    Svt-mf4 outdoor station d user manual please read this user manual prior to installing the system, and keep it well for future use..

  • Page 2

    Contents 1. Parts and functions.............................................................................................. 1 2. Terminal descriptions .......................................................................................... 2 3. Specifications........................................

  • Page 3

    -1- 1.Parts and functions 3 # description 1 2 led lights 3 high resolution camera 4 built-in speaker 5 call button built-in microphone # description 1 built-in microphone 2 monitor button 3 intercom button 4 door unlock button 5 talk button 6 tft 7” color display 7 built-in speaker 8 talking/ring vo...

  • Page 4

    -2- 2.Terminal descriptions.

  • Page 5: 4.1.

    -3- 160-165 cm 1 2 4.Mounting hatch install into the wall screw hole screws (fix with button case) 3.Specifications outdoor station voltage: dc 14.5v no/nc/com: max. 14.5v 200ma lock power supply: must be used according to lock. Unlocking time: 01 - 99 seconds communication duration: 120s. Communica...

  • Page 6: 4.2.

    -4- screw anchors screws screws (fix with rain cover) rain cover wall hole 4.2. Mounting with the rain guard 4.3. Mounting the indoor monitor.

  • Page 7: 5.1.

    -5- 5.1. Svt-mf4 system with one entrance system wiring and connections 5..

  • Page 8: 5.2.

    -6- 5.2. Svt-mf4 system with two entrances.

  • Page 9: 5.3.

    -7- 5.3. Svt-4 wiring connection 1. Red 2. Blue 3. Yellow 4. White 4-video 1-audio 2-gnd 3-v+ 5.3.1 indoor monitor 1. Red 2. Blue 3. Yellow 4. White 1. Red 2. Blue 3. Yellow 4. White note: do not remove any of the jumpers from the back of the indoor monitors. By removing a jumper or changing its pos...

  • Page 10

    -8-.

  • Page 11

    -9- 5.3.3 electric door lock connection 1. Use the port j3 of the lower module to connect a door lock. 2. The door lock is limited to 14.5v, 120ma. 3. Must use an additional power supply for the door lock. Ensure the power supply is compatible with the door lock specifications..

  • Page 12

    6.Cable requirements b a cable usage a b cat5 cable (must solder the wires together to ensure a good connection). Using different cables may affect the maximum distance the system can reach. 230 feet 70 meters 30 feet 10 meters note: 1. The system expands to a maximum of 2 outdoor stations and 4 ind...

  • Page 13: 7.1

    -11- press the call button at anytime, the indoor monitor will show the view from the front door camera automatically. Press talking button to have communication with the visitor by the front door. The visitor image shown on the monitor 7.1 visitor calls check after pressing the unlocked button, the...

  • Page 14: 7.2

    -12- all indoor monitors ring during the conversation between the outdoor station and the indoor monitor, press button on the main indoor monitor. The indoor monitor press button again to end the conversation. Call transferring from main indoor monitor to extension indoor monitor any indoor monitor ...

  • Page 15: 7.3

    -13- end the call all indoor monitors ring press the talkpress the talking button or hang-upbutton or hang- up the handsetthe handset talk begins any indoor monitor presses button or pick up the handset to talk. 7.3 intercom in the standby mode, press intercom button in any indoor monitor during the...

  • Page 16

    -14- 8.How to set up the user codes svt-mf4 outdoor station d requires the svt remote control for programming. Svt remote control works as a remote access control. It is required to program the svt-4 outdoor station d settings, as registering and deleting fingerprints, unlocking time and fingerprint...

  • Page 17

    -15- in the setting mode: press 0, a di sound heard, and press 7 to hear another di sound. Then enter 6-digits master card number or swipe the master card. After a di sound, the setting is completed. Press * to return to setting mode, and press * again to return to standby mode. Set master card dele...

  • Page 18

    In the setting mode: press 4, a di sound is heard, then enter 2 digits number from 01 to 99 as unlocking time. If a di sound and another di sound are heard, it indicates the unlocking time setting is successful. Press * to return to standby mode. No operation in 30 seconds will return automatically....

  • Page 20