Programmable heating cycle
This setting allows the length of a heating cycle to be adjusted.
To activate this programmable heating cycle setting, the ther-
mostat should be in Day mode and the user must press and
hold down the (+) and (-) buttons for 20 seconds. Note that the
SET icon will blink after 3 seconds, but you must hold down the
buttons until SEC appears at the bottom of the screen. Then,
release the buttons. It is important to keep the two buttons
pressed down to avoid switching to the Lock, Fan or Celcius/
Fahrenheit modes. After the 20 seconds, the three top figures
will display the number of seconds for a heating cycle and
SEC will be displayed at the bottom of the screen. It’s possible
to adjust the lenght of the heating cycle from 480 seconds
(8 minutes) to 900 seconds (15 minutes).
Heating power indicator
The level of power used to maintain the temperature at the set
point is expressed as a percentage indicated by the number of
bars in the thermometer displayed. The heating power used is
displayed as follows:
4 bars = 75% to 100%
3 bars = 50% to 75%
2 bars = 25% to 50%
1 bar = 1% to 25%
0 bar = no heat
The bars show the ratio between the time heating cycle is ON
and the total time of the heating cycle programmed by the user.
When Fan mode is ON, heating cycle is 15 minutes (see fan
mode section).
Frost-free warning
The Snowflake icon is displayed when the temperature set point
is between 37°F (3°C) and 41°F (5°C). A minimum temperature
will be maintained to ensure frost control. Please note that when
the word ‘OFF’ is displayed, the ‘frost-free’ minimum tempera-