Samsung AF28FVSDA Series User & Installation Manual

Other manuals for AF28FVSDA Series: User & Installation Manual

Summary of AF28FVSDA Series

  • Page 1

    Questions or comments country call or visit us online at indonesia 021-56997777 08001128888 www.Samsung.Com/id/support philippines 1-800-10-7267864 [pldt] 1-800-8-7267864 [globe landline and mobile] 02-4222111 [other landline] www.Samsung.Com/ph/support thailand 0-2689-3232 1800-29-3232 www.Samsung....

  • Page 2

    Af28fvsda series af28fvzda series air conditioner user & installation manual imagine the possibilities thank you for purchasing this samsung product. Db68-03955a-02 en th in vi s-east_memory_ibim_03955a-02_co_en.Indd 3 2014-10-31 오후 1:49:14.

  • Page 3

    2 features of your new air conditioner samsung air solution! Cool, clean and refreshing feeling at once cool air : your air conditioner uses air flow direction control which provide direct air flow in hot days and indirect air flow when you are cooled down. Refreshing air : auto mode will provide re...

  • Page 4: Contents

    3 english contents safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 checking before use . . . . . . . . . . . . . . . . . ...

  • Page 5: Safety Precautions

    4 safety precautions before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance. If you have any questions, call your nearest contact center or find help and inform...

  • Page 6: For Installation

    5 english do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak. F f this may result in elect...

  • Page 7: Safety Precautions

    6 safety precautions for power supply warning when the circuit breaker is damaged, contact your nearest service center. Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not hook the power line over a metal object, place a heavy object on the power line, insert t...

  • Page 8

    7 english do not operate the appliance with wet hands. F f this may result in electric shock. Do not strike or pull the air conditioner with excessive force. F f this may result in fire, injury, or problems with the product. F f importantly, if the support bracket is excessively impacted, it may bec...

  • Page 9: Safety Precautions

    8 safety precautions for using warning do not insert your fingers or foreign substances into the air inlet/outlet of the air conditioner. F f take special care that children do not injure themselves by inserting their fingers into the product. Do not use this air conditioner for long periods of time...

  • Page 10: For Cleaning

    9 english do not spray volatile material such as insecticide onto the surface of the appliance. F f as well as being harmful to humans, it may also result in electric shock, fire or problems with the product. Do not drink the water from the air conditioner. F f the water may be harmful to humans. Do...

  • Page 11: Safety Precautions

    10 safety precautions for cleaning caution take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges. F f to avoid cutting your fingers, wear thick cotton gloves when cleaning it. Do not clean the inside of the air conditioner by yourself. F f for cleanin...

  • Page 12: Checking Before Use

    11 english checking before use using indoor unit mak e sure that curtain does not block the air inlet. F f it may decrease cooling performance by blocking air circulation. In cool mode, set the appropriate desired temperature. F f if the desired temperature is too low, it may be harmful for human bo...

  • Page 13: Checking Before Use

    12 checking before use auxiliary power switch turn on the auxiliary power switch which is installed separately. (only applicable for outdoor unit with separate power supply) auxiliary power switch (nfb, elb, etc.) • auxiliary power switch is not included in the package. Purchase and install it separ...

  • Page 14

    13 english checking the name of the parts your air conditioner may slightly look different from illustration depending on the model. Indoor unit • if the support bracket is excessively impacted, it may become damaged. Caution air inlet intake outdoor air remote controller receiver smart sensor(camer...

  • Page 15

    14 checking the name of the parts display cleaning smart sensor operation good'sleep mode air conditioner operation mode current operation mode is displayed. Temperature outdoor unit operation mute virus doctor fan speed timer buttons on control panel on/off button individual control button temperat...

  • Page 16

    15 english operation with control panel 1. Press the power button to operate the air conditioner. F f the air outlets will open in order with melody sound and the air conditioner will operate with auto mode. Stop press the power button one more time. 2. Press the [ ], [ ] buttons to adjust the desir...

  • Page 17

    16 checking the remote controller function may be different depending on the model. F f point the remote controller towards the remote control receiver of the unit. F f when the button is pressed, you will hear ringing or beep sound and transmit indicator ( ) will appear on the remote controller dis...

  • Page 18

    17 english remote controller display operation mode indicator set temperature/ time indicator on/off time indicator fan speed indicator auto low medium high air flow direction indicator low battery indicator transmit indicator ❋ ❋ heat mode will be displayed on the remote controller and reception so...

  • Page 19: Basic Operation

    18 basic operation basic operation is an operation mode that can be selected by pressing the mode button. Auto in auto mode, the air conditioner will automatically set the operation mode in cool/dry/fan mode to provide refreshing air throughout your indoor area. F f in auto mode, the air conditioner...

  • Page 20

    19 english press the button to turn on the air conditioner. Press the button to set solo/family mode. • solo : select this function if you are alone in the room or want to save your electricity bill. • family : select this function if there are lots of people in the room or require powerful cooling....

