SVS-Vistek svs11002 User Manual

Other manuals for svs11002: User Manual
Manual is about: SVCam “HR” series

Summary of svs11002

  • Page 1

    U sers m anual svcam “hr” series svs8050, svs11002 and svs16000 gigabit ethernet “gige” line digital progressive area scan camera version 1.4.6 rev17 last update 05.07.2010

  • Page 2

    Users manual area scan cameras svsgige page 2 users manual –svs11002 and svs16000 © svs-vistek gmbh contact: svs-vistek gmbh mühlbachstraße 20 82229 seefeld/obb. Germany tel. +49-(0)8152-99 85-0 www.Svs-vistek.Com service contact: e-mail: service@svs-vistek.Com.

  • Page 3: Index

    Users manual area scan cameras svsgige page 3 users manual –svs11002 and svs16000 © svs-vistek gmbh index content 1 introduction ...................................................................................................6 2 pinout and installation ...............................................

  • Page 4

    Users manual area scan cameras svsgige page 4 users manual –svs11002 and svs16000 © svs-vistek gmbh 13.1.1 sensors:..................................................................................33 13.1.2 cosmetic specs ........................................................................33 13....

  • Page 5

    Users manual area scan cameras svsgige page 5 users manual –svs11002 and svs16000 © svs-vistek gmbh 16.11.8 decoding 12 bit images.............................................................67 16.11.9 adjusting tap balance automatically ............................................67 16.11.10 distri...

  • Page 6: Svs-Vistek

    Users manual area scan cameras svsgige page 6 users manual –svs11002 and svs16000 © svs-vistek gmbh svs-vistek 1 introduction thank you for purchasing a svs-vistek product. Svs-vistek stands for reliable competence and customer oriented solutions in the field of professional machine vision systems. ...

  • Page 7

    Users manual area scan cameras svsgige page 7 users manual –svs11002 and svs16000 © svs-vistek gmbh 2 pinout and installation warning the ccd camera is built with cmos-lsi circuits. All internal electronics in the camera are sensitive to high voltage or electrostatic discharge. The camera can be des...

  • Page 8

    Users manual area scan cameras svsgige page 8 users manual –svs11002 and svs16000 © svs-vistek gmbh 8 out2 (ttl level) 9 in3+, 10 in3- (rs422 level) 11 out3+, 2 out3- (rs422 level) hr10a-7p-4pb (mating connector hr10a-7r-pb) 1 vin+ (10 to 25vdc) 2 vin- (gnd) 3 in0 (ttl level) 4 out0 (ttl level) 2.4 ...

  • Page 9

    Users manual area scan cameras svsgige page 9 users manual –svs11002 and svs16000 © svs-vistek gmbh if you don’t follow this, a significantly reduced data transmission rate is observed. Also the loss of data can appear. 2.6 hardware install camera in the desired location. You can use the ¼“ tripot a...

  • Page 10

    Users manual area scan cameras svsgige page 10 users manual –svs11002 and svs16000 © svs-vistek gmbh the camera puts out data automaticly. The framerate can be adjusted.  triggered, external exposure control if you want to trigger the camera and determine the exposure time by the pulse width of exs...

  • Page 11

    Users manual area scan cameras svsgige page 11 users manual –svs11002 and svs16000 © svs-vistek gmbh 2.8 led signals svcam- camera status signals:  no connection with network cable (yellow slow)  allotment of the network address (yellow quick)  network address allotted (yellow)  connected with a...

  • Page 12

    Users manual area scan cameras svsgige page 12 users manual –svs11002 and svs16000 © svs-vistek gmbh 3.2 adjusting tcp/ip resp. Network settings if the live image is not displayed as shown before, this is most often caused by inappropriate network settings. In this case the camera’s network settings...

  • Page 13

    Users manual area scan cameras svsgige page 13 users manual –svs11002 and svs16000 © svs-vistek gmbh 3.3.1 network address assignment the main components of a network address are the ip (internet protocol) address and the network mask. The usually applied network mask “255.255.255.0” for small netwo...

