Samsung AF28FVSDA Series User & Installation Manual

Other manuals for AF28FVSDA Series: User & Installation Manual

Summary of AF28FVSDA Series

  • Page 1

    Questions or comments? Country call or visit us online at nigeria 0800-726-7864 www.Samsung.Com/africa_en/support ghana 0800-10077 0302-200077 www.Samsung.Com/africa_en/support cote d’ ivoire 8000 0077 www.Samsung.Com/africa_fr/support senegal 800-00-0077 www.Samsung.Com/africa_fr/support cameroon 7...

  • Page 2

    Af28fvsda series af28fvzda series air conditioner user & installation manual imagine the possibilities thank you for purchasing this samsung product. Db68-03794a(7) en fr pt ar 사우디,인도,나이지리아향 fac memory 냉방_ibim_en_03794a(7).Indd 55 2014-03-12 오전 10:30:04.

  • Page 3

    2 features of your new air conditioner samsung air solution! Cool, clean and refreshing feeling at once cool air : your air conditioner uses air flow direction control which provide direct air flow in hot days and indirect air flow when you are cooled down. Refreshing air : auto mode will provide re...

  • Page 4: Contents

    3 en g lis h contents safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 checking before use . . . . . . . . . . . . . . . ....

  • Page 5: Safety Precautions

    4 safety precautions before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance. If you have any questions, call your nearest contact center or find help and inform...

  • Page 6: For Installation

    5 en g lis h fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed. F f failing to do so may result in electric shock or fire. Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a ...

  • Page 7: Safety Precautions

    6 safety precautions for power supply warning when the circuit breaker is damaged, contact your nearest service center. Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not hook the power line over a metal object, place a heavy object on the power line, insert t...

  • Page 8: For Using

    7 en g lis h for using warning if the appliance is flooded, please contact your nearest service center. F f failing to do so may result in electric shock or fire. If the appliance generates a strange noise, a burning smell or smoke, cut-off the power supply immediately and contact the nearest servic...

  • Page 9: Safety Precautions

    8 safety precautions for using warning do not insert your fingers or foreign substances into the air inlet/outlet of the air conditioner. F f take special care that children do not injure themselves by inserting their fingers into the product. Do not use this air conditioner for long periods of time...

  • Page 10: For Cleaning

    9 en g lis h f f as well as being harmful to humans, it may also result in electric shock, fire or problems with the product. Do not drink the water from the air conditioner. F f the water may be harmful to humans. Do not apply a strong impact to the remote controller and do not disassemble the remo...

  • Page 11: Safety Precautions

    10 safety precautions for cleaning caution take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges. F f to avoid cutting your fingers, wear thick cotton gloves when cleaning it. Do not clean the inside of the air conditioner by yourself. F f for cleanin...

  • Page 12: Checking Before Use

    11 en g lis h checking before use using indoor unit make sure that curtain does not block the air inlet. F f it may decrease cooling performance by blocking air circulation. In cool mode, set the appropriate desired temperature. F f if the desired temperature is too low, it may be harmful for human ...

  • Page 13: Checking Before Use

    12 checking before use auxiliary power switch turn on the auxiliary power switch which is installed separately. (only applicable for outdoor unit with separate power supply) auxiliary power switch (nfb, elb, etc.) • auxiliary power switch is not included in the package. Purchase and install it separ...

  • Page 14

    13 en g lis h checking the name of the parts your air conditioner may slightly look different from illustration depending on the model. Indoor unit • if the support bracket is excessively impacted, it may become damaged. Caution air inlet intake outdoor air remote controller receiver smart sensor(ca...

  • Page 15

    14 checking the name of the parts display cleaning smart sensor operation good'sleep mode air conditioner operation mode current operation mode is displayed. Temperature outdoor unit operation mute virus doctor fan speed timer buttons on control panel on/off button individual control button temperat...

  • Page 16

    15 en g lis h operation with control panel 1. Press the power button to operate the air conditioner. F f the air outlets will open in order with melody sound and the air conditioner will operate with auto mode. Stop press the power button one more time. 2. Press the [ ], [ ] buttons to adjust the de...

  • Page 17

    16 checking the remote controller function may be different depending on the model. F f point the remote controller towards the remote control receiver of the unit. F f when the button is pressed, you will hear ringing or beep sound and transmit indicator ( ) will appear on the remote controller dis...

  • Page 18

    17 en g lis h remote controller display operation mode indicator set temperature/time indicator on/off time indicator fan speed indicator auto low medium high air flow direction indicator low battery indicator transmit indicator ❋ ❋ heat mode will be displayed on the remote controller and reception ...

  • Page 19: Basic Operation

    18 basic operation basic operation is an operation mode that can be selected by pressing the mode button. Auto in auto mode, the air conditioner will automatically set the operation mode in cool/dry/fan mode to provide refreshing air throughout your indoor area. F f in auto mode, the air conditioner...

