T&C TC30 Installation Instructions Manual

Other manuals for TC30: Instructions For Intallation
Manual is about: CHALET II BURNER KIT

Summary of TC30

  • Page 1

    Part# tc30.Ng06c for use with: model tc30 series c tc30 chalet ii burner kit installation instructions 200411-16 tc30.Ng06c 5056.42907 installer: leave this manual with the appliance. Consumer: retain this manual for future reference. These instructions are supplementary to the installation and oper...

  • Page 2: Contents of Package

    Burner assembly ember material 7 pcs log set hardware package log grate 2 tc30.Ng06c 200411-16 contents of package burner installation 1. Place the keyhole slots in the burner over the two screws located in the fi rebox base. (fig. #1 & 1a) 2. Slide the burner back to engage the screws in the small ...

  • Page 3: Burner/ Grate Installation

    Bulkhead plate 2 screws 4. Secure the electrical bulkhead plate and gasket to the fi rebox. (2 screws) attach the ignition and sensor wires to the module. Red end to the connector marked by the red dot, white end to the connector marked by the white dot fig.#2 & fig.#3 fig. # 2 burner/ grate install...

  • Page 4

    4 tc30.Ng06c 200411-16 pilot supply tube main gas supply tube fig. # 5 5. Attach the pilot and gas supply tubes to the bulk head fi tting and tighten. (fig. # 4) ensure the connections are gas tight. Conceal the spark and sensor wires below the supply tubes. A panel set must now be installed. See in...

  • Page 5: Ember Material

    5 tc30.Ng06c 200411-16 ember material placement log grate glowing embers ember material a large bag of ember material is shipped with the fi replace and needs to be installed on the burner to ensure optimum performance and fl ame appearance. 1. Pull apart the material into ember size pieces (approxi...

  • Page 6

    Fig. #9 fig. # 8 log #2 log #3 6 tc30.Ng06c 200411-16.

  • Page 7

    Fig. #11 fig. #10 log #4 log #5 7 tc30.Ng06c 200411-16.

  • Page 8

    Fig. #13 log #7 note: improper placement of logs will cause sooting on internal parts and glass. Fig. #12 log #6 8 tc30.Ng06c 200411-16.

  • Page 9: Propane Conversion

    Main burner (#48) orifice (5021.3407) minimum rate screw (5005.011) conversion label (5052.52085) for use with model: pour utilise avec du modèle: lp gas/ du gaz lp 12.5 in/wc /12.5 po/c.E. (3.11 kpa) 13.9 in/wc / 13.9 po/c.E. (3.45 kpa) 11.0 in/wc / 11.0 po/c.E. (.95 kpa) # 48 (1.93 mm) max.: 35,00...

  • Page 10

    Hole fig #20 fig #21 minimum rate screw 5. With a ½” wrench remove the natural gas orifi ce (#32) and replace with propane orifi ce (#48)(our part # 5021.3407) (fig. #17) 6. Fully open the primary air shutter. 7. Reinstall the manifold and air defl ector 8. With a 7/16” wrench loosen the pilot head ...

  • Page 11

    12. Replace the minimum rate screw with the one provided in the propane conversion kit supplied with this fi replace. Ensure that the screw is fully installed. (fig. #24) 13. Remove the aluminum cap from the top of the pressure regulator. (fig. #25) 14. Press down on the center post and rotate 90°. ...

  • Page 12: Gas Pressure Check

    1. Remove the plug from the pressure test port. The plug is located between the right side lintel and fi rebox side (bottom port). (fig. #33) 2. Thread the extension test fi tting into the open test port. (fig. #34) 3. Attach a pressure gauge onto the fi tting. 4. When testing is complete remove the...

  • Page 13: Burner Flame Adjustment

    Caution: proper air shutter setting is a must. The fl ame should be just orange and “lazy”. It should never be set to create sooting on internal parts and glass. Caution: burner area may be hot! Turn off the fi replace and allow the unit to cool before proceeding. To adjust: 1. Open and remove windo...

  • Page 14: Replacement Parts

    4 5 6 1a 1b 1c 1d 1e 1f 1g 1h 1i 1j 2a 2b 2c 2d 2e 2f 2g item .......Description ............................................Part no. #1.......... Chalet ii burner assembly ...... Tc30.Ng06c #2.......... 7 pcs log set ................................. 5094.301795 #3.......... Orifice, natural gas (#...

  • Page 15

    15 tc30.Ng06c 200411-16.

  • Page 16

    Printed in canada technical support: 1-250-748-1184 web site: www.Townandcountryfi replaces.Net 2975 allenby rd., duncan, bc v9l 6v8.