  • Page 14

    Users manual area scan cameras svsgige page 14 users manual –svs11002 and svs16000 © svs-vistek gmbh 3.3.2 persistent network address assignment open the dialog by selecting “network settings” in the context menu that comes up when right-clicking on an entry in the discovery dialog: all settings in ...

  • Page 15

    Users manual area scan cameras svsgige page 15 users manual –svs11002 and svs16000 © svs-vistek gmbh note: for intel pro/1000 cards the settings should be adjusted as follows: flow control: generate interrupt throttling rate: minimal jumbo frames: adjust to maximal value all svcam-gige cameras suppo...

  • Page 16

    Users manual area scan cameras svsgige page 16 users manual –svs11002 and svs16000 © svs-vistek gmbh connecting a svs gige camera to an average notebook will not allow for operating the camera at highest framerate but only on lower framerates. 3.3.5 connecting multiple cameras to a pc multiple gige ...

  • Page 17

    Users manual area scan cameras svsgige page 17 users manual –svs11002 and svs16000 © svs-vistek gmbh when using svcapture as the controlling application, the “multicast” checkbox has to be checked in the device discovery dialog before opening a camera. It is important to enter a suitable maximal pac...

  • Page 18: 4 Windows X64 Support

    Users manual area scan cameras svsgige page 18 users manual –svs11002 and svs16000 © svs-vistek gmbh after selecting the multicast camera in the camera list of the discovery dialog the ok button can be clicked or the camera entry can be double clicked in order to connect to the already running image...

  • Page 19

    Users manual area scan cameras svsgige page 19 users manual –svs11002 and svs16000 © svs-vistek gmbh a “discovery” dialog will open and will display all available cameras in the network after a short time of discovery. Cameras that become available or unavailable in the network will cause the list t...

  • Page 20: 5 Camera Settings Dialog

    Users manual area scan cameras svsgige page 20 users manual –svs11002 and svs16000 © svs-vistek gmbh 5 camera settings dialog double clicking into the image area or selecting the “camera settings” entry in the “camera” menu brings up a settings dialog that allows for accessing the various camera set...

  • Page 21

    Users manual area scan cameras svsgige page 21 users manual –svs11002 and svs16000 © svs-vistek gmbh 5.1.1 camera in the camera panel the following information is queried from the camera and displayed:  model name : svszzzzxyge  manufacturer name : svs-vistek  serial number  device version  use...

  • Page 22

    Users manual area scan cameras svsgige page 22 users manual –svs11002 and svs16000 © svs-vistek gmbh  software triggered and using pc the frame rate is determined by the number of software trigger pulses generated inside the pc per time. With each “software pulse” the camera will readout a frame. T...

  • Page 23

    Users manual area scan cameras svsgige page 23 users manual –svs11002 and svs16000 © svs-vistek gmbh h2 x v2 x: vertical 2 x and horizontal 2 x at the same time; resolution: horizontal x ½, vertical x ½, sensitivity is 4 x, pixel frequency is halved, max. Frame rate is almost doubled. “no binning” s...

  • Page 24

    Users manual area scan cameras svsgige page 24 users manual –svs11002 and svs16000 © svs-vistek gmbh 5.5.1 offset dark level offset adjustment is possible. When 8 bit are transmitted it can be changed from 0 to 255. Please note that factory adjustment is optimized for s/n ratio and sensitivity. You ...

  • Page 25: 5.9

    Users manual area scan cameras svsgige page 25 users manual –svs11002 and svs16000 © svs-vistek gmbh when switched to “once”, captured images will be checked for tap balance and in case of a deviation, new left/right gain factors will be determined and be sent to the camera. As soon as a balance is ...

  • Page 26: 6 Saving Images To Disk

    Users manual area scan cameras svsgige page 26 users manual –svs11002 and svs16000 © svs-vistek gmbh 5.10 persistence the buttons in the persistence panel allow for saving and restoring all settings:  save to eeprom  restore from eeprom  factory defaults  close 6 saving images to disk the live i...