  • Page 21: Turbo Operation

    20 turbo operation turbo function will be helpful to cool your room quickly and effectively. Press the button on the remote controller in the cool mode. Wps wi-fi f f turbo indicator appears on the remote controller display and the air conditioner will operate in turbo function for 30 minutes. F f c...

  • Page 22: Good'Sleep Operation

    21 english good'sleep operation for a comfortable sleep, the air conditioner will operate in fall asleep sound sleep wake up from good’ sleep mode. When the air conditioner is on and in cool mode. Wps wi-fi lighting 1. Press the good'sleep button on the remote controller to select the good'sleep mod...

  • Page 23: Good'Sleep Operation

    22 good'sleep operation temperature and fan speed changes in good'sleep mode 1. Fall asleep mode : provides you with a comfortable environment for a good sleep by rapidly cooling your room and releasing a breeze that induces sleep. 2. Sound sleep mode : the sound sleep mode adjust temperature and ai...

  • Page 24: Setting The On/off Timer

    23 english setting the on/off timer you can set the air conditioner to turn on/off automatically at desired time. Setting on timer while the air conditioner is off / off timer while the air conditioner is on. Lighting lighting 1. Press the on timer or off timer button. F f on/off timer indicator wil...

  • Page 25: Setting The On/off Timer

    24 setting the on/off timer combining on timer and off timer if the air conditioner is off if the air conditioner is on preset time on on timer is shorter than off timer ex) on timer : 3 hours, off timer : 5 hours - the air conditioner will turn on after 3 hours from the moment you have set the time...

  • Page 26: Smart Sensor Operation

    25 english smart sensor operation in cool mode, camera on the top of the indoor unit will detect the movement within the indoor and when there is no movement for certain time, air conditioner will adjust the indoor temperature or turn off power automatically. Press the button during cool mode. ❋ ❋ a...

  • Page 27: Quiet Operation

    26 quiet operation this function can reduce the noise generated during air conditioner operation. Press the button to select quiet function. Lighting f f icon will appear on the remote controller display. Cancel press the quiet , mode or fan , button once again. You can adjust the desired temperatur...

  • Page 28: Cleaning The Air Conditioner

    27 english cleaning the air conditioner • make sure to turn off the circuit breaker when cleaning the air conditioner. Caution cleaning the indoor unit f f wipe the surface of the unit with a slightly wet or dry cloth when needed. F f brush away the dust on the narrow gap of air conditioner. • since...

  • Page 29: Cleaning The Air Conditioner

    28 cleaning the air conditioner cleaning the full hd filter full hd filter filters the big dust of incoming air. Pull out the full hd filter in the arrow direction. F f before pulling out the lower full hd filter, take out the zero filter first. Push the full hd filter to the end in the arrow direct...

  • Page 30

    29 english cleaning the zero filter zero filter traps small dust particles within the air. It is washable and it can be used semi-permanently. Remove the lower full hd filter. Grasp the handle on the zero filter and remove it by pulling it in the direction of the arrow shown in the figure. Push the ...

  • Page 31: Troubleshooting

    30 troubleshooting refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. Problem solution the air conditioner does not work at all. • check power status and then operate the air conditioner again. • switch on the circuit breaker and the...

  • Page 32

    31 english problem solution remote controller is not working. • check if your batteries are depleted. • make sure nothing is blocking your remote controller sensor. • check whether there are strong lighting apparatus near the air conditioner. Strong light which comes from fluorescent bulbs or neon s...

  • Page 33: Troubleshooting

    32 troubleshooting problem solution noise is generated • depending on the status of the air conditioner usage, noise can be heard when refrigerant flow movement changes. It is normal. • crackling sound may occur during the operation of the air conditioner, push the zero filter to the end. Water is d...

  • Page 34: Open Source Announcement

    33 english open source announcement the software included in this product contains open source software. You may obtain the complete corresponding source code for a period of three years after the last shipment of this product by sending an email to mailto:oss.Request@samsung.Com. It is also possibl...

  • Page 35: Safety Precautions

    34 safety precautions carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation. Warning hazards or unsafe practices that may result in severe personal injury or death. Caution ha...

  • Page 36

    35 english warning f f do not assemble the power cord on your own, use two cables together to extend the cable length or tangle the cable. - bad connection, isolation and over voltage may cause fire or electric shock. F f make sure to turn off the main power when setting up the indoor unit electrica...

  • Page 37: Required Tools

    36 required tools general tools ① vacuum pump ② torque wrench ③ pipe cutter ④ reamer ⑤ pipe bender ⑥ spirit level ⑦ screw driver ⑧ spanner ⑨ drill ⑩ l wrench ⑪ measuring tape tools for test operations ① thermometer ② resistance meter ③ electroscope s-east_memory_ibim_en_03955a-02_en.Indd 36 2014-10-...

  • Page 38

    37 english choosing the installation location indoor unit f f install the unit at a place close to the wall facing the outside as it is necessary to perform piing connection with the outdoor unit. - it is effective to install the unit at the place where air flow is not blocked and the cool air can b...