  • Page 20

    19 en g lis h press the button to turn on the air conditioner. Press the button to set solo/family mode. • solo : select this function if you are alone in the room and save electricity bill. • family : select this function if there are lots of people in the room or require powerful cooling. Family m...

  • Page 21: Turbo Operation

    20 turbo operation turbo function will be helpful to cool your room quickly and effectively. Press the button on the remote controller in the cool mode. Wps wi-fi f f turbo indicator appears on the remote controller display and the air conditioner will operate in turbo function for 30 minutes. Cance...

  • Page 22: Good'Sleep Operation

    21 en g lis h good'sleep operation for a comfortable sleep, the air conditioner will operate in fall asleep  sound sleep  wake up from good’ sleep mode. When the air conditioner is on and in cool mode. Wps wi-fi lighting 1. Press the good'sleep button on the remote controller to select the good'sl...

  • Page 23: Good'Sleep Operation

    22 good'sleep operation temperature and fan speed changes in good'sleep mode 1. Fall asleep mode : provides you with comfortable environment for a good sleep by rapid cooling and hypnagogue expedition breeze. 2. Sound sleep mode : the sound sleep mode adjust temperature and air flow in waves to main...

  • Page 24: Setting The On/off Timer

    23 en g lis h setting the on/off timer you can set the air conditioner to turn on/off automatically at desired time. Setting on timer while the air conditioner is off / off timer while the air conditioner is on. Lighting lighting 1. Press the on timer or off timer button. F f on/off timer indicator ...

  • Page 25: Setting The On/off Timer

    24 setting the on/off timer combining on timer and off timer if the air conditioner is off if the air conditioner is on preset time on on timer is shorter than off timer ex) on timer : 3 hours, off timer : 5 hours - the air conditioner will turn on after 3 hours from the moment you have set the time...

  • Page 26: Smart Sensor Operation

    25 en g lis h smart sensor operation in cool mode, camera on the top of the indoor unit will detect the movement within the indoor and when there is no movement for certain time, air conditioner will adjust the indoor temperature or turn off power automatically. Press the button during cool mode. ❋ ...

  • Page 27: Quiet Operation

    26 quiet operation this function can reduce the noise generated during air conditioner operation. Press the button to select quiet function. Lighting f f icon will appear on the remote controller display. Cancel press the quiet, mode or fan , button once again. You can adjust the desired temperature...

  • Page 28

    27 en g lis h cleaning the air conditioner • make sure to turn off the circuit breaker when cleaning the air conditioner. Caution cleaning the indoor unit f f wipe the surface of the unit with a slightly wet or dry cloth when needed. F f brush away the dust on the narrow gap of air conditioner. • si...

  • Page 29

    28 cleaning the air conditioner cleaning the full hd filter full hd filter filters the big dust of incoming air. Pull out the full hd filter in the arrow direction. F f before pulling out the lower full hd filter, take out the zero filter first. Push the full hd filter to the end in the arrow direct...

  • Page 30

    29 en g lis h cleaning the zero filter zero filter traps small dust particles within the air. It is washable and it can be used semi-permanently. Remove the lower full hd filter. Grasp the handle on the zero filter and remove it by pulling it in the direction of the arrow shown in the figure. Push t...

  • Page 31: Troubleshooting

    30 troubleshooting refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. Problem solution the air conditioner does not work at all. • check power status and then operate the air conditioner again. • switch on the circuit breaker and the...

  • Page 32

    31 en g lis h problem solution remote controller is not working. • check if your batteries are depleted. • make sure nothing is blocking your remote controller sensor. • check whether there are strong lighting apparatus near the air conditioner. Strong light which comes from fluorescent bulbs or neo...

  • Page 33: Troubleshooting

    32 troubleshooting problem solution noise is generated • depending on the status of the air conditioner usage, noise can be heard when refrigerant flow movement changes. It is normal. • crackling sound may occur during the operation of the air conditioner, push the zero filter to the end. Water is d...

  • Page 34: Open Source Announcement

    33 en g lis h open source announcement the software included in this product contains open source software. You may obtain the complete corresponding source code for a period of three years after the last shipment of this product by sending an email to mailto:oss.Request@samsung.Com. It is also poss...

  • Page 35: Safety Precautions

    34 safety precautions carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation. Warning hazards or unsafe practices that may result in severe personal injury or death. Caution ha...

  • Page 36

    35 en g lis h warning f f do not assemble the power cord on your own, use two cables together to extend the cable length or tangle the cable. - bad connection, isolation and over voltage may cause fire or electric shock. F f make sure to turn off the main power when setting up the indoor unit electr...

  • Page 37: Required Tools

    36 required tools general tools ① vacuum pump ② torque wrench ③ pipe cutter ④ reamer ⑤ pipe bender ⑥ spirit level ⑦ screw driver ⑧ spanner ⑨ drill ⑩ l wrench ⑪ measuring tape tools for test operations ① thermometer ② resistance meter ③ electroscope 사우디,인도,나이지리아향 fac memory 냉방_ibim_en_03794a(7).Indd ...