  • Page 27: 7 Assigning Io Lines

    Users manual area scan cameras svsgige page 27 users manual –svs11002 and svs16000 © svs-vistek gmbh 7 assigning io lines if a camera supports io settings then the input and output lines can be arbitrarily assigned to actual data lines. (hr and eco family) the following outputs are available:  out0...

  • Page 28

    Users manual area scan cameras svsgige page 28 users manual –svs11002 and svs16000 © svs-vistek gmbh the following input lines are available:  in0 (only in hr family, not for eco family)  in1  in2  in3  in_rs232 the input lines can be connected to the following signal drains:  uart_in  trigge...

  • Page 29

    Users manual area scan cameras svsgige page 29 users manual –svs11002 and svs16000 © svs-vistek gmbh displaying a camera’s xml file accordingly to the gige vision standard a gige camera provides for an xml file that defines the camera’s capabilities. Though the xml file will usually be processed by ...

  • Page 30: 10 Other Menu Items

    Users manual area scan cameras svsgige page 30 users manual –svs11002 and svs16000 © svs-vistek gmbh 9 displaying a camera’s feature list a svgige camera provides for a set of features out of a list of all defined features. The “feature list” entry in the “camera” menu allows for getting information...

  • Page 32

    Users manual area scan cameras svsgige page 32 users manual –svs11002 and svs16000 © svs-vistek gmbh 12 firmware update a separate tool called “firmware update tool.Exe” is provided to execute a firmware update depending on serial number a firmware update for the internal camera logic might be usefu...

  • Page 33

    Users manual area scan cameras svsgige page 33 users manual –svs11002 and svs16000 © svs-vistek gmbh 13 technical data an easy logic allows control of the camera by different signals to achieve optimum image quality. 13.1 ccd used/cosmetic issues: 13.1.1 sensors:  kodak kai 11002m 4008 x 2672 pixel...

  • Page 34

    Users manual area scan cameras svsgige page 34 users manual –svs11002 and svs16000 © svs-vistek gmbh 13.2 gain balancing (only “f” + “u” version and if set to 2 tap /”l” version) the output for the “f” + “u” version is as follows: 2 taps are read out and the right half of the image is mirrored. It i...

  • Page 35

    Users manual area scan cameras svsgige page 35 users manual –svs11002 and svs16000 © svs-vistek gmbh 13.2.1 sensor/adc settings for tap balancing a dual-tap camera will usually have the “sensor/adc adjustment” feature enabled which results in a “luminance” panel with additional fields and controls. ...

  • Page 36

    Users manual area scan cameras svsgige page 36 users manual –svs11002 and svs16000 © svs-vistek gmbh 13.3 signal conditioning the analog output of the sensor is conditioned by correlated double sampling (cds) for optimum s/n ratio. Dark level drift is compensated by an “auto zero” amplifier circuit ...

  • Page 37

    Users manual area scan cameras svsgige page 37 users manual –svs11002 and svs16000 © svs-vistek gmbh 13.4.1 tripot mount 13.4.2 views on front, rear and side distance from chip surface to front plate: 11,65mm svs11002 svs16000 bottom view 70mm 45mm front view rear view side view 67mm pixel x = 2452 ...

  • Page 38: Left

    Users manual area scan cameras svsgige page 38 users manual –svs11002 and svs16000 © svs-vistek gmbh 13.4.3 connectors note that left rj 45 is not yet active (future use for 2 nd gigabit channel) hr10a-10p-1pb (mating connector hr10a-10r-12s) 1 vin- (gnd) 2 vin+ (10 to 25vdc) 3 rxd data to camera (r...

  • Page 39

    Users manual area scan cameras svsgige page 39 users manual –svs11002 and svs16000 © svs-vistek gmbh 13.6 basic electro-optic specifications svs11002 “s” version/12 bit output ccd kai 11002 interline 4008 x 2672 pixel pixel size 9 x 9 µm adc used 14 bit max. 12 available readout frequency 1 x 40 mhz...

