 29

    English-28 setting current time (example) 1. Press the user set button. F f 'main menu' will be displayed and current time can be set by pressing the [∧]/[∨] buttons and selecting no.2. 2. Select the number to set 'year, month, date' in sub-menu by pressing the [>] button. F f you can select 'year, ...

  • Page 30

    English-29 03 adv anced oper ation 8. Select the 'day' you want to set by pressing the [>] button. F f you can select 'day(sun~sat)' by pressing the [∧]/[∨] buttons. 9. Select the 'am/pm' you want to set by pressing the [>] button. F f you can select 'am/pm/ am & pm' by pressing the [∧]/[∨] buttons....

  • Page 31

    English-30 wired remote controller installation initializing your wired remote controller communication 1. Press the esc and delete buttons at the same time for more than 5 seconds. F f the communication of your wired remote controller will be initialized, and the device will search for the control ...

  • Page 32

    English-31 03 adv anced oper ation 2) outdoor unit error f f the address of error, “ao” and error code will be displayed alternately on the remote controller display. 3) wired remote controller error f f the error code will blink at 0.5 second interval on the remote controller display and the addres...

  • Page 33

    English-32 use of wired remote controller installation / service mode use of installation/service mode 1 2 3 4 main menu sub-menu seg used 1. If you want to use the installation/service mode for your wired remote controller, press the set and esc buttons at the same time for more than 3 seconds. F f...

  • Page 34

    English-33 03 adv anced oper ation installation/service mode • 'none' will be displayed for the menu that setting modes don't support. In some cases, the setting may not be possible or it may not be applied though it is set on the unit. • if communication initialization is needed after saving the se...

  • Page 35

    English-34 field specification setting mode of wired remote controller use of field specification setting mode data main menu sub-menu 1. If you want to use the field specification setting mode for your wired remote controller, press the set and [∨] buttons at the same time for more than 3 seconds. ...

  • Page 36

    English-35 03 adv anced oper ation use of field specification checking mode data sub-menu main menu 1. If you want to use the field specification checking mode for your wired remote controller, press the set and [∧] buttons at the same time for more than 3 seconds. 2. Refer to the list of field spec...

  • Page 37: Field Setting Mode

    English-36 field setting mode field setting value (fsv) table • reset the power after changing the field setting value. Note • code 10✴✴ : upper and lower temperature limits of each operation mode of wired remote controller heating(water out, room), cooling(water out, room), dhw(tank) • code 20✴✴ : ...

  • Page 38

    English-37 03 adv anced oper ation • code 30✴✴ : user’s options for domestic hot water(dhw) tank heating 3011 : application of dhw tank in user’s system 302✴ : heat pump variables for tank temp. Control and combination with booster heater 303✴ : booster heater variables for combination with heat pum...

  • Page 39: Field Setting Mode

    English-38 field setting mode • code 40✴✴ : user’s options for heating devices including internal backup heater and external boiler 401✴ : space/dhw heating priority and control variables 402✴ : backup/booster heater priority and control variables 403✴ : additional backup boiler operating variables ...

  • Page 40

    English-39 03 adv anced oper ation • code 5042 [d-00] compressor back up heater booster heater 0 (default) forced off forced off forced off 1 forced off forced off permitted 2 permitted forced off forced off remote controller setting range : code 10✴✴ field setting value main menu & code sub menu fu...

  • Page 41: Field Setting Mode

    English-40 field setting mode water law & room thermostat : code 20✴✴ ts ta h1 h2 c1 c2 #2021/2031 #2022/2032 #2061/2071 #2062/2072 #2011 #2012 #2051 #2052 ts : target temp. Ta : ambient temp. Cooling wl heating wl floor fcu field setting value main menu & code sub menu function description sub code...

  • Page 42

    English-41 03 adv anced oper ation water law for cooling • outdoor air temperature range : lower limit c1(#2051, default 30˚c, range : 25 ~ 35˚c), upper limit c2(#2052, default 40˚c, range : 35 ~ 45˚c) - with this default settings, the water outlet temperature by cooling water law can be changed wit...

  • Page 43: Field Setting Mode

    English-42 field setting mode dhw heating : code 30✴✴ t(c) t u > t hp max t hp max t hp off t hp on t u #3021 #3022 #3023 t(c) t u hp max t hp max t u =t hp off t hp on #3021 #3023 tu : user set temp. T(c) : temp. (celsius) 1 t 0 1 0 1 0 space heating request dhw request dhw operation #3024 #3026 #3...

