Setec DRIFTER Owner's Manual - page 12
selected.
•
For some parameters holding pressed the Backlight button will force
a fast or slow increment of its value.
5.
To exit the Parameter Setting mode, do not press any button for at least
15 seconds. When the display returns to its normal appearance, it means
setup mode has been exited.
Parameter
Number
Description
Default
Value
Range
1
Enables water tank sensor 1
1
0 – 1
2
Enables water tank sensor 2
0
0 – 1
3
Enables water tank sensor 3
0
0 – 1
4
Enables waste water tank sensor
1
0 – 1
5
Battery capacity—the rated capacity of
the battery Amphours
100
7 – 999
6
Battery operating temperature in °C
25
20 – +50
Table 1: Setup Parameters
Tank Sensors
If a tank sensor is enabled but no tank sensor is connected, the tank level will be
shown as either full or empty, depending on whether the pump switch is on or off.
By disabling the sensor the tank level is always shown empty.
Battery Capacity
This is the actual capacity of the battery in Amphours.
When a new battery is fitted, set this to the nominal battery capacity (as marked
on the battery); doing this will assist the software in determining the actual
capacity.
As the DRIFTER learns the battery capacity, it will automatically update this
parameter.
Battery Operating Temperature
This is the typical operating temperature of the battery in degrees Celsius. This
helps improve the accuracy of the predicted timeremaining readout .
12