Sentry Camera TPO4-380 Operational Manual - page 3
Copyright © 2009. All Rights Reserved.
3
REV072909
To adjust the function selector, move the S1 switch (see
previous illustration) to the desired function. After setting the
function selector (S1), set the scan position.
Position Selector S2
Position Definition
6 Zone
A
5 Zone
B
4 Zone
C
3 Zone
D
2 Zone
E
Use a flat tipped screwdriver to rotate the selector to the home
position (default: position 4).
NOTE: This function is only available on security setting 2 and
3. In function setting 3, the position of the camera can set to
one fixed scan zone. In function setting 2, the position selector
defines the home position. This is the preset area the camera
returns to after 10 sec. when the auto tracking camera is
triggered, and the object has moved away. The video terminal
carries the output signal.
2) RELAY
Relay settings determine the camera’s reaction when
externally connected DVR record or an alarm is triggered. In
function setting 1, video recording is set to OFF. In function
setting 2, an alarm trigger sets video recording ON after
panning to the respective zone. After returning to home
position, video recording turns off after a 10 sec. period. In
function setting 3, video recording is set to ON and only
records the preset stationary zone. See examples below.
Example 1:
If S2 is set to Area C, the camera turns ON if the
sensor device is triggered in Area C, but not if an object enters
area A / E.
Example 2:
If S2 is set to zone 5, the camera turns ON when
anyone enters areas A and C, but not area E.
3) LED
After replacing the front cover or selecting a different setting,
the LED flashes for 1 min. before entering standby mode. The
LED flashes when the sensor device is triggered. After an
object is no longer tracked, the LED continues to flash for 10
sec., then enters standby mode.
4) TAMPER
SWITCH
This function is designed to sense unauthorized tampering of
the camera and can be used in conjunction with conventional
motion detection systems. If the power is cut off or the cover is
removed, the tamper switch alarm triggers.
NOTE:
Under normal working conditions, the NC LOOP is
connected. Otherwise, the contacts are disconnected.
Replacing the Front Cover
The installation, wiring, and configuration of settings has been
finished. Follow the instructions as given to replace the front
cover.
1. Align the bottom hook over the locking screw. Ensure the
hook slides into position over the locking screw.
2. Align the LED so it is visible through the LED opening in
the front cover.
3. Snap the front cover back in place.
4. Tighten the screw.
5. Adjust the camera angle.
NOTE:
All steps above must be completed within 1 min. to prevent
trigger of the alarm. Failing to align the LED with the front cover can
result in breakage of the LED leads.
// SPECIFICATIONS ...
Model TPO4-380
Infrared Sensor
Three Dual Elements PIR
Video Signal
1.0Vp-p / 75 Ohms
Camera Viewing Angle
F2.3 / 48°
Position Angle Interval
30°
Viewing Angle Interval
48°
Detectable Speed
0.3~3 m/sec.
Motor Speed
78 RPM
Temperature Adjust
Auto
Monitoring Zone
180°
Detecting Range
Horizontal 12m
Relay Out (NC Loop)
50mA 12V for DVR or Alarm
Tamper Switch (NC Loop)
100mA 12V for Alarm
Power Supply
12V DC
Current
500mA
Operating Temperature
14°F~122°F / -10°C~50°C
Mounting Height
7.87~10.5ft / 2.4~3.2m
Dimensions
3.2”(W) x 5.4”(H) x 2.8”(D)
83(W) x 138(H) x 70(D) mm
Weight
0.40 lbs / 180g
*Specifications are subject to change without notice
// LIST OF COMPONENTS ...
•
One (1) TPI4-380/TPI4-380P Camera with video/power cable
•
One (1) AC Power Adaptor
•
Three (3) Screw Anchors
•
Three (3) Screws
•
One (1) Blutac
•
One (1) Manual
* For any returns, please include all components listed above with
original packaging in Resalable Condition. Absolutely No
Returns
will be accepted if any component is missing/damaged or
if any cable is cut or tampered with.