SentexSystems CROWN JEWEL Installation Instructions Manual - Appendix 1
Page 20 of 22
Doc. 6001145
Rev B
APPENDIX 1
INSTALLATION PROGRAMMING MENU
•
Each programming command begins with a 2-digit step number, followed by the required data digits, and
ended by the “#” key.
•
The step number tells the Crown Jewel which setting to change, and the digits contain the new value for
that setting.
•
If the step and data are valid, the unit responds with 2 short beeps.
If you do not hear 2 short beeps, the unit did not understand the input.
•
If an error is made during an entry, press the “
∗
“ key to cancel the command.
STEP
PURPOSE
DIGITS
ACCEPTABLE INPUT
00
Exiting Programming Mode
01
Changing the Unit Password
6
02
Verifying the Unit Password
6
03
Creating an Entry Code
4, 5, or 6
4-digit entry code + relay code+time
zone
04
Erasing an Entry Code
4
4-digit entry code
21
Enabling/Disabling Alarm Call
1
0=disable, 1=gate breach only,
2=keypad strikeout, 3=both
22
Setting the Alarm Call Number
up to 11
00=disables the number
23
Setting Main Gate time
up to 3
1 through 250 seconds
24
Setting Auxiliary Relay Time
up to 3
1 through 250 seconds
26
Setting Auxiliary Relay and Status
Configuration
1
0=Control (with exit request),
1=Shunt,
2=Alarm,
3=CCTV (manual),
4=CCTV (instant),
5=Control (with position sense)
27
Setting the Date and Time
11
year + month + day + day of the week +
hour + minute
29
Setting the Rings Before Answer
up to 2
1 through 15 rings
30
Adjusting the Sidetone Balance
generate 45 second tone
31
Restoring Factory Defaults
32
Resetting the Unit
33
Enabling/disabling the No-Telco Mode
1
0=disable, 1=enable
35
Enabling Direct Commands
1
0=disable, 1=local, 2=remote, 3=both
37
Beep Unit Number
38
Setting the Unit Number
2
this unit number + total number of units
43
Overriding Telephone Company Answering
Service
2
43 + delay time in seconds + #
90
Initiate audio communication through Crown
Jewel
91
Cycling the Main Gate
92
Cycling the Auxiliary Relay
93
Latching the Main Gate
94
Latching the Auxiliary Relay
95
Releasing the Main Gate
96
Releasing the Auxiliary Relay
97
Releasing Both Relays
98
Latching the Main Gate Until XXXX
4
ending time
99
Latching the Auxiliary Relay Until XXXX
4
ending time