  • Page 40

    Users manual area scan cameras svsgige page 40 users manual –svs11002 and svs16000 © svs-vistek gmbh 13.8 basic electro-optic specifications svs11002 “u” version/12 bit output ccd kai 11002 interline 4008 x 2672 pixel pixel size 9 x 9 µm adc used 14 bit max. 12 available readout frequency 2 x 50 mhz...

  • Page 41

    Users manual area scan cameras svsgige page 41 users manual –svs11002 and svs16000 © svs-vistek gmbh 13.9.1 basic electro-optic specifications svs16000 “f” version/12 bit output ccd kai 16000 interline 4872 x 3248 pixel pixel size 7,4 x 7,4 µm adc used 14 bit readout frequency 2 x 30 mhz (2 taps) fr...

  • Page 42

    Users manual area scan cameras svsgige page 42 users manual –svs11002 and svs16000 © svs-vistek gmbh 13.11 environmental issues: 13.11.1 europe the camera is ce tested and the rules of en 50022-2 apply. 13.11.2 usa and canada i. Labeling requirements: this device complies with part 15 of the fcc rul...

  • Page 43

    Users manual area scan cameras svsgige page 43 users manual –svs11002 and svs16000 © svs-vistek gmbh 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 400 500 600 700 800 900 1000 wavelength [nm] r e la ti v e re sp o n se color version wavelength [nm ] r e la tiv e re sp o n se 0.0 0.2 0.4 0.6 0.8 1.0 40...

  • Page 44

    Users manual area scan cameras svsgige page 44 users manual –svs11002 and svs16000 © svs-vistek gmbh 13.13 comments on color version if you have purchased a color version (e.G. Svszzzcxge) of this camera, please note the following: in all electrical terms the camera is identical to the black and whi...

  • Page 45

    Users manual area scan cameras svsgige page 45 users manual –svs11002 and svs16000 © svs-vistek gmbh 5.1. Warranty terms standard products warranty and adjustment. Seller warrants that the article to be delivered under this order will be free from detects in material and workmanship under normal use...

  • Page 47

    Users manual area scan cameras svsgige page 47 users manual –svs11002 and svs16000 © svs-vistek gmbh 14.1 problem: a camera does not appear in the discovery dialog solutions: click on “refresh” in order to repeat the discovery action. Disconnect and reconnect the camera’s power cable and repeat the ...

  • Page 48

    Users manual area scan cameras svsgige page 48 users manual –svs11002 and svs16000 © svs-vistek gmbh problem: lmage is present but distorted: solution: try different operation mode. Like if triggered gives bad results try “free running” mode and reduce frame rate to minimum half possible one. Check ...

  • Page 49

    Users manual area scan cameras svsgige page 49 users manual –svs11002 and svs16000 © svs-vistek gmbh 15 appendix b – basic timing for different operation modes 15.1 free running a frame is readout automatically. There is no need to trigger the camera in order to get data. The enclosed software allow...

  • Page 50: Svgige Api

    Users manual area scan cameras svsgige page 50 users manual –svs11002 and svs16000 © svs-vistek gmbh 16 appendix c: sdk description for camera control svgige api gige vision camera software development kit (sdk) version: 1.4.18.42 date: 2009-09-24.

  • Page 51: 16.1

    Users manual area scan cameras svsgige page 51 users manual –svs11002 and svs16000 © svs-vistek gmbh 16.1 overview the gige vision standard is an award-winning specification for connecting cameras to computers by a gigabit ethernet cable. That type of connection is well suited for transferring the h...

  • Page 52: Development Environments

    Users manual area scan cameras svsgige page 52 users manual –svs11002 and svs16000 © svs-vistek gmbh 16.4 development environments the svgige sdk has been designed as dll components (one api and two transport layers: filter driver and winsock based) which export c-style functions to be used by appli...

  • Page 53: Documentation

    Users manual area scan cameras svsgige page 53 users manual –svs11002 and svs16000 © svs-vistek gmbh 16.6 documentation the svgige api documentation is provided in the following documents:  svgige sdk user guide.Pdf – an overview documentation (this document)  svgige.H – a header file with inline ...