  • Page 44

    English-43 03 adv anced oper ation field setting value main menu & code sub menu function description sub code default min max step unit dhw code 30✴✴ domestic hot water tank application ✴✴ 11 0(no) 0 1(yes) - - heat pump max temp ✴✴ 21 50 45 50 1 ˚c stop ✴✴ 22 2 2 10 1 ˚c start ✴✴ 23 5 5 20 1 ˚c mi...

  • Page 45: Field Setting Mode

    English-44 field setting mode t 1 0 1 0 1 0 dhw request h/p operation booster operation #3032 #3025 1 0 heating request t hp bh hp t bh off t hp max t hp off t hp on t bh on t u #3023 #3022 #3033 t 00.00 01.00 22.00 23.00 24.00 #3044 #3043 #3045 t u t h booster operation heating request dhw request ...

  • Page 46

    English-45 03 adv anced oper ation booster heater variables for controlling dhw tank • the fsv #3031 should be set to “1(on)”(default) to use booster heater as an additional heat source for dhw tank. • booster heater startup delay timer : in case of dhw request, this timer will delay the operation o...

  • Page 47: Field Setting Mode

    English-46 field setting mode space heating : code 40✴✴ ta #4012 #3034 tu ts dhw by booster heater only dhw by booster heater only field setting value main menu & code sub menu function description sub code default min max step unit heating code 40✴✴ heat pump heating/dhw priority ✴✴ 11 0(dhw) 0 1(h...

  • Page 48

    English-47 03 adv anced oper ation heat pump variables for space heating • fsv #4011 for dhw priority is set to “0(dhw)”(default) as a default. Space heating gets a priority by setting fsv #4011 “1”, but this is only valid when the outdoor temperature is lower than the specified temperature defined ...

  • Page 49: Field Setting Mode

    English-48 field setting mode others : code 50✴✴ field setting value main menu & code sub menu function description sub code default min max step unit others code 50✴✴ outing water out temp for cooling ✴✴ 11 25 5 25 1 ˚c room temp for cooling ✴✴ 12 30 18 30 1 ˚c water out temp for heating ✴✴ 13 15 1...

  • Page 50: Maintaining The Unit

    English-49 04 o thers maintaining the unit maintenance activities • in order to ensure optimal availability of the unit, a number of checks and inspections on the unit and the field wiring have to be carried out at regular intervals, preferably yearly. This maintenance should be carried out by samsu...

  • Page 51: Troubleshooting Tips

    English-50 troubleshooting tips if the unit has some problem to work properly, error codes will be displayed on the wired remote controller. The following table describes the explanation of the error codes. Display explanation wired remote controller temp sensor short or open water inlet temp sensor...

  • Page 52

    English-51 04 o thers communication display explanation communication error between remote controller and the control kit tracking error between remote controller and the control kit memory(eeprom) read/write error(wired remote controller data error) e601, e604 e654 • memory(eeprom) read/write error...

  • Page 53: Troubleshooting Tips

    English-52 troubleshooting tips water pump & flow s/w display explanation flow s/w off error in case of flow s/w off in 30sec during water pump signal is on(starting) in case of flow s/w off in 15sec during water pump signal is on (after starting) flow s/w on error in case of flow s/w on in 10min du...

  • Page 54: Error Codes

    English-53 04 o thers error codes if the unit has some problems and does not work normally, error code is shown on the outdoor unit main pba or lcd of the wired remote controller. Display explanation error source 101 control kit / outdoor unit wire connection error control kit, outdoor unit 162 eepr...

  • Page 55: Error Codes

    English-54 display explanation error source 475 outdoor unit fan2 error outdoor unit 484 pfc overload error outdoor unit 485 input current sensor error outdoor unit 500 ipm is overheated outdoor unit 554 gas leak error outdoor unit 590 inverter eeprom checksum error outdoor unit 601 communication er...

  • Page 56: Product Specification

    English-55 04 o thers product specification type unit ae090jxydeh ae090jxydgh ae120jxydeh ae120jxydgh ae140jxydeh ae140jxydgh ae160jxydeh ae160jxydgh power source - 1Φ, 220~240vac 50hz 3Φ, 380~415vac 50hz 1Φ, 220~240vac 50hz 3Φ, 380~415vac 50hz 1Φ, 220~240vac 50hz 3Φ, 380~415vac 50hz 1Φ, 220~240vac ...