  • Page 38

    37 en g lis h choosing the installation location indoor unit f f install the unit at a place close to the wall facing the outside as it is necessary to perform piing connection with the outdoor unit. - it is effective to install the unit at the place where air flow is not blocked and the cool air ca...

  • Page 39

    38 indoor/outdoor unit installation diagram maximum allowable piping elevation 10m or less 6m or less install s-trap for every 6m maximum allowable piping length 20m or less outdoor unit 50cm or more 30c m o r mo re 50cm or more air guide (not provided by manufacturer ) 30cm or more 20cm or more no ...

  • Page 40

    39 en g lis h outdoor unit 30 cm or mo re 50cm or more air guide (not provided by manufacturer ) 30cm or more 20cm or more 60cm or m ore 30cm or more outdoor unit leg rubber leg spare space for piping installation space for outdoor unit refer to following examples for wind protection. F f when insta...

  • Page 41: Accessories

    40 accessories indoor unit accessories remote controller fixing bracket for indoor unit batteries remote controller holder m4x16 screws user & installation manual cleaning cloth (micro fiber) outdoor unit accessories rubber leg main power cable indoor/outdoor unit communication cable indoor/outdoor ...

  • Page 42: Connecting Pipes

    41 en g lis h drilling a hole and fixing the indoor unit f f drill a hole with diameter of 60~65mm towards the outside. F f if the indoor unit is installed on unstable ground, it may shake by external force or by children and get knocked down. To prevent these accidents, you must fix the top or back...

  • Page 43: Connecting Pipes

    42 connecting pipes 2. Bend the connection pipe to an appropriate length using a bender depending upon the installation place. 3. Perform pipe bending process. - perform bending of the pipe using the pipe bender which has a specified bending radius. - be sure to take full care to perform bending of ...

  • Page 44

    43 en g lis h f f tightening of connection parts alight the pipes to be connected and tighten the flare nuts with your hands first and then with a torque wrench, tighten it in a direction shown in below illustration. - you can avoid of gas leakage by applying refrigerant oil on the flare connection ...

  • Page 45: Connecting Drain Hose

    44 connecting drain hose 1. Slightly hit the hole, for drain hose, with your hands or hammer. 2. Insulate the drain hose with drain insulation tube and fix it with tape. 3. Make the drain hose to direct downward to establish natural draining. - make sure to check for proper drainage after connection...

  • Page 46: Electrical Work

    45 en g lis h electrical work • the electrical work should be performed by a specialist qualified for the work. • avoid using multi-concent but use rate power supply for air conditioner. (use separate power cable for outdoor unit.) caution wiring standard f f always make sure that the power supply i...

  • Page 47: Electrical Work

    46 electrical work safety information on outdoor unit power supply f f power cable must be hard chloroprene synthetic rubber or better, which is certified with safety certification (60245 ks iec 66). - rated voltage: 450/750v, h07rn-f (60245 ks iec 66) - use cable over 2.5mm 2 (distance : 15m or les...

  • Page 48

    47 en g lis h how to connect your extended power cables f f items to prepare tools crimping plier connection sleeve (mm) insulation tape contraction tube (mm) spec mh-14 20xØ6.5(hxod) width 19mm 70xØ8.0(lxod) shape 1. As shown in the figure, peel off the shields from the rubber/wire of the power cab...

  • Page 49: Electrical Work

    48 electrical work 5. Apply heat to the contraction tube to contract it. Contraction tube 6. After tube contraction work is completed, wrap it with the insulation tape to finish. Insulation tape • in case of extending the electric wire, please do not use a round-shaped pressing socket. - incomplete ...

  • Page 50: Vacuum Pump

    49 en g lis h vacuum pump vacuuming pipe 1. Completely connect the indoor/outdoor unit pipes. 2. Connect the manifold gauge to the service valve port of the low pressure side on the outdoor unit. 3. Execute vacuum pump for over 30 minutes. - if the pipe extension is larger, time of the vacuum pump s...

  • Page 51: Performing Leak Test

    50 performing leak test f f use leak tester or soapsuds on the pipe connection part after performing vacuum pump. Check for leakage check for leakage test part for indoor unit test part for outdoor unit f f before inspecting the leakage, use a torque wrench to close the cap for the service valve.(co...

  • Page 52: Installing The Earth Wire

    51 en g lis h installing the earth wire earthing must be done by the installation specialist for your safety. F f connect grounding electrode and the air conditioner. - perform the earthing work 3 on the outdoor unit earthing terminal. Charging refrigerant 1. Connect the manifold gauge in the low pr...

  • Page 53: Check And Test Operation

    52 check and test operation 1. Supply power to the air conditioner. 2. Turn on the air conditioner. 3. While pressing and holding the set/cancel button on the remote controller, press the power button for 3 seconds to display the temperature of indoor heat exchanger. - write down the displayed tempe...

  • Page 54: Memo

    53 en g lis h memo 사우디,인도,나이지리아향 fac memory 냉방_ibim_en_03794a(7).Indd 53 2014-03-12 오전 10:30:03.