6.Setup
6.2 DIP Switches Settings of Indoor Monitor
6.1 DIP Switches Settings of Outdoor Station
Total 2 bits on the DIP switches can be configured.The switches can be modified either before or after
installation.
Bit state
Descriptions
Default setting, ID = 0(00), set to the first Door Station.
ID = 1(10), set to the second Door Station.
ID = 2(01), set to the third Door Station.
ID = 3(11), set to the fourth Door Station.
1 2
ON
1 2
ON
1 2
ON
1 2
ON
ON(1)
=
OFF(0)
=
ON
ON
There are 3 DIP switches in total. Bits 1 and 2 are reserved and must be on the default position.
The Bit 3 is used to configure the position of each indoor monitor in the connection line. It must be set
to ON if the indoor monitor is in the end of the line, parallel connection, or connected to a SVT-2
DBC-4 module. It must be set to OFF if the indoor monitor is in the middle of the line (daisy chain
connection)
1 2
3
ON
Bit
DIP1&2
Reserved. left to default.
Set to OFF. When the monitor is in the middle of the line in daisy chain connection.
Bit State
Description
DIP3
1 2
3
ON
1 2
3
ON
Set to ON. When the montior is at the end of the line or connected to a SVT-DBC4.