  • Page 54: 16.8

    Users manual area scan cameras svsgige page 54 users manual –svs11002 and svs16000 © svs-vistek gmbh registering for a camera container client, a camera or a streaming channel respectively. Those handles have to be stored locally and be used in all subsequent function calls to the different areas in...

  • Page 55: 16.9

    Users manual area scan cameras svsgige page 55 users manual –svs11002 and svs16000 © svs-vistek gmbh 16.9 detailed function listing * * 0 - gige dll (implicitly called) * --------------------------------- * isversioncompliantdll() * isloadedgigedll() * getcamera() * * 1 - camera: discovery and bookk...

  • Page 56

    Users manual area scan cameras svsgige page 56 users manual –svs11002 and svs16000 © svs-vistek gmbh * streamingchannel_getpeakdatarate() * * 5 - stream: transfer parameters * ------------------------------- * camera_evaluatemaximalpacketsize() * camera_setstreamingpacketsize() * camera_setinterpack...

  • Page 57

    Users manual area scan cameras svsgige page 57 users manual –svs11002 and svs16000 © svs-vistek gmbh * stream_getmessagedata() * stream_getmessagetimestamp() * stream_releasemessage() * stream_flushmessages() * stream_closeevent() * * 11 - controlling camera: frame rate * ---------------------------...

  • Page 58

    Users manual area scan cameras svsgige page 58 users manual –svs11002 and svs16000 © svs-vistek gmbh * -------------------------------------------- * camera_setacquisitioncontrol() * camera_getacquisitioncontrol() * camera_setacquisitionmode() * camera_setacquisitionmodeandstart() * camera_getacquis...

  • Page 59

    Users manual area scan cameras svsgige page 59 users manual –svs11002 and svs16000 © svs-vistek gmbh * * 19 - controlling camera: image appearance * ----------------------------------------- * camera_getpixeltype() * camera_setpixeldepth() * camera_getpixeldepth() * camera_setwhitebalance() * camera...

  • Page 60: 16.10

    Users manual area scan cameras svsgige page 60 users manual –svs11002 and svs16000 © svs-vistek gmbh * 25 - general functions * ---------------------- * svgige_estimatewhitebalance() * svgige_writeimagetobitmapfile() * * 26 - diagnostics * ---------------- * geterrormessage() * camera_registerforlog...

  • Page 61

    Users manual area scan cameras svsgige page 61 users manual –svs11002 and svs16000 © svs-vistek gmbh.

  • Page 62

    Users manual area scan cameras svsgige page 62 users manual –svs11002 and svs16000 © svs-vistek gmbh.

  • Page 63

    Users manual area scan cameras svsgige page 63 users manual –svs11002 and svs16000 © svs-vistek gmbh.

  • Page 64: 16.11

    Users manual area scan cameras svsgige page 64 users manual –svs11002 and svs16000 © svs-vistek gmbh 16.11 best programming practices in the following a step-by-step procedure will be given how to communicate to a svcam gige camera by a software application. A working application that implements all...

  • Page 65

    Users manual area scan cameras svsgige page 65 users manual –svs11002 and svs16000 © svs-vistek gmbh once an application is done with a camera it needs to close the connection and thus allowing the camera container to release all resources that have been kept occupied in meantime for the active appl...

  • Page 66

    Users manual area scan cameras svsgige page 66 users manual –svs11002 and svs16000 © svs-vistek gmbh the sdk allows for determining the maximal possible network packet size automatically based on “test frames” that are defined in the gige vision specification. Therefore the following function has to...

  • Page 67

    Users manual area scan cameras svsgige page 67 users manual –svs11002 and svs16000 © svs-vistek gmbh imageinfo->sizex = image_getsizex(image); imageinfo->sizey = image_getsizey(image); imageinfo->pixeltype = image_getpixeltype(image); imageinfo->imageid = image_getimageid(image); the newly allocated...

