SVT 2W12120 User manual

Manual is about: SVT-2 Outdoor Station B SVT-2 Outdoor Station C

Summary of 2W12120

  • Page 1

    Svt-2 outdoor station b/c user manual svt-2 outdoor station b 2w12120 svt-2 outdoor station c 2w12120 please read this user manual prior to installing the system, and keep it well for future use..

  • Page 2

    Contents 1.Parts and functions............................................................................................. 1 2.Terminal descriptions .......................................................................................... 1 3.Specification ............................................

  • Page 3

    -1- 1.Parts and functions rain guard camera lens night view led speaker name plate call button microphone 90 mm 176 mm 23 mm 2.Terminal descriptions bus pl s1+ s2+ s- 1 2 on 1 2 on mic adjustment lock control jumper outdoor station code dip main connection port 1 2 3 spk adjustment note: outdoor sta...

  • Page 4

    -2- • lock control jumper: to select the lock type: see 5.2.1 , 5.2.2 • outdoor station code dip: total 4 outdoor stations can be supported,see 6.1 • main connect port: to connect the bus line and the electric locks. • bus: connect to the bus line, no polarity. • pl: external lock power input, conne...

  • Page 5

    -3- 4.2 mounting with rain guard 160-165cm 1 2 1 2 3 4 4.3 placing the name label move the plastic cover away to open the transparent name label cover, insert a name paper, then put the plastic cover back to the panel. Name label 1 2 on.

  • Page 6

    -4- 4.4 adjusting the camera angle 5.1 basic connection use a screwdriver to loose the screw and then adjust the angle of the camera ,then fix the screw back to hold the position of the camera. 5.System wiring and connections - + ac~ svt-2 pc6 1 2 on l1 l2 pl s1+ s2+ s-.

  • Page 7

    -5- 5.2 electric lock connection 5.2.1 door lock controlled with internal power one (1) lock connection two (2) lock connection note: 1. Electric lock of power-on-to-unlock type should be used. 2. The door lock is limited to 12v, and holding current must be less than 250ma. 3. The door lock control ...

  • Page 8

    -6- lock take off the jumper power supply lock take off the jumper power supply lock connect one lock connect two locks 5.2.3 unlock parameter setting (set on indoor monitor) note: 1.The system must be installed properly before proceding to the unlock parameter setting. 2.The parameter will be saved...

  • Page 9

    -7- 5.3 multiple outdoor stations connection 85~260vac svt-2 dps svt-2 ps5 1 2 o n l1 l2 pl s1+ s2+ s- 1 2 o n l1 l2 pl s1+ s2+ s- 1 2 o n l1 l2 pl s1+ s2+ s- 1 2 o n l1 l2 pl s1+ s2+ s- 1 2 on 1 2 on 1 2 on 1 2 on 1# camera id=00 id=10 id=01 id=11 2# camera 3# camera 4# camera svt-2 dbc4 a b c d bu...

  • Page 10

    -8- 5.4.1 basic in-out wiring mode 5.4 multiple indoor monitors connection ac ~ svt-2 pc6.

  • Page 11

    -9- 5.4.2 using svt-2 dbc-4 device - wiring mode hi hi svt-2 dbc-4 a b c d in out svt-2 dbc-4 a b c d in out 85~260ac id=00 1 2 on svt-2 dps svt-2 ps5.

  • Page 12

    -10- 6.Setup 6.2 dip switches settings of indoor monitor 6.1 dip switches settings of outdoor station total 2 bits on the dip switches can be configured.The switches can be modified either before or after installation. Bit state descriptions default setting, id = 0(00), set to the first door station...

  • Page 13

    -11- note: call button a: configure indoor monitors with user codes 0 - 15 call button b: confugure indoor monitors with user codes 16 - 31 a b a each indoor monitor should be assigned with an address in the system. Svt-2 outdoor station b (2w12120): a maximum of 16 indoor monitors can be connected ...

  • Page 14

    -12- 6.3 power supply name description specifications svt-2 pc6 svt-ps5 it provides power for the outdoor stations, indoor monitors and other accessories. It supports a maximum of 32 indoor monitors. It must be used along with a svt-dps device. It supplies power for the outdoor stations, indoor moni...

  • Page 15

    -13- 7.Cable requirements using different cables may affect the maximum distance which the system can reach. When monitor quantity cable usage a b c cat5 cable (1 pair of wire per conductor - must solder the ends) 200 feet 60 meters 14 awg speaker wire (stranded non-shielded) when monitor quantity >...

  • Page 16

    The design and specifications of this user manual can be changed without any notification to the user. All copyright and interpretation rights are reserved to svt innovations inc..