Smartswitch FC-006 Installation Manual

Manual is about: Engine Room Fan Controller

Summary of FC-006

  • Page 1

    1 smart switch technologies fc-006 engine room fan controller installation manual.

  • Page 2

    2 led program switch rotary switch emergency stop switch input oil pressure switch emergency fire stop input. Emergency fire select jumper batt + batt - comms + comms - to keyboard batt + batt - logic power supply + fan s u pply + fan 1 - fan 1 + fan 2 - fan 2 + fan 3 - fan 3 - fan supply - fan su p...

  • Page 3

    3 emergency fire input setup: note: where indicated the link wire must be installed jumper: input setup: emergency fire select jumper this jumper sets the emergency input for either a normally open or normally closed input switch. If the input switch is normally open install the jumper, if normally ...

  • Page 4

    4 oil pressure switch input setup: note: where indicated the link wire must be installed emergency stop input switch: the emergency stop input switch needs to be a normally closed switch going open when activated. Emergency stop switch input switch oil pressure switch switch link setup for clean con...

  • Page 5

    5 lazzarette on / off switch: push to activate fan 3, repeat to deactivate. On led = green off led = red auto switch: pushing this button allows to scroll between auto / off / manual. Fans on / off led: this led will be on (green) only when the engine room fans are actually on and off (red) when the...

  • Page 6

    6 operation for normal mode: (rotary switch in position 0) manual: when switched to manual mode the engine room fans will turn on and stay on until turn off or placed in auto mode. Off: all fans off auto: when placed in auto mode and the engine starts the fans will start after the programmed “fan st...

  • Page 7

    7 programming for normal mode: (see figure 1 for rotary switch and program switch details). Programming the fan start time: (rotary switch to position d) explanation: after the engine is started the fans will turn on, when the “fan start time” is reached. E.G. Fans will start 30 seconds after the en...

  • Page 8

    8 the lazz fan on and off times can be programmed. Lazz on time: (rotary switch to position 4) turn the rotary switch to position 4. Push the program switch (the led will flash for every key push). Each push will increase the on time in increments of 1 minute. Max time = 1 hour. System default = 5 m...

  • Page 9

    9 special mode: (rotary switch in position f) if the rotary switch is in position f the system will operate as follows. Auto mode: when the engine is started both fan one and fan two will start, when the engine is stopped fan two will turn off while fan will run on for the “engine run on time” (whic...

  • Page 10

    10 lazz on time and then turn off. Programming the engine run on time: (rotary switch to position c) turn the rotary switch to position c. Push the program switch (the led will flash for every key push). Each push will increase the on time in increments of 1 minute. Max time = 1 hour. System default...