  • Page 68

    Users manual area scan cameras svsgige page 68 users manual –svs11002 and svs16000 © svs-vistek gmbh take multiple images until a final balance is reached. Once a balance is adjusted, the tap balance is finished and the gain factors are not changed anymore. Those gain factors will apply until the ca...

  • Page 69

    Users manual area scan cameras svsgige page 69 users manual –svs11002 and svs16000 © svs-vistek gmbh the connection between the controlling application and the camera is established as usual based on ip addresses. However, a switch has to be specifically instructed for forwarding an image stream als...

  • Page 70

    Users manual area scan cameras svsgige page 70 users manual –svs11002 and svs16000 © svs-vistek gmbh programming interface when opening a camera, an application is supposed to check whether the camera streams already in multicast mode using the function: camera_getmulticastmode() the multicast mode ...

  • Page 71

    Users manual area scan cameras svsgige page 71 users manual –svs11002 and svs16000 © svs-vistek gmbh 16.11.11receiving messages asynchronously an application can receive messages like e.G. “start of transfer” asynchronously in three different ways: 1. By registering an event callback 2. By using a b...

  • Page 72

    Users manual area scan cameras svsgige page 72 users manual –svs11002 and svs16000 © svs-vistek gmbh the above shown default assignment can be set by program as follows: camera_setioassignment(camera,svgige_iomux_out_io_txd,svgige_iomux_in_uart_out); camera_setioassignment(camera,svgige_iomux_out_ua...

  • Page 73

    Users manual area scan cameras svsgige page 73 users manual –svs11002 and svs16000 © svs-vistek gmbh subsequently, data can be sent and received over serial rs232 line using a block size of 512 bytes. If more than 512 bytes have to be sent or received, then those data will be transferred using that ...

  • Page 74

    Users manual area scan cameras svsgige page 74 users manual –svs11002 and svs16000 © svs-vistek gmbh 255 4095 4094 18 17 16 12-bit input 8-bit output 255 1023 1022 6 5 4 10-bit input 8-bit output 7 1021 1020 before uploading/downloading a lut, a check needs to be performed what size of lut is suppor...

  • Page 75

    Users manual area scan cameras svsgige page 75 users manual –svs11002 and svs16000 © svs-vistek gmbh svgige filterdriver installation/de-installation the sdk provides for functionality to install and to de-install a svgige filterdriver: svgige_installfilterdriver(char *pathtodriverpackage, char *fil...

  • Page 76

    Users manual area scan cameras svsgige page 76 users manual –svs11002 and svs16000 © svs-vistek gmbh the user will be informed about a short network interruption: for both variants, the user will be asked for confirming warning dialogs: after some time, the driver will be installed and a message inf...

  • Page 77: -Installation

    Users manual area scan cameras svsgige page 77 users manual –svs11002 and svs16000 © svs-vistek gmbh automated svgige filter driver de -installation please go to the file menu and select “uninstall filter driver” for starting an automated svgige filterdriver de-installation. Before, the filter drive...

  • Page 78

    Users manual area scan cameras svsgige page 78 users manual –svs11002 and svs16000 © svs-vistek gmbh the user will be informed about a short network interruption during de-installation of the filter driver: after some time, a message will inform about successful de-installation: subsequently, a wins...

  • Page 79

    Users manual area scan cameras svsgige page 79 users manual –svs11002 and svs16000 © svs-vistek gmbh manual svgige filterdriver installation 17.1 installation instruction for filter driver installation in order to use the svs gige driver it has to be installed first. The setup will copy the driver t...

  • Page 80

    Users manual area scan cameras svsgige page 80 users manual –svs11002 and svs16000 © svs-vistek gmbh step 3: in the “select network component type” dialog select the service option and click on “add …”.

  • Page 81

    Users manual area scan cameras svsgige page 81 users manual –svs11002 and svs16000 © svs-vistek gmbh step 4: in the “select network service” dialog click on “have disk …” step 5: in the “install from disk” dialog the folder where the driver files are located needs to be navigated to or entered direc...