  • Page 39

    38 indoor/outdoor unit installation diagram maximum allowable piping elevation 10 m or less 6 m or less install s-trap for every 6 m maximum allowable piping length 20 m or less outdoor unit 50 cm or more 30 cm or mor e 50 cm or more air guide (not provided by manufacturer ) 30 cm or more 20 cm or m...

  • Page 40

    39 english outdoor unit 30 cm or mor e 50 cm or more air guide (not provided by manufacturer ) 30 cm or more 20 cm or more 60 cm or mor e 30 cm or more outdoor unit leg rubber leg spare space for piping installation space for outdoor unit refer to following examples for wind protection. F f when ins...

  • Page 41: Accessories

    40 accessories indoor unit accessories remote controller fixing bracket for indoor unit batteries remote controller holder m4 x 16 screws user & installation manual cleaning cloth (micro fiber) outdoor unit accessories rubber leg main power cable indoor/outdoor unit communication cable indoor/outdoo...

  • Page 42: Connecting Pipes

    41 english drilling a hole and fixing the indoor unit f f drill a hole with diameter of 60~65 mm towards the outside. F f if the indoor unit is installed on unstable ground, it may be shaken by an external force or children, and eventually get knocked down. To prevent these accidents, you must fix t...

  • Page 43: Connecting Pipes

    42 connecting pipes 2. Bend the connection pipe to an appropriate length using a bender depending upon the installation place. 3. Perform pipe bending process. - perform bending of the pipe using the pipe bender which has a specified bending radius. - be sure to take full care to perform bending of ...

  • Page 44

    43 english f f tightening of connection parts alight the pipes to be connected and tighten the flare nuts with your hands first and then with a torque wrench, tighten it in a direction shown in below illustration. - you can avoid of gas leakage by applying refrigerant oil on the flare connection par...

  • Page 45: Connecting Drain Hose

    44 connecting drain hose 1. Slightly hit the hole, for drain hose, with your hands or hammer. 2. Insulate the drain hose with drain insulation tube and fix it with tape. 3. Direct the drain hose downward to establish natural draining. - make sure to check for proper drainage after connection • fix t...

  • Page 46: Electrical Work

    45 english electrical work • the electrical work should be performed by a specialist qualified for the work. • avoid using multi-concent but use rate power supply for air conditioner. (use separate power cable for outdoor unit.) caution wiring standard f f always make sure that the power supply is c...

  • Page 47: Electrical Work

    46 electrical work safety information on outdoor unit power supply f f power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord. (code designation iec:60245 iec 66 / cenelec: h07rn-f ) - rated voltage: 450/750v, h07rn-f (60245 iec 66)...

  • Page 48

    47 english how to connect your extended power cables f f items to prepare tools crimping plier connection sleeve (mm) insulation tape contraction tube (mm) spec mh-14 20 x Ø6.5(h x od) width 19 mm 70 x Ø8.0(l x od) shape 1. As shown in the figure, peel off the shields from the rubber/wire of the pow...

  • Page 49: Electrical Work

    48 electrical work 4. Wrap it with the insulation tape twice and position your contraction tube in the middle of the insulation tape. F f method 1 40 mm insulation tape f f method 2 insulation tape 35 mm 5. Apply heat to the contraction tube to contract it. Contraction tube 6. After tube contraction...

  • Page 50: Vacuum Pump

    49 english vacuum pump vacuuming pipe 1. Completely connect the indoor/outdoor unit pipes. 2. Connect the manifold gauge to the service valve port of the low pressure side on the outdoor unit. 3. Execute vacuum pump for over 30 minutes. - if the pipe extension is larger, time of the vacuum pump shou...

  • Page 51: Performing Leak Test

    50 performing leak test f f use leak tester or soapsuds on the pipe connection part after performing vacuum pump. Check for leakage check for leakage test part for indoor unit test part for outdoor unit f f before inspecting the leakage, use a torque wrench to close the cap for the service valve.(co...

  • Page 52: Installing The Earth Wire

    51 english installing the earth wire earthing must be done by the installation specialist for your safety. F f connect grounding electrode and the air conditioner. Charging refrigerant 1. Connect the manifold gauge in the low pressure side (gas) and press set/cancel, mode, temp + button simultaneous...

  • Page 53: Check and Test Operation

    52 check and test operation 1. Supply power to the air conditioner. 2. Turn on the air conditioner. 3. While pressing and holding the set/cancel button on the remote controller, press the powe r button for 3 seconds to display the temperature of indoor heat exchanger. - write down the displayed temp...

  • Page 54: Memo

    53 english memo s-east_memory_ibim_en_03955a-02_en.Indd 53 2014-10-28 오후 12:01:04.

  • Page 55: Memo

    54 memo s-east_memory_ibim_en_03955a-02_en.Indd 54 2014-10-28 오후 12:01:04.

  • Page 56: Memo

    55 english memo s-east_memory_ibim_en_03955a-02_en.Indd 55 2014-10-28 오후 12:01:04.