Samsung AJ020MCS3CH Installation Manual - page 15
15
English
Installation Pr
oc
edur
e
Step 6 Connecting the refrigerant pipe
ॳâߢߤߢđAƊߥA²
1 Piping outside diameter.
Indoor unit
Out unit
Power
supply Ø,
V, Hz
Outside
diameter
Liquid Gas
७७ߢߢߩࢩߢߢ߫ࢩ
ߢߣߤࢩߢߤߨࢩߢߥߧ७७ AJ020MCS3EH
1,208-
230,60
1/4”
3/8”
A
B
(h) (H)
C
Main power switch
2 Piping length and the height.
1 Room
max
length
3 Room
total max
length
Max height
between
indoor unit &
outdoor unit
Max height
between
indoor
units
Dimension
82.0 ft
164.0 ft
49.2 ft
24.6 ft
Composition
A,B,C
A+B+C
(H)
(h)
Make at least one round:
It will reduce noise and vibration
CAUTION
• 10 ft as minimum pipe length: It will reduce noise and
vibration.
• The appearance of the unit may be different from the
diagram depending on the model.
ॳâߢߤߦđAƊߦA²
1 Piping outside diameter.
Indoor unit
Out unit
Power
supply Ø,
V, Hz
Outside
diameter
Liquid Gas
७७ߢߢߩࢩߢߢ߫ࢩ
ߢߣߤࢩߢߤߨࢩߢߥߧ७७ AJ024MCS4CH
1,208-
230,60
1/4”
3/8”
७७ߢߣߪࢩߢߧߢ७७
1/2”
A
B
(h) (H)
C
D
Main power switch
2 Piping length and the height.
1 Room
max
length
4 Room
total max
length
Max height
between
indoor unit &
outdoor unit
Max height
between
indoor
units
Dimension
82.0 ft
229.7 ft
49.2 ft
24.6 ft
Composition A,B,C,D
A+B+C+D
(H)
(h)
Make at least one round:
It will reduce noise and vibration
CAUTION
• 10 ft as minimum pipe length: It will reduce noise and
vibration.
• The appearance of the unit may be different from the
diagram depending on the model.