  • Page 82

    Users manual area scan cameras svsgige page 82 users manual –svs11002 and svs16000 © svs-vistek gmbh step 6: after clicking on ok the “select network service” dialog will display a message that the driver is not digitally signed. Click on ok. Step 7: because the driver not being digitally signed, a ...

  • Page 83

    Users manual area scan cameras svsgige page 83 users manual –svs11002 and svs16000 © svs-vistek gmbh step 8: after confirming the prior dialogs the driver is installed and should show up as a new item in the “lan connections properties” dialog. Step 9: the dialog can be closed and the “gige vision d...

  • Page 84

    Users manual area scan cameras svsgige page 84 users manual –svs11002 and svs16000 © svs-vistek gmbh 18 appendix e setting static link agregation (lag) on intel pro 1000 dual port nic card open network connection dialog open context menu on a server adapter connection and select properties.

  • Page 85

    Users manual area scan cameras svsgige page 85 users manual –svs11002 and svs16000 © svs-vistek gmbh select configure and than teaming tap select teaming tapo.

  • Page 86

    Users manual area scan cameras svsgige page 86 users manual –svs11002 and svs16000 © svs-vistek gmbh choose team with other adapters and press new team press next select both adapters from dual port server adapter choose static link agregation.

  • Page 87

    Users manual area scan cameras svsgige page 87 users manual –svs11002 and svs16000 © svs-vistek gmbh choose static link agregation press finish adapter teaming is done.

  • Page 88

    Users manual area scan cameras svsgige page 88 users manual –svs11002 and svs16000 © svs-vistek gmbh change to advanced tap, set jumbo frames to 16128 byte and press ok back to network connections window, a new connection is created open context menu and open properties..

  • Page 89

    Users manual area scan cameras svsgige page 89 users manual –svs11002 and svs16000 © svs-vistek gmbh choose internet protocol (tcp/ip) and click properties setup ip address and subnet mask and press ok.

  • Page 90

    Users manual – svs11002 and svs16000 © svs-vistek gmbh press ok you are done !!.

  • Page 91

    Users manual area scan cameras svsgige page 91 users manual –svs11002 and svs16000 © svs-vistek gmbh 19 appendix f 19.1 pc and os requirements it is recommended to use a pc with a pentium p4 processor at 3 ghz or higher. The camera is working also on lower frequencies but it might not deliver the fu...

  • Page 92

    Users manual area scan cameras svsgige page 92 users manual –svs11002 and svs16000 © svs-vistek gmbh 20 appendix g 20.1 firmware-update with “gige update tool.Exe“ program note: in order to work with the latest driver and svcapture it might be necessary to update the firmware inside the camera. This...

  • Page 93

    Users manual area scan cameras svsgige page 93 users manual –svs11002 and svs16000 © svs-vistek gmbh step 2: execute svgigeup.Exe step 3: select camera (e.G. 1 and press enter) step 4: wait and follow instructions you are done! After programming it is recommended to start the camera again. This mean...

  • Page 94: For Strobe Use Out1

    Users manual area scan cameras svsgige page 94 users manual –svs11002 and svs16000 © svs-vistek gmbh 21 appendix h basic circuits for hardware interfacing use hardwaretrigger connection on n1 for strobe use out1 ttl input circuit ttl output circuit.

  • Page 95

    Users manual area scan cameras svsgige page 95 users manual –svs11002 and svs16000 © svs-vistek gmbh 21.1 safety instructions • this section contains important information for the operator (user) and/or people around him/her to avoid personal injuries, or property damages against him/her or people a...

  • Page 96

    Users manual area scan cameras svsgige page 96 users manual –svs11002 and svs16000 © svs-vistek gmbh do so invites a fire or an electric shock hazard. In that case, turn the power switch of the system components off immediately and remove the system power cables from the system components connectors...

  • Page 97

    Users manual area scan cameras svsgige page 97 users manual –svs11002 and svs16000 © svs-vistek gmbh if too much amount of light, (= the incoming light amount of 100 times or greater in comparison with standard light) enters ccd image pickup plane, video output might not be obtained. In such a case,...