SMC Networks C(D)U Series Operation Manual - page 5
4/10
φ6
φ10
φ16
φ20
φ25
φ32
Rc1/8
Double acting D type 0. 0125
Single acting T type 0. 0062
0. 025
0. 05
0. 1
0. 2
0. 3
Note 1)
Double-side
Rubber bumper
0. 0015
0. 02
0. 04
0. 10
0. 15
0. 20
1. Specifications
1-1. Specifications
Bore size
Fluid
Port size
Max. operating pressure
Proof pressure
Ambient and operating
fluid temperature
Piston speed
Allowable kinetic energy J
Lubrication
Bumper
Air
M5x0. 8
0. 7Mpa
1. 05MPa
Without switch: -10 to +70 ℃ (No freezing)
With switch: -10 to +60 ℃ (No freezing)
50 to 500mm/s
Non-lube
Double-side rubber bumper
Note 1) For the ø6 single-acting spring extended type (CDU(K)6- *T), only the rod side has the rubber bumper.
Note 2) No load: Rod retracted.
+1. 0
0
± 0.8°
± 0.5°
Reed auto switch D-A9*
Solid state auto switch D-M9*
Stroke length tolerance
Note 2)
Non-rotating accuracy of the rod
Allowable rotational torque(Nm)
Auto switch(Option)
Min. operating pressure
(Mpa
φ6
φ10, φ16 φ20, φ25, φ32
Single rod
C(D)U*-*D
0.12
0.06
0.05
Double rod
C(D)UW*-*D
0.15
0.10
0.08
Single acting
Single rod
C(D)U*-*S, T
0.2
0.15
0.13
Single rod
C(D)UK*-*D
0.15
0.10
0.08
Double rod
C(D)UKW*-*D
0.18
0.13
0.11
Single acting
Single rod
C(D)UK*-*S, T
0.23
0.18
0.16
Tube I.D. (mm)
Model
)
Double acting
Double acting
Standard
Non-rotating type
1-2. Theoretical Force
a) Double acting single rod type [C(D)U(K)*-*D]
(N
0. 3
0. 5
0. 7
OUT
28. 3
8.49
14.2
19.8
IN
21. 2
6.36
10.6
14.8
OUT
78. 5
23.6
39.3
55
IN
66. 0
19.8
33
46
OUT
201
60.3
101
141
IN
172
51.6
86
121
OUT
314
94.2
157
220
IN
264
79.2
132
185
OUT
491
147
246
344
IN
412
124
206
288
OUT
804
241
402
563
IN
691
207
346
454
Pressure receiving
area(mm
2
)
Operating pressure Mpa
ø6
ø10
Bore
size
)
.2
(mm)
Rod
O.D.
(mm)
Operating direction
ø16
3
4
6
φ32
12
φ20
8